Radiation levels experienced by the insertion devices of the third-generation synchrotron radiation sources

被引:0
|
作者
Job, PK [1 ]
Alderman, J [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Third-generation synchrotron radiation sources like the Advanced Photon Source (APS) use insertion devices made of Nd-Fe-B permanent magnets to produce X-rays for scientific research. The concern of radiation-induced demagnetisation of these insertion devices spurred a-project aimed to measure and analyse the radiation levels experienced by these insertion devices during the operation of synchrotron radiation sources. The project required a reliable photon high-dose dosimetry technique capable of measuring high integrated dose levels during one operational cycle. Radiachromic dosimeters were considered for this purpose. In collaboration with the National Institute of Standards and Technology (NIST) these dosimeters were tested, calibrated and used at the Advanced Photon Source. Prior to each run radiachromic dosimeters are placed on the upstream and downstream edges of the 2.5 m long insertion devices. Following each operational cycle these dosimeters are retrieved from the storage ring and optical density changes are analysed. The measurements are compared with previous estimates. The results show that the previous predictions grossly underestimate the radiation levels received by the insertion devices.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [41] Macramolecular crystallography with a third-generation synchrotron source
    Lindley, PF
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1999, 55 : 1654 - 1662
  • [42] New synchrotron radiation sources and the next-generation light sources
    Hasnain, SS
    Kamitsubo, H
    Mills, DM
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 : 1171 - 1171
  • [43] Surface science done at third generation synchrotron radiation facilities
    Ferrer, S
    Petroff, Y
    [J]. SURFACE SCIENCE, 2002, 500 (1-3) : 605 - 627
  • [44] CONCEPTS FOR INSERTION DEVICES THAT WILL PRODUCE HIGH-QUALITY SYNCHROTRON RADIATION
    HALBACH, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 77 - 81
  • [45] X-ray beam/biomaterial thermal interactions in third-generation synchrotron sources
    Kuzay, TM
    Kazmierczak, M
    Hsieh, BJ
    [J]. ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 2001, 57 : 69 - 81
  • [46] X-ray diffraction measurement of liquid As2Se3 by using third-generation synchrotron radiation
    Kajihara, Y.
    Inui, M.
    Matsuda, K.
    Tamura, K.
    Hosokawa, S.
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 2007, 353 (18-21) : 1985 - 1989
  • [47] Conserving the coherence and uniformity of third-generation synchrotron radiation beams: the case of ID19, a 'long' beamline at the ESRF
    Espeso, JI
    Cloetens, P
    Baruchel, J
    Hartwig, J
    Mairs, T
    Biasci, JC
    Marot, G
    Salome-Pateyron, M
    Schlenker, M
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1243 - 1249
  • [48] UNDULATORS AS SOURCES OF SYNCHROTRON RADIATION
    KRINSKY, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (04) : 3078 - 3082
  • [49] PROPERTIES AND SOURCES OF SYNCHROTRON RADIATION
    BLUME, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 79 - PHYS
  • [50] Synchrotron radiation sources in Brazil
    Liu, L.
    Neuenschwander, R. T.
    Rodrigues, A. R. D.
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2019, 377 (2147):