This paper presents the study of a novel scintillation detector based on standard microfabrication techniques. It consists of a fine pitch array of hollow waveguides filled with a liquid scintillator and optically coupled to photodetectors. The detector has been fabricated by patterning the SU-8 photoresist on silicon wafers. Experimental studies have been performed by exciting the liquid scintillator contained in the SU-8 waveguides with electrons. The scintillation light produced was read out by an external photodetector. The results obtained with this set-up demonstrate the concept of microfluidic scintillation detection and are very encouraging for future developments.
引用
收藏
页码:1347 / +
页数:2
相关论文
共 50 条
  • [31] SU-8 Polymer Enclosed Microchannels with Interconnect and Nanohole Arrays as an Optical Detection Device for Biospecies
    Westwood, S. M.
    Gray, B. L.
    Grist, S.
    Huffman, K.
    Jaffer, S.
    Kavanagh, K. L.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5652 - +
  • [32] Synthesis of Metal/SU-8 Nanocomposites through Photoreduction on SU-8 Substrates
    Huang, Yan-Jun
    Chang, Wen-Huei
    Chen, Yi-Jui
    Lin, Chun-Hung
    NANOMATERIALS, 2023, 13 (11)
  • [33] Polymerization optimization of SU-8 photoresist and its applications in microfluidic systems and MEMS
    Zhang, J
    Tan, KL
    Hong, GD
    Yang, LJ
    Gong, HQ
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2001, 11 (01) : 20 - 26
  • [34] An injection micromixer fabricated by improved SU-8 processing for biochemical microfluidic systems
    Liu, Changgeng
    Ling, Zhong-geng
    Lian, Kun
    Goettert, Jost
    Hormes, Josef
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112
  • [35] Smart SU-8 Pillars Implemented in a Microfluidic Bioreactor for Continuous Measurement of Glucose
    Talaei, S.
    Frey, O.
    Psoma, S.
    van der Wal, P. D.
    de Rooij, N. F.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 448 - 451
  • [36] Microgripping force measuring device based on SU-8 microcantilever sensor
    Zhang, Ran
    Chu, Jinkui
    Guan, Le
    Li, Shuangliang
    Min, Jian
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2014, 13 (01):
  • [37] Optical waveguide device realised using two SU-8™ layers
    Ansel, Y
    Gindele, F
    Scheurer, J
    Schmitz, F
    2002 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS, CONFERENCE DIGEST, 2002, : 123 - 124
  • [38] A microfluidic device for thermal particle detection
    Vutha, Ashwin Kumar
    Davaji, Benyamin
    Lee, Chung Hoon
    Walker, Glenn M.
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 17 (05) : 871 - 878
  • [39] A microfluidic device for thermal particle detection
    Ashwin Kumar Vutha
    Benyamin Davaji
    Chung Hoon Lee
    Glenn M. Walker
    Microfluidics and Nanofluidics, 2014, 17 : 871 - 878
  • [40] Surface Stability of SU-8 Film for Accurate Biopotential Detection
    Noguchi, Yuta
    Kawai, Akira
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2012, 25 (06) : 719 - 722