Slotted Beam-Column Energy Dissipating Connections: Applicability and Seismic Behavior

被引:5
|
作者
Zhao, Xin [1 ,2 ]
Qi, Ai [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Fujian Jiangxia Univ, Coll Engn, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
SLIT DAMPERS;
D O I
10.1155/2021/5530083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy dissipating joint can effectively strengthen the connection of prefabricated buildings. In the present study, a new slotted mild steel damper was installed at the beam end of the prefabricated structure to form as the energy-dissipating joint of the beam-column. By using ABAQUS software, a finite element (FE) analysis was conducted for the single-story-and-span of the single-frame structure with a slotted damper as energy-dissipating joint. The result shows that the damper was the first to yield in the structure and performed well in energy dissipation, indicating its reasonable design of structure and connection. The energy dissipation mainly occurred at the flange of the variable cross sections, between which beam-ribbed webs ensured the required bearing capacity and stiffness and provided a reliable connection. The hysteretic curves were obtained by analyzing the mechanical properties of the slotted damper under pure bending and pure shearing. In the OpenSees platform, the Steel02 Material model and the twoNodeLink element were used to fit the hysteretic curves; this method was employed for the parametric simulation of the slotted energy dissipation. The dynamic characteristics and seismic response of the controlled structure with slotted energy dissipating joint were also analyzed and compared with those of the uncontrolled structure in the OpenSees platform. The results show that the period of the controlled structure was prolonged and the top story acceleration decreased, indicating its effect in reducing seismic response. The shear-dependent seismic reduction ratio was about 35%, while the drift-dependent seismic reduction ratio was about 10%. The seismic performance of bottom story was better than that of the top story, and the damper has good energy dissipation performance in the bending direction. Some detailed design criteria are put forward and consequences for design on the basis of the performed simulations are shown.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Experimental study on seismic behavior of precast beam-column connections under cyclic loading
    Zhang, Qian
    Wang, Shuo
    Meloni, Marco
    Feng, Jian
    Xu, Jian
    Cai, Jianguo
    Structural Concrete, 2021, 22 (03): : 1315 - 1326
  • [22] Numerical Investigation on the Seismic Behavior of Novel Precast Beam-Column Joints with Mechanical Connections
    Zhuang, Mei-Ling
    Sun, Chuanzhi
    Yang, Zhen
    An, Ran
    Bai, Liutao
    Han, Yixiang
    Bao, Guangdong
    BUILDINGS, 2024, 14 (05)
  • [23] Experimental study of the seismic behavior of cold-formed-tube beam-column connections
    Chu, Yunpeng
    Yao, Yong
    Wang, Ruheng
    Xu, Bin
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2012, 45 (06): : 101 - 109
  • [24] Seismic Behavior of Monolithic Exterior Beam-Column Connections with Unbonded Post-Tensioning
    Kim, Sanghee
    Kang, Thomas H. -K.
    Jung, Donghyuk
    Kwon, Byung Un
    Lee, Dong Joo
    ACI STRUCTURAL JOURNAL, 2023, 120 (06) : 49 - 62
  • [25] Seismic performance of spatial beam-column connections in steel frame
    Xu, Yinglu
    Hao, Jiping
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 180
  • [26] Cyclic Behavior of Beam-Column Connections in Precast Structures
    Meydanli Atalay, Hilal
    Ozden, Sevket
    FRONTIERS IN BUILT ENVIRONMENT, 2021, 7
  • [27] Evaluation on Seismic Performance of Beam-Column Joints of Fabricated Steel Structure with Replaceable Energy-Dissipating Elements
    Li, Yuanqi
    Huang, Binhui
    SUSTAINABILITY, 2022, 14 (06)
  • [28] Bi-directional seismic behavior of steel beam-column connections with outer annular stiffener
    Bai, Yongtao
    Wang, Shuhong
    Mou, Ben
    Wang, Yan
    Skalomenos, Konstantinos A.
    ENGINEERING STRUCTURES, 2021, 227 (227)
  • [29] STUDY ON THE INFLUENCE OF STIFFNESS OF BEAM-COLUMN CONNECTIONS ON THE SEISMIC BEHAVIOR OF COMPOSITE MOMENT RESISTING FRAMES
    Khemis, Ahmed
    Titoum, Messaoud
    Mazoz, Aida
    Louzai, Amar
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2021, 14 (03) : 55 - 67
  • [30] Seismic Behavior of Exterior Beam-Column Connections with High-Strength Materials and Steel Fibers
    Kang, Thomas H-K
    Kim, Sanghee
    Shin, Jae Ho
    LaFave, James M.
    ACI STRUCTURAL JOURNAL, 2019, 116 (04) : 31 - 43