Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring

被引:47
|
作者
Feng, CH [1 ]
Mitra, S [1 ]
机构
[1] New Jersey Inst Technol, Dept Chem Engn Chem & Environm Sci, Newark, NJ 07102 USA
关键词
sample preparation; air analysis; microtraps; monitoring; continuous; volatile organic compounds;
D O I
10.1016/S0021-9673(98)00041-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microtrap is a small diameter sorbent trap packed with adsorbent. In previous studies it has been used as a concentration cum injection device for on-line GC monitoring of trace level organics. The microtrap is prone to breakthrough as it contains a small quantity of adsorbent. A larger diameter trap with more adsorbent reduces breakthrough, but generates broad injection bands that reduce chromatographic resolution, in this paper, we present a two-stage microtrap system. The first, a large diameter retention trap is packed with more sorbent material to increase the breakthrough volume or time. The retention trap is desorbed and the analytes are refocused onto the smaller diameter microtrap referred to as the injection trap. A few seconds delay is provided and then the injection microtrap is desorbed to generate a sharp band injection for GC separation. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 50 条
  • [1] Helical sorbent microtrap for continuous sampling by a membrane and trap interface for on-line gas chromatographic monitoring of volatile organic compounds
    Ciucanu, I
    Caprita, A
    Chiriac, A
    Barna, R
    ANALYTICAL CHEMISTRY, 2003, 75 (04) : 736 - 741
  • [2] Continuous monitoring of volatile organic compounds in air emissions using an on-line membrane extraction-microtrap-gas chromatographic system
    Mitra, S
    Zhu, NH
    Zhang, X
    Kebbekus, B
    JOURNAL OF CHROMATOGRAPHY A, 1996, 736 (1-2) : 165 - 173
  • [3] Application of on-line membrane extraction microtrap gas chromatography (OLMEM-GC) for continuous monitoring of VOC emission
    Zhu, NH
    Li, ZX
    Mitra, S
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (05) : 393 - 399
  • [4] Application of On-line Membrane Extraction Microtrap Gas Chromatography (OLMEM-GC) for Continuous Monitoring of VOC Emission
    Zhu, Naihong
    Li, Zixian
    Mitra, Somenath
    Journal of Microcolumn Separations, 10 (05): : 393 - 399
  • [5] On-line monitoring of a two-stage anaerobic digestion process using a BOD analyzer
    Liu, J
    Olsson, G
    Mattiasson, B
    JOURNAL OF BIOTECHNOLOGY, 2004, 109 (03) : 263 - 275
  • [6] CONTINUOUS GAS-CHROMATOGRAPHIC MONITORING OF LOW CONCENTRATION SAMPLE STREAMS USING AN ONLINE MICROTRAP
    MITRA, S
    YUN, C
    JOURNAL OF CHROMATOGRAPHY, 1993, 648 (02): : 415 - 421
  • [7] Microtrap modulated flame ionization detector for on-line monitoring of methane
    Thammakhet, C
    Thavarungkul, P
    Brukh, R
    Mitra, S
    Kanatharana, P
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (02) : 243 - 248
  • [8] Microtrap interface for on-line mass spectrometric monitoring of air emissions
    Mitra, S
    Feng, CH
    Zhang, LZ
    Ho, WP
    McAllister, G
    JOURNAL OF MASS SPECTROMETRY, 1999, 34 (05): : 478 - 485
  • [9] On-line signature verification with two-stage statistical models
    Wan, L
    Wan, B
    Lin, ZC
    EIGHTH INTERNATIONAL CONFERENCE ON DOCUMENT ANALYSIS AND RECOGNITION, VOLS 1 AND 2, PROCEEDINGS, 2005, : 282 - 286
  • [10] A SEQUENTIAL VALVE-MICROTRAP INJECTION SYSTEM FOR CONTINUOUS, ONLINE GAS-CHROMATOGRAPHIC ANALYSIS AT TRACE LEVELS
    MITRA, S
    LAI, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1995, 33 (06) : 285 - 289