Parametric study of double-skin facades performance in mild climate countries

被引:63
|
作者
Alberto, Andre [1 ]
Ramos, Nuno M. M. [1 ]
Almeida, Ricardo M. S. F. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn FEUP, CONSTRUCT LFC, Rua Dr Roberto Frias S-N, P-4200465 Oporto, Portugal
[2] Polytech Inst Viseu, Sch Technol & Management, Dept Civil Engn, Campus Politecn Repeses, P-3504510 Viseu, Portugal
关键词
Double-skin facades; Building simulation; Energy efficiency; Overheating; ENERGY PERFORMANCE; AIR-FLOW; BUILDINGS; SIMULATION; SYSTEMS; PERSPECTIVES; VENTILATION;
D O I
10.1016/j.jobe.2017.05.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The application of double-skin facades is an interesting technical solution but, at the same time, highly affected by the climatic conditions of the building location. Southern European countries are characterized by relevant solar gains that play a major role in the performance of double-skin facades. In this work, a parametric study is carried out to systematically assess the impact, in the building performance, of geometry, airflow path, cavity depth, openings area and type of glazing. The study is based in numerical simulations using DesignBuilder/ EnergyPlus, taking advantage of the available CFD module for a better insight on the relevant energy transfer phenomena. It was found that the most important aspect for the efficiency of a double-skin facade is the airflow path and the most efficient geometry was the multi-storey double-skin facade, presenting, in average, 30% less HVAC related energy demands. Internal gains proved to be one of the key factors for the building's energy performance and facade orientation can represent a difference of up to 40% in energy demand between north and southern oriented facades.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 50 条
  • [41] Numerical analyses for scale effect on wind pressure of double-skin facades and its mechanism
    Lou, Wenjuan
    Hu, Weifa
    Wang, Wei
    [J]. Tongji Daxue Xuebao/Journal of Tongji University, 2009, 37 (10): : 1291 - 1295
  • [42] Computational fluid dynamics assessment for the thermal performance of double-skin facades in office buildings under hot climatic condition
    Kim, Daeung Danny
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2021, 42 (01): : 45 - 61
  • [43] Summer thermal comparative experimental study of double plant-skin facades and double skin facades
    Bao, Shenglin
    Zou, Simin
    Li, Baofeng
    Chen, Qiuyu
    Zhao, Mingqiao
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [44] The performance analysis of a double-skin ventilated window integrated with CdTe cells in typical climate regions
    Wang, Chuyao
    Uddin, Md Muin
    Ji, Jie
    Yu, Bendong
    Wang, Jun
    [J]. ENERGY AND BUILDINGS, 2021, 241
  • [45] On the performance of double skin facades in different environmental conditions
    Zerefos, Stelios C.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2007, 26 (04) : 221 - 229
  • [46] Aerodynamic characteristics of tall buildings with porous double-skin facades: State of the art and future perspectives
    Skvorc, Petar
    Kozmar, Hrvoje
    [J]. WIND AND STRUCTURES, 2021, 33 (03) : 233 - 249
  • [47] Evaluating the capability of EnergyPlus in simulating geometrically complex Double-Skin Facades through CFD modelling
    El Ahmar, Salma
    Fioravanti, Antonio
    [J]. ECAADE 2017: SHARING OF COMPUTABLE KNOWLEDGE! (SHOCK!), VOL 1, 2017, : 757 - 764
  • [48] Seismic performance study on a precast double-skin composite wall with circular CFSTs
    Guan, Dongzhi
    Li, Sihao
    Yang, Sen
    Liu, Jiabin
    Guo, Zhengxing
    Wang, Yu
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 200
  • [49] Double-skin facade optimization design for different climate zones in China
    Su, Ziyi
    Li, Xiaofeng
    Xue, Fei
    [J]. SOLAR ENERGY, 2017, 155 : 281 - 290
  • [50] A new type of double-skin facade configuration for the hot and humid climate
    Wong, P. C.
    Prasad, D.
    Behnia, M.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (10) : 1941 - 1945