Pulsatility imaging of saccular aneurysm model by 64-slice CT with dynamic multiscan technique

被引:13
|
作者
Yaghmai, Vahid
Rohany, Mehdi
Shaibani, Ali
Huber, Martin
Soud, Haytham
Russell, Eric J.
Walker, Matthew T.
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Siemens Med Solut, Malvern, PA USA
关键词
D O I
10.1016/j.jvir.2007.02.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of imaging pulsatility in an aneurysm model with the high-resolution dynamic multiscan technique of 64-slice computed tomography (CT) was studied. A pulsatile aneurysm phantom was constructed and imaged with dynamic multiscan technique. The aneurysm model was filled with iodinated contrast material (250 Hounsfield Units) and was scanned with use of a gantry rotation time of 0.33 seconds, slice thickness of 1.2 mm, effective coverage of 24 mm, and total imaging time of 4 seconds. Images were reconstructed at 50-msec intervals. The visualization of wall motion was qualitatively evaluated by direct comparison of four-dimensional images versus phantom motion. Pulsatility imaging without perceptible artifact or need for cardiac gating was achieved with the use of this technique.
引用
收藏
页码:785 / 788
页数:4
相关论文
共 50 条
  • [21] Radiation Dose to the Breast by 64-slice CT: Effects of Scanner Model and Study Protocol
    Qi, Zhihua
    Lemen, Lisa C.
    Lamba, Michael
    Chen, Hua-Hsuan
    Samaratunga, Ranasinghage
    Mahoney, Mary
    Hendrick, R. Edward
    ACADEMIC RADIOLOGY, 2016, 23 (08) : 987 - 993
  • [22] Diagnostic accuracy of 64-slice CT in the assessment of coronary stents
    Cademartiri, F.
    Palumbo, A.
    Maffei, E.
    La Grutta, L.
    Runza, G.
    Pugliese, F.
    Midiri, M.
    Mollet, N. R. A.
    Meijboom, W. B.
    Menozzi, A.
    Vignali, L.
    Reverberi, C.
    Ardissino, D.
    Krestin, G. P.
    RADIOLOGIA MEDICA, 2007, 112 (04): : 526 - 537
  • [23] 64-Slice CT urography: 30 months of clinical experience
    Martingano, P.
    Stacul, F.
    Cavallaro, M.
    Casagrande, F.
    Cernic, S.
    Belgrano, M.
    Cova, M.
    RADIOLOGIA MEDICA, 2010, 115 (06): : 920 - 935
  • [24] Evaluation of Normal Adrenal Gland Volume by 64-slice CT
    Xuan Wang
    Zheng-yu Jin
    Hua-dan Xue
    Wei Liu
    Hao Sun
    Yu Chen
    Kai Xu
    ChineseMedicalSciencesJournal, 2012, 27 (04) : 220 - 224
  • [25] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [26] Myocardial infarction imaging by early and late-phase 64-slice CT in comparison to MRI
    Nieman, Koen
    Shapiro, Michael
    Ferencik, Maros
    Nomura, Cesar
    Abbara, Suhny
    Hoffmann, Udo
    Jang, Ik-Kyung
    Brady, Thomas
    Cury, Ricardo
    CIRCULATION, 2006, 114 (18) : 384 - 385
  • [27] Caseous calcification of the mitral annulus imaged with 64-slice multidetector CT and magnetic resonance imaging
    Vanovermeire, Olivier M.
    Duerinckx, Andre J.
    Duncan, David A.
    Russell, Wilson G.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2006, 22 (3-4): : 553 - 559
  • [28] Evaluation of the Optimal Image Reconstruction Interval for Coronary Artery Imaging Using 64-slice CT
    Weininger, M.
    Ritter, C.
    Beer, M.
    Hahn, D.
    Beissert, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [29] Evaluation of circle of Willis variations with 64-slice CT angiography
    Li, Qi
    Xie, Peng
    Lv, Fajin
    Luo, Tianyou
    NEUROLOGY, 2008, 70 (11) : A158 - A158
  • [30] Characterization of mandibular fractures using 64-slice multidetector CT
    Ogura, I.
    Kaneda, T.
    Mori, S.
    Sekiya, K.
    Ogawa, H.
    Tsukioka, T.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) : 392 - 395