Slotted Beam-Column Energy Dissipating Connections: Applicability and Seismic Behavior

被引:5
|
作者
Zhao, Xin [1 ,2 ]
Qi, Ai [1 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Fujian Jiangxia Univ, Coll Engn, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
SLIT DAMPERS;
D O I
10.1155/2021/5530083
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy dissipating joint can effectively strengthen the connection of prefabricated buildings. In the present study, a new slotted mild steel damper was installed at the beam end of the prefabricated structure to form as the energy-dissipating joint of the beam-column. By using ABAQUS software, a finite element (FE) analysis was conducted for the single-story-and-span of the single-frame structure with a slotted damper as energy-dissipating joint. The result shows that the damper was the first to yield in the structure and performed well in energy dissipation, indicating its reasonable design of structure and connection. The energy dissipation mainly occurred at the flange of the variable cross sections, between which beam-ribbed webs ensured the required bearing capacity and stiffness and provided a reliable connection. The hysteretic curves were obtained by analyzing the mechanical properties of the slotted damper under pure bending and pure shearing. In the OpenSees platform, the Steel02 Material model and the twoNodeLink element were used to fit the hysteretic curves; this method was employed for the parametric simulation of the slotted energy dissipation. The dynamic characteristics and seismic response of the controlled structure with slotted energy dissipating joint were also analyzed and compared with those of the uncontrolled structure in the OpenSees platform. The results show that the period of the controlled structure was prolonged and the top story acceleration decreased, indicating its effect in reducing seismic response. The shear-dependent seismic reduction ratio was about 35%, while the drift-dependent seismic reduction ratio was about 10%. The seismic performance of bottom story was better than that of the top story, and the damper has good energy dissipation performance in the bending direction. Some detailed design criteria are put forward and consequences for design on the basis of the performed simulations are shown.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Seismic behavior of irregular shaped beam-column connections
    Liang, Lili
    Bai, Guoliang
    Ma, Jinfeng
    Jiang, Qiren
    ENGINEERING STRUCTURES, 2023, 297
  • [2] Seismic behavior of weak-axis beam-column connections
    Setia, Saraswati
    Murty, C. V. R.
    Sehgal, V. K.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 873 - 877
  • [3] Seismic performance behavior of beam-column connections in prestressed concrete bridges
    Mo, YL
    Tsai, SP
    Lee, IS
    MATERIALS AND STRUCTURES, 1998, 31 (210) : 411 - 417
  • [4] Seismic performance behavior of beam-column connections in prestressed concrete bridges
    Y. L. Mo
    S. P. Tsai
    I. S. Lee
    Materials and Structures, 1998, 31 : 411 - 417
  • [5] Seismic behavior of plug-in assembly concrete beam-column connections
    Guo, Zhen
    Jia, Xiaoyan
    Ding, Jiahui
    Song, Jun
    Yan, Min
    Liu, Yi
    Li, Fumin
    Zhongguo Kuangye Daxue Xuebao/Journal of China University of Mining and Technology, 2021, 50 (02): : 256 - 264
  • [6] SEISMIC RESPONSE OF BEAM-COLUMN KNEE CONNECTIONS
    KRAMER, DA
    SHAHROOZ, BM
    ACI STRUCTURAL JOURNAL, 1994, 91 (03) : 251 - 260
  • [7] Exterior RC Wide Beam-Column Connections: Effect of Spandrel Beam on Seismic Behavior
    Behnam, Hamdolah
    Kuang, J. S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (04)
  • [8] Seismic Behavior of RC wide beam-column connections under dynamic loading
    Benavent-Climent, A.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2007, 11 (04) : 493 - 511
  • [9] Seismic Behavior of Exterior Beam-Column Connections with Plain Bars and Effects of Upgrade
    Russo, Gaetano
    Pauletta, Margherita
    ACI STRUCTURAL JOURNAL, 2012, 109 (02) : 225 - 233