Quality assurance of stereotactic treatment planning system: implementation of Monte Carlo technique on Leksell Gamma Knife

被引:0
|
作者
Cheung, YC [1 ]
Yu, KN [1 ]
Yu, CP [1 ]
Ho, TK [1 ]
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
来源
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
The purpose of this report is to describe the quality assurance (QA) program on the treatment planning system, Leksell GammaPlan, using the Monte Carlo (MC) technique. Routine dose distribution measurements using a spherical polystyrene phantom and GafChromic films may not give accurate results since the measurements are not performed in a water medium and the small energy dependence of GafChromic films may affect the measurement results. Comparison of the dose distributions solely from measurement results and the GammaPlan output is not sufficient, hn alternative QA program on GammaPlan using the MC technique is introduced. The results from GammaPlan showed good consistency with the MC results. Small discrepancies of the relative dose along the z axis were observed on the 8 mm collimator helmet. Such discrepancies may however be too small to give clinical significance.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 50 条
  • [1] CT based Monte Carlo (PENELOPE) treatment plan verification system for Leksell Gamma Knife stereotactic radiosurgery
    Moskvin, V
    Papiez, L
    Desrosiers, C
    Timmerman, R
    Hoopes, D
    Randall, M
    DesRosiers, P
    MEDICAL PHYSICS, 2004, 31 (06) : 1876 - 1876
  • [2] Development of a Monte Carlo model for treatment planning dose verification of the Leksell Gamma Knife Perfexion radiosurgery system
    Yuan, Jiankui
    Lo, Simon S.
    Zheng, Yiran
    Sohn, Jason W.
    Sloan, Andrew E.
    Ellis, Rodney
    Machtay, Mitchell
    Wessels, Barry
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 190 - 201
  • [3] Quality Assurance for the Leksell Gamma Knife Perfexion™
    Petti, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Inhomogeneity Correction using Monte Carlo Simulation for Leksell Gamma Knife Stereotactic Radiosurgery
    Moskvin, V. P.
    Henderson, M. A.
    Barriger, B.
    Can, M.
    DesRosiers, C.
    Johnstone, P. A. S.
    Das, I. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S680 - S680
  • [5] Fractionated stereotactic radiotherapy with the Leksell Gamma Knife - Target dose calculation and quality assurance
    Novotny, J
    Novotny, J
    Simonova, G
    Liscak, R
    Vladyka, V
    RADIOSURGERY 1997, 1998, 2 : 197 - 205
  • [6] Practical quality assurance of the automatic positioning system on the Leksell Gamma Knife
    Lerma, F
    Drzymala, RE
    MEDICAL PHYSICS, 2003, 30 (06) : 1363 - 1363
  • [7] The commissioning and quality assurance of the Automatic Positioning System on the Leksell gamma knife
    Soanes, T
    Hampshire, A
    Vaughan, P
    Brownett, C
    Rowe, J
    Radatz, M
    Kemeny, A
    Walton, L
    JOURNAL OF NEUROSURGERY, 2002, 97 : 574 - 578
  • [8] Filmless quality assurance of a Leksell Gamma Knife® Icon™
    Maraghechi, Borna
    Kim, Taeho
    Mitchell, Timothy J.
    Goddu, S. Murty
    Dise, Joe
    Kavanaugh, James A.
    Zoberi, Jacqueline E.
    Mutic, Sasa
    Knutson, Nels C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 59 - 67
  • [9] Implementation of Monte Carlo simulations for the Gamma Knife system
    Xiong, W.
    Huang, D.
    Lee, L.
    Feng, J.
    Morris, K.
    Calugaru, E.
    Burman, C.
    Li, J.
    Ma, C-M
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [10] Stereotactic treatment of meningiomas using Leksell gamma knife
    Liscak, R
    Vladyka, V
    Simonova, G
    Subrt, O
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 1996, 59 (02): : 73 - 79