A cine-EPID based method for jaw detection and quality assurance for tracking jaw in IMRT/VMAT treatments

被引:15
|
作者
Fuangrod, Todsaporn [1 ]
Rowshanfarzad, Pejman [2 ]
Greer, Peter B. [3 ,4 ]
Middleton, Richard H. [1 ]
机构
[1] Univ Newcastle, Fac Engn & Built Environm, Sch Elect Engn & Comp Sci, Callaghan, NSW 2308, Australia
[2] Univ Western Australia, Sch Phys, Crawley, WA 6009, Australia
[3] Univ Newcastle, Fac Sci & IT, Sch Math & Phys Sci, Callaghan, NSW 2308, Australia
[4] Calvary Mater Newcastle Hosp, Dept Radiat Oncol, Newcastle, NSW 2310, Australia
来源
关键词
Real-time verification; Jaws; QA; EPID; RADIOCHROMIC FILM; DOSIMETRY;
D O I
10.1016/j.ejmp.2014.11.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new tool with the potential to verify and track jaw position during delivery has been developed. The method should be suitable for independent quality assurance for jaw position during jaw tracking dynamic IMRT and VMAT treatments. The jaw detection and tracking algorithm developed consists of five main steps. Firstly, the image is enhanced by removing a normalised predicted EPID image (that does not include the collimator transmission) from each cine EPID image. Then, using a histogram clustering technique a global intensity threshold level was determined. This threshold level was used to classify each pixel of the image as either under the jaws or under the MLC. Additionally, the collimator angle was automatically detected and used to rotate the image to vertical direction. Finally, this rotation allows the jaw positions to be determined using vertical and horizontal projection profiles. Nine IMRT fields (with static jaws) and a single VMAT clinical field (with dynamic jaws) were tested by determining the root mean square difference between planned and detected jaw positions. The test results give a detection accuracy of +/-1 mm RMS error for static jaw IMRT treatments and +/-1.5 mm RMS error for the dynamic jaw VMAT treatment. This method is designed for quality assurance and verification in modern radiation therapy; to detect the position of static jaws or verify the position of tracking jaws in more complex treatments. This method uses only information extracted from EPID images and it is therefore independent from the linear accelerator. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 36
页数:21
相关论文
共 35 条
  • [1] A New Method for Linear Accelerator Characterization for VMAT Using Cine-EPID
    Rowshanfarzad, P.
    Sabet, M.
    McCowan, P.
    McCurdy, B.
    O'Connor, D.
    Greer, P. B.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3726 - +
  • [2] An EPID based method for efficient and precise asymmetric jaw alignment quality assurance
    Clews, Luke
    Greer, Peter B.
    [J]. MEDICAL PHYSICS, 2009, 36 (12) : 5488 - 5496
  • [3] DEVELOPMENT OF AN A-SI EPID-BASED SYSTEM FOR MACHINE, IMRT AND VMAT QUALITY ASSURANCE
    Vazquez-Quino, L. A.
    Chen, X.
    Fitzpatrick, M.
    Shi, C.
    Mavroidis, P.
    Alkhatib, H.
    Mihailidis, D.
    Papanikolaou, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S170 - S171
  • [4] A fast jaw-tracking model for VMAT and IMRT Monte Carlo simulations
    Townson, Reid
    Egglestone, Hilary
    Zavgorodni, Sergei
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 26 - 34
  • [5] MU-EPID An EPID Based Tool for IMRT Quality Assurance
    Quino, L. Vazquez
    Stathakis, S.
    Gutierrez, A.
    Esquivel, C.
    Alkhatib, H.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3967 - 3967
  • [6] Dosimetric Influence of Jaw Tracking Option On Lung SBRT Using VMAT and IMRT Techniques
    Amoush, A.
    Ferjani, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3108 - 3108
  • [7] A VMAT Quality Assurance Technique Based on EPID in Cine Mode for Large Field Gynecological Cancer Radiation Therapy
    Wu, Q.
    Craciusnescu, O.
    Liang, B.
    Light, K.
    Vergalasova, I.
    Liu, B.
    Zhou, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E682 - E682
  • [8] A new video optic based EPID system for IMRT treatment quality assurance
    Yang, C
    Chen, H
    Murphy, S
    Celi, JC
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1367 - 1367
  • [9] A new video optic based EPID system for IMRT treatment quality assurance
    Yang, CJ
    Chen, H
    Celi, JC
    [J]. RADIOLOGY, 2002, 225 : 178 - 178
  • [10] An EPID-based system for gantry-resolved MLC quality assurance for VMAT
    Zwan, Benjamin J.
    Barnes, Michael P.
    Fuangrod, Todsaporn
    Stanton, Cameron J.
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 348 - 365