Constrained Active Fault Detection and Control

被引:42
|
作者
Puncochar, Ivo [1 ,2 ]
Siroky, Jan [1 ,2 ]
Simandl, Miroslav [1 ,2 ]
机构
[1] Univ W Bohemia, Fac Sci Appl, Dept Cybernet, Plzen 30614, Czech Republic
[2] Univ W Bohemia, Fac Sci Appl, European Ctr Excellence NTIS, Plzen 30614, Czech Republic
关键词
Fault detection; optimal control; optimal input design; SYSTEMS; DESIGN;
D O I
10.1109/TAC.2014.2326274
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The technical note introduces a constrained optimization approach to active fault detection and control. Detection and control aims can be expressed either as a part of an objective function or as a constraint. Five principal formulations of active fault detection and control problem are proposed and investigated in the technical note. Three formulations are focused on alternative detection and control aims combinations while the other formulations represent marginal cases that outline a relationship to the well know fields of optimal control and active fault detection. The underlying difficulty of the optimal solution is discussed and a suboptimal solution is proposed that makes use of nonlinear programming techniques.
引用
收藏
页码:253 / 258
页数:6
相关论文
共 50 条
  • [41] Active Fault-Tolerant Control Based on the Fault of Electromagnetic Hybrid Active Suspension
    Kou, Farong
    Wu, Jianghao
    Gao, Jian
    Wu, Dapeng
    Chen, Ruochen
    [J]. SHOCK AND VIBRATION, 2021, 2021
  • [42] Active Fault Tolerant Control of Networked Systems with Sensor Fault
    Pang, Zhonghua
    Zhang, Ji
    Zhou, Yuguo
    Han, Cunwu
    [J]. 2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 6468 - 6473
  • [43] Fault Estimation and Active Fault Tolerant Control for Servo Systems
    Guo, Fu M.
    Ren, Xue M.
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON REAL-TIME COMPUTING AND ROBOTICS (IEEE RCAR), 2016, : 644 - 649
  • [44] Fault detection and fault tolerant control of vehicle semi-active suspension system with magneto-rheological damper
    Du, Xiumei
    Han, Gaowei
    Yu, Miao
    Peng, Youxiang
    Xu, Xiaoying
    Fu, Jie
    [J]. SMART MATERIALS AND STRUCTURES, 2021, 30 (01)
  • [45] Sensor fault detection and active fault-tolerant control for the nonlinear mechatronic system based on optimized adaptive threshold
    Yu, Ming
    Li, Wanglin
    Lan, Dun
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (04): : 26 - 37
  • [46] Performance characteristics of Active Constrained Layer Damping versus Passive Constrained Layer Damping with Active Control
    Chen, T
    Baz, A
    [J]. MATHEMATICS AND CONTROL IN SMART STRUCTURES: SMART STRUCTURES AND MATERIALS 1996, 1996, 2715 : 256 - 268
  • [47] Sliding Modes for Fault Detection and Fault Tolerant Control
    Edwards, C.
    Alwi, H.
    Tan, C. P.
    da Silva, J. M. Andrade
    [J]. SLIDING MODES AFTER THE FIRST DECADE OF THE 21ST CENTURY: STATE OF THE ART, 2011, 412 : 293 - +
  • [48] A constrained Kohonen network and its application to sensor fault detection
    Chan, CW
    Cheung, KC
    Jin, H
    Zhang, HY
    [J]. AUTOMATIC CONTROL IN AEROSPACE 1998, 1999, : 249 - 254
  • [49] Active Fault Detection Based on a Statistical Test
    Sekunda, Andre
    Niemann, Henrik
    Poulsen, Niels Kjolstad
    [J]. 2016 3RD CONFERENCE ON CONTROL AND FAULT-TOLERANT SYSTEMS (SYSTOL), 2016, : 511 - 518
  • [50] Approximation Methods for Optimal Active Fault Detection
    Simandl, Miroslav
    Skach, Jan
    Puncochar, Ivo
    [J]. 2014 22ND MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2014, : 103 - 108