A VMAT Quality Assurance Technique Based on EPID in Cine Mode for Large Field Gynecological Cancer Radiation Therapy

被引:0
|
作者
Wu, Q. [1 ]
Craciusnescu, O. [1 ]
Liang, B. [2 ]
Light, K. [3 ]
Vergalasova, I. [3 ]
Liu, B. [2 ]
Zhou, F. [2 ]
机构
[1] Duke Univ, Durham, NC USA
[2] Beihang Univ, Beijing, Peoples R China
[3] Duke Univ, Med Ctr, Durham, NC USA
关键词
D O I
10.1016/j.ijrobp.2016.06.2334
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
3670
引用
收藏
页码:E682 / E682
页数:1
相关论文
共 50 条
  • [1] A Novel Technique for VMAT QA with EPID in Cine Mode On Varian TrueBeam
    Liu, B.
    Adamson, J.
    Rodrigues, A.
    Zhou, F.
    Yin, F.
    Wu, Q.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] A novel technique for VMAT QA with EPID in cine mode on a Varian TrueBeam linac
    Liu, Bo
    Adamson, Justus
    Rodrigues, Anna
    Zhou, Fugen
    Yin, Fang-fang
    Wu, Qiuwen
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6683 - 6700
  • [3] A cine-EPID based method for jaw detection and quality assurance for tracking jaw in IMRT/VMAT treatments
    Fuangrod, Todsaporn
    Rowshanfarzad, Pejman
    Greer, Peter B.
    Middleton, Richard H.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (01): : 16 - 36
  • [4] Epid cine acquisition mode for in vivo dosimetry in dynamic are radiation therapy
    Fidanzio, Andrea
    Mameli, Alessandra
    Placidi, Elisa
    Greco, Francesca
    Stimato, Gerardina
    Gaudino, Diego
    Rarnella, Sara
    D'Angelillo, Rolando
    Cellini, Francesco
    Trodella, Lucio
    Cilla, Savino
    Grimaldi, Luca
    D'Onofrio, Guido
    Azario, Luigi
    Piermattei, Angelo
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (04): : 658 - 666
  • [5] An EPID-based system for gantry-resolved MLC quality assurance for VMAT
    Zwan, Benjamin J.
    Barnes, Michael P.
    Fuangrod, Todsaporn
    Stanton, Cameron J.
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 348 - 365
  • [6] Implementation of EPID based quality assurance procedures for radiation and optical fields
    Smale, J
    Norrlinger, B
    Van Prooijen, M
    Rink, A
    Heaton, R
    Islam, M
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1996 - 1996
  • [7] DEVELOPMENT OF AN A-SI EPID-BASED SYSTEM FOR MACHINE, IMRT AND VMAT QUALITY ASSURANCE
    Vazquez-Quino, L. A.
    Chen, X.
    Fitzpatrick, M.
    Shi, C.
    Mavroidis, P.
    Alkhatib, H.
    Mihailidis, D.
    Papanikolaou, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S170 - S171
  • [8] EPID-BASED QUALITY ASSURANCE FOR VOLUMETRIC MODULATED ARC THERAPY
    Hoffmann, L.
    Jorgensen, M. B. Kyed
    Petersen, J.
    Praestegaard, L. H.
    Hansen, R.
    Muren, L. P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S82 - S83
  • [9] Physical dosimetry of volumetric modulated arc therapy (VMAT) using EPID and 2D array for quality assurance
    Mohamed, Ismail E.
    Ibrahim, Ayman G.
    Zidan, Hamdy M.
    El-Bahkiry, Hesham S.
    El-sahragti, Adel Y.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (02): : 477 - 484
  • [10] Statistical analysis of EPID-based VMAT patient-specific quality assurance and investigation of contributing factors
    Szwec, Stuart
    Greer, Peter
    Lee, Danny
    Barnes, Michael
    Hernandez, Victor
    Saez, Jordi
    Lam, Dao
    Sun, Baozhou
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2020, 16 : 39 - 39