Double-skin facade optimization design for different climate zones in China

被引:38
|
作者
Su, Ziyi [1 ]
Li, Xiaofeng [1 ,2 ]
Xue, Fei [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-skin facade; Optimization design; Total heat gain; Thermal performance; COLD-WINTER ZONE; THERMAL PERFORMANCE; VENETIAN BLIND; HOT-SUMMER; AIR-FLOW; BUILDINGS; SYSTEMS; HEAT;
D O I
10.1016/j.solener.2017.06.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
While the natural ventilation double-skin facade is a widely-used technology, its thermal performance is not yet fully understood. Hence, this paper investigates the thermal performance and optimization of double-skin facades. Previous studies focused on typical moments or standard days to evaluate the thermal performance of a double-skin facade. The current study adopts a simplified method based on Computational Fluid Dynamics (CFD) to obtain the hourly heat gain and total heat gain of a double skin facade for an entire cooling season. The data is then used to evaluate thermal performance. Finally, based on the total heat gain of the double-skin facade with different structural parameters for an entire cooling season, this paper proposes optimization parameters for different climate zones in China. (C) 2017 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:281 / 290
页数:10
相关论文
共 50 条
  • [41] Thermal and ventilation performance of a curved double-skin facade model
    Huang, Yi
    Tao, Yao
    Shi, Long
    Liu, Qinggong
    Wang, Yong
    Tu, Jiyuan
    Peng, Qingyuan
    Cao, Cong
    ENERGY AND BUILDINGS, 2022, 268
  • [42] Real-time optimization of a double-skin facade based on lumped modeling and occupant preference
    Park, CS
    Augenbroe, G
    Sadegh, N
    Thitisawat, M
    Messadi, T
    BUILDING AND ENVIRONMENT, 2004, 39 (08) : 939 - 948
  • [43] Energy efficiency of double-skin facade in office buildings of Shanghai
    Sun, Lu
    Jones, Phil J.
    Alexander, Don K.
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1755 - 1762
  • [44] NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FACADE
    Chow, Cheuk Lun
    JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2011, 17 (03) : 371 - 392
  • [45] Calibration of a lumped simulation model for double-skin facade systems
    Park, CS
    Augenbroe, G
    Messadi, T
    Thitisawat, M
    Sadegh, N
    ENERGY AND BUILDINGS, 2004, 36 (11) : 1117 - 1130
  • [46] Modeling and Simulation of Ventilated Double-Skin Facade Using EnergyPlus
    Le, Sha
    Chen, Youming
    Bi, Yuan
    Lu, Xiang
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 241 - 252
  • [47] Program for Quantification Temperature and Aerodynamic Mode of Double-skin Facade
    Palko, Milan
    ADVANCED BUILDING CONSTRUCTION AND MATERIALS 2013, 2014, 855 : 102 - 107
  • [48] Natural ventilation performance of a double-skin facade with a solar chimney
    Ding, WT
    Hasemi, YJ
    Yamada, T
    ENERGY AND BUILDINGS, 2005, 37 (04) : 411 - 418
  • [49] Design optimization and experimental evaluation of photovoltaic double skin facade
    Lee, Chul-sung
    Lee, Hyomun
    Choi, Minjoo
    Yoon, Jongho
    ENERGY AND BUILDINGS, 2019, 202
  • [50] A summer case study on applying ventilated double-skin facade to a building in cold zone of China
    Yang, Hua
    Wan, Qianzhao
    Yang, Bin
    Sun, Chunhua
    Xia, Guoqiang
    Wang, Jiao
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 1682 - 1685