Double-skin facade optimization design for different climate zones in China

被引:38
|
作者
Su, Ziyi [1 ]
Li, Xiaofeng [1 ,2 ]
Xue, Fei [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-skin facade; Optimization design; Total heat gain; Thermal performance; COLD-WINTER ZONE; THERMAL PERFORMANCE; VENETIAN BLIND; HOT-SUMMER; AIR-FLOW; BUILDINGS; SYSTEMS; HEAT;
D O I
10.1016/j.solener.2017.06.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
While the natural ventilation double-skin facade is a widely-used technology, its thermal performance is not yet fully understood. Hence, this paper investigates the thermal performance and optimization of double-skin facades. Previous studies focused on typical moments or standard days to evaluate the thermal performance of a double-skin facade. The current study adopts a simplified method based on Computational Fluid Dynamics (CFD) to obtain the hourly heat gain and total heat gain of a double skin facade for an entire cooling season. The data is then used to evaluate thermal performance. Finally, based on the total heat gain of the double-skin facade with different structural parameters for an entire cooling season, this paper proposes optimization parameters for different climate zones in China. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:281 / 290
页数:10
相关论文
共 50 条
  • [1] Optimising Design Parameters of a Building-Integrated Photovoltaic Double-Skin Facade in Different Climate Zones in Australia
    Yang, Siliang
    Fiorito, Francesco
    Sproul, Alistair
    Prasad, Deo
    [J]. BUILDINGS, 2023, 13 (04)
  • [2] Apron design for protecting double-skin facade fires
    Chow, Nadia C. L.
    Li, S. S.
    Huang, D. X.
    [J]. FIRE AND MATERIALS, 2015, 39 (03) : 189 - 206
  • [3] Mathematical Modeling of Double-Skin Facade in Northern Area of China
    Zou Huifen
    Fei Yingchao
    Yang Fuhua
    Tang Hao
    Zhang Ying
    Ye Sheng
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2013, 2013
  • [4] Performance assessment of BIPV/T double-skin facade for various climate zones in Australia: Effects on energy consumption
    Yang, Siliang
    Cannavale, Alessandro
    Di Carlo, Aldo
    Prasad, Deo
    Sproul, Alistair
    Fiorito, Francesco
    [J]. SOLAR ENERGY, 2020, 199 : 377 - 399
  • [5] A new type of double-skin facade configuration for the hot and humid climate
    Wong, P. C.
    Prasad, D.
    Behnia, M.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (10) : 1941 - 1945
  • [6] Greenhouse effect in double-skin facade
    Gratia, Elisabeth
    De Herde, Andre
    [J]. ENERGY AND BUILDINGS, 2007, 39 (02) : 199 - 211
  • [7] Natural ventilation in a double-skin facade
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2004, 36 (02) : 137 - 146
  • [8] Double-skin facade in Flotran CFD
    Palko, Milan
    [J]. ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 154 - 159
  • [9] Effect of annual solar radiation on simple facade, double-skin facade and double-skin facade filled with phase change materials for saving energy
    Alqaed, Saeed
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 51
  • [10] Performance evaluation of photovoltaic double-skin facade with forced ventilation in the composite climate
    Preet, Sajan
    Sharma, Manoj Kumar
    Mathur, Jyotirmay
    Chowdhury, Amartya
    Mathur, Sanjay
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 32