Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring

被引:47
|
作者
Feng, CH [1 ]
Mitra, S [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
关键词
sample preparation; air analysis; microtraps; monitoring; continuous; volatile organic compounds;
D O I
10.1016/S0021-9673(98)00041-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microtrap is a small diameter sorbent trap packed with adsorbent. In previous studies it has been used as a concentration cum injection device for on-line GC monitoring of trace level organics. The microtrap is prone to breakthrough as it contains a small quantity of adsorbent. A larger diameter trap with more adsorbent reduces breakthrough, but generates broad injection bands that reduce chromatographic resolution, in this paper, we present a two-stage microtrap system. The first, a large diameter retention trap is packed with more sorbent material to increase the breakthrough volume or time. The retention trap is desorbed and the analytes are refocused onto the smaller diameter microtrap referred to as the injection trap. A few seconds delay is provided and then the injection microtrap is desorbed to generate a sharp band injection for GC separation. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [31] On-line dyebath monitoring by sequential injection analysis
    Draper, SL
    Beck, KR
    Smith, B
    AATCC REVIEW, 2001, 1 (01) : 24 - 28
  • [32] On-line ultrasonic monitoring of the injection molding process
    Wang, H
    Cao, B
    Jen, CK
    Nguyen, KT
    Viens, M
    POLYMER ENGINEERING AND SCIENCE, 1997, 37 (02): : 363 - 376
  • [33] On-line dyebath monitoring by sequential injection analysis
    Draper, Sara L.
    Beck, Keith R.
    Smith, Brent
    AATCC Magazine, 2001, 1 (01): : 24 - 28
  • [34] On-line ultrasonic monitoring of the injection molding process
    Natl Research Council, Boucherville, Canada
    Polym Eng Sci, 2 (363-376):
  • [35] ON-LINE ELEMENTAL ANALYSIS OF GAS-CHROMATOGRAPHIC EFFLUENTS
    LIEBMAN, SA
    AHLSTRON, DH
    CREIGHTO.TC
    ANALYTICAL CHEMISTRY, 1972, 44 (08) : 1411 - &
  • [36] A Two-Stage Approach for Network Monitoring
    Bai, Linda
    Roy, Sumit
    JOURNAL OF NETWORK AND SYSTEMS MANAGEMENT, 2013, 21 (02) : 238 - 263
  • [37] A Two-Stage Approach for Network Monitoring
    Linda Bai
    Sumit Roy
    Journal of Network and Systems Management, 2013, 21 : 238 - 263
  • [38] A Versatile Solution for Continuous On-line PD Monitoring
    Siddiqui, Bashir Ahmed
    Hilden, Antti
    Pakonen, Pertti
    Verho, Pekka
    2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015,
  • [39] CONTINUOUS ON-LINE TAR MONITORING FOR PROCESS CONTROL
    Borgmeyer, J.
    Neubauer, Y.
    PAPERS OF THE 24TH EUROPEAN BIOMASS CONFERENCE: SETTING THE COURSE FOR A BIOBASED ECONOMY, 2016, : 472 - 474
  • [40] Dual-purpose gas chromatographic injection device for pressurized liquid and gas injection
    Luong, Jim
    Gras, Ronda
    Firor, Roger
    Sieben, Lyndon
    Winniford, Bill
    Cortes, Hernan
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (14) : 2740 - 2748