Pulsatility imaging of saccular aneurysm model by 64-slice CT with dynamic multiscan technique

被引:13
|
作者
Yaghmai, Vahid
Rohany, Mehdi
Shaibani, Ali
Huber, Martin
Soud, Haytham
Russell, Eric J.
Walker, Matthew T.
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Siemens Med Solut, Malvern, PA USA
关键词
D O I
10.1016/j.jvir.2007.02.037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The feasibility of imaging pulsatility in an aneurysm model with the high-resolution dynamic multiscan technique of 64-slice computed tomography (CT) was studied. A pulsatile aneurysm phantom was constructed and imaged with dynamic multiscan technique. The aneurysm model was filled with iodinated contrast material (250 Hounsfield Units) and was scanned with use of a gantry rotation time of 0.33 seconds, slice thickness of 1.2 mm, effective coverage of 24 mm, and total imaging time of 4 seconds. Images were reconstructed at 50-msec intervals. The visualization of wall motion was qualitatively evaluated by direct comparison of four-dimensional images versus phantom motion. Pulsatility imaging without perceptible artifact or need for cardiac gating was achieved with the use of this technique.
引用
收藏
页码:785 / 788
页数:4
相关论文
共 50 条
  • [11] 64-slice CT: a comparison with invasive coronary angiography
    Ruth Kirby
    Nature Clinical Practice Cardiovascular Medicine, 2005, 2 (11): : 552 - 552
  • [12] Coronary sinus in 64-slice CT - preliminary study
    Drzewiecka, A.
    Mlynarski, R.
    Kargul, W.
    Gasior, Z.
    EUROPEAN HEART JOURNAL, 2006, 27 : 144 - 145
  • [13] Clinical application and technique of 64-slice spiral CT subtraction angiography in head and neck
    Yang, Lie
    Huang, Xien
    Duan, Shaoyin
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2012, 41 (01) : 27 - 33
  • [14] Evaluation of dose exposure in 64-slice CT colonography
    Luz, O.
    Buchgeister, M.
    Klabunde, M.
    Trabold, T.
    Kopp, A. F.
    Claussen, C. D.
    Heuschmid, M.
    EUROPEAN RADIOLOGY, 2007, 17 (10) : 2616 - 2621
  • [15] 64-Slice CT urography: optimisation of radiation dose
    Martingano, P.
    Stacul, F.
    Cavallaro, M. F.
    Cernic, S.
    Bregant, P.
    Cova, M. A.
    RADIOLOGIA MEDICA, 2011, 116 (03): : 417 - 431
  • [16] Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT
    Lotus Desbiolles
    Sebastian Leschka
    André Plass
    Hans Scheffel
    Lars Husmann
    Oliver Gaemperli
    Elisabeth Garzoli
    Borut Marincek
    Philipp A. Kaufmann
    Hatem Alkadhi
    European Radiology, 2007, 17 (11) : 2819 - 2828
  • [17] Introduction to coronary imaging with 64-slice computed tomography
    Cademartiri, F
    Runza, G
    Belgrano, M
    Luccichenti, G
    Mollet, NR
    Malagutti, P
    Silvestrini, M
    Midiri, M
    Cova, M
    Mucelli, RP
    Krestin, GP
    RADIOLOGIA MEDICA, 2005, 110 (1-2): : 16 - 41
  • [18] Surgery of saphenous vein graft aneurysm based on 64-slice computed tomography (CT) diagnostic assessment
    Mandegar, Mohammad Hossein
    Roshanali, Farideh
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 31 (06) : 1137 - 1137
  • [19] Usefulness of 64-Slice Computed Tomography for Evaluation of Atrial Septal Aneurysm
    Zeina, Abdel Rauf
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2011, 13 (10): : 645 - 646
  • [20] Feasibility of extended-coverage perfusion and dynamic computer tomography (CT) angiography using toggling-table technique on 64-slice CT
    Horiguchi, Jun
    Kiura, Yoshihiro
    Tanaka, Junpei
    Fukuda, Hiroshi
    Kiguchi, Masao
    Fujioka, Chikako
    Kurisu, Kaoru
    Awai, Kazuo
    JOURNAL OF NEURORADIOLOGY, 2011, 38 (03) : 156 - 160