Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring

被引:47
|
作者
Feng, CH [1 ]
Mitra, S [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
关键词
sample preparation; air analysis; microtraps; monitoring; continuous; volatile organic compounds;
D O I
10.1016/S0021-9673(98)00041-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microtrap is a small diameter sorbent trap packed with adsorbent. In previous studies it has been used as a concentration cum injection device for on-line GC monitoring of trace level organics. The microtrap is prone to breakthrough as it contains a small quantity of adsorbent. A larger diameter trap with more adsorbent reduces breakthrough, but generates broad injection bands that reduce chromatographic resolution, in this paper, we present a two-stage microtrap system. The first, a large diameter retention trap is packed with more sorbent material to increase the breakthrough volume or time. The retention trap is desorbed and the analytes are refocused onto the smaller diameter microtrap referred to as the injection trap. A few seconds delay is provided and then the injection microtrap is desorbed to generate a sharp band injection for GC separation. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [41] On-line color monitoring in continuous textile dyeing
    Kazmi, SZ
    Grady, FL
    Mock, GN
    Hodge, GL
    ISA TRANSACTIONS, 1996, 35 (01) : 33 - 43
  • [42] Monitoring two-stage processes with a profile at the second stage
    Esmaeeli, Hamid
    Sadegheih, Ahmad
    Amiri, Amirhossein
    Doroudyan, Mohammad Hadi
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2017, 46 (03) : 2457 - 2473
  • [43] Investigation of two-stage compression of gas
    V. M. Shmelev
    V. M. Nikolaev
    V. S. Ilyukhin
    D. B. Volov
    High Temperature, 2008, 46 : 77 - 83
  • [44] Investigation of two-stage compression of gas
    Shmelev, V. M.
    Nikolaev, V. M.
    Ilyukhin, V. S.
    Volov, D. B.
    HIGH TEMPERATURE, 2008, 46 (01) : 77 - 83
  • [45] Using a composite membrane for enhanced sensitivity and faster response in on-line membrane extraction microtrap gas chromatography
    Zhang, LH
    Guo, XM
    Mitra, S
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1997, 44 (1-3) : 529 - 539
  • [46] What benefits from two-stage injection?
    Anon
    MER Marine engineers review, 1988, : 12 - 13
  • [47] A two-stage model for wearable device data
    Bai, Jiawei
    Sun, Yifei
    Schrack, Jennifer A.
    Crainiceanu, Ciprian M.
    Wang, Mei-Cheng
    BIOMETRICS, 2018, 74 (02) : 744 - 752
  • [48] A two-stage continuous toxicity monitoring system using recombinant bioluminescent bacteria.
    Gu, MB
    Gil, GC
    Kim, JH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U158 - U158
  • [49] Combustion technology in a novel gas turbine system with steam injection and two-stage combustion
    Zhao, DQ
    Ohno, Y
    Furuhata, T
    Yamashita, H
    Arai, N
    Hisazumi, Y
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2001, 34 (09) : 1159 - 1164
  • [50] Continuous endpoints in Bayesian two-stage designs
    Brutti, Pierpaolo
    De Santis, Fulvio
    Gubbiotti, Stefania
    Sambucini, Valeria
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2016, 26 (05) : 966 - 977