Corneal endothelial damage in phacoemulsification using an anterior chamber maintainer compared with using an ophthalmic viscosurgical device

被引:3
|
作者
Mayali, Huseyin [1 ]
Baser, Esin Fatma [2 ]
Kurt, Emin [1 ]
Ilker, Suleyman Sami [1 ]
机构
[1] Manisa Celal Bayar Univ, Dept Ophthalmol, Manisa, Turkey
[2] Karsiyaka Eye Hosp, Dept Ophthalmol, Izmir, Turkey
来源
关键词
INTRAOCULAR-LENS IMPLANTATION; VISCOELASTIC SUBSTANCES; CATARACT-SURGERY; CELL LOSS; HEALON5; PROTECTION; THICKNESS; PRESSURE; DENSITY;
D O I
10.1097/j.jcrs.0000000000000493
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effects of phacoemulsification surgery (PE) using an anterior chamber maintainer (ACM) and conventional PE using an ophthalmic viscosurgical device (OVD) on corneal endothelial cells. Setting: Department of Ophthalmology, Celal Bayar University, Manisa, Turkey. Design: Prospective randomized controlled trial. Methods: Eyes in the OVD group (n = 50) underwent conventional PE, whereas eyes in the ACM group (n = 50) underwent PE using an ACM. Endothelial cell density (ECD), coefficient of variation (CV), hexagonality (HEX), and noncontact central corneal thickness (CCT) measurements were performed by specular microscopy before and at 1 month, 3 months, and 6 months after PE. Results: This study included 100 eyes of 97 patients undergoing PE. The mean age was 64.7 ? 10.6 years in the OVD group, 64.0 ? 12.6 years in the ACM group (P > .05). The groups did not differ significantly in preoperative ECD, CV, HEX, and CCT or total PE time (P > .05 for all). ECD was significantly lower in the ACM group compared with the OVD group at postoperative 1 month, 3 months, and 6 months (P = .002, P = .002, and P = .001, respectively). Similarly, ECD loss compared with preoperative value was greater in the ACM group at all postoperative timepoints (P = .003, P = .001, and P = .001, respectively). CV increased and HEX decreased in both groups postoperatively (P > .05 for both). CCT showed a transient increase of less than 10 mm at postoperative 1 month in both groups (P = .296). Conclusions: PE with ACM was associated with greater corneal ECD loss compared with conventional PE. ACM should not be used during PE in patients with limited corneal endothelial reserve. J Cataract Refract Surg 2021; 47:612?617 Copyright ? 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [41] CORNEAL ENDOTHELIAL-CELL LOSS FOLLOWING PHACOEMULSIFICATION USING THE SMALL-PORT PHACO
    HAYASHI, K
    NAKAO, F
    HAYASHI, F
    OPHTHALMIC SURGERY AND LASERS, 1994, 25 (08): : 510 - 513
  • [42] Comparison of effective phacoemulsification time and corneal endothelial cell loss using 2 ultrasound frequencies
    Dewan, Taru
    Malik, Praveen Kumar
    Kumari, Ritu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09): : 1285 - 1293
  • [43] Determining factors for corneal endothelial cell loss by using bimanual microincision phacoemulsification and power modulation
    Mathys, Kenneth C.
    Cohen, Kenneth L.
    Armstrong, Brian D.
    CORNEA, 2007, 26 (09) : 1049 - 1055
  • [44] TRANSPLANTATION OF CORNEAL ENDOTHELIAL-CELLS USING A CELL CARRIER DEVICE
    MOHAY, J
    LANGE, TM
    SOLTAU, JB
    WOOD, TO
    MCLAUGHLIN, BJ
    CORNEA, 1994, 13 (02) : 173 - 182
  • [45] Evaluation of phacoemulsification-induced oxidative stress and damage of cultured human corneal endothelial cells in different solutions using redox fluorometry microscopy
    Nishi, Yutaro
    Engler, Christoph
    Na, Dae Ro
    Kashiwabuchi, Renata T.
    Shin, Young Joo
    Cano, Marisol
    Jun, Albert S.
    Chuck, Roy S.
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e323 - e327
  • [46] Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different Devices
    Shajari, Mehdi
    Lehmann, Ulrike C.
    Kohnen, Thomas
    CORNEA, 2016, 35 (06) : 838 - 842
  • [47] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576
  • [48] A Novel Marking Technique for Descemet Membrane Endothelial Graft Using an Ophthalmic Viscoelastic Device
    Or, Lior
    Krakauer, Yonit
    Sorkin, Nir
    Knyazer, Boris
    Ashkenazy, Zach
    Gushansky, Kostya
    Dubinsky-Pertzov, Biana
    Gazit, Inbal
    Einan-Lifshitz, Adi
    CORNEA, 2021, 40 (04) : 529 - 532
  • [49] Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system
    Kocak, Ibrahim
    Kocak, Funda
    Teker, Bahri
    Aydin, Ali
    Kaya, Faruk
    Baybora, Hakan
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (04) : 686 - 688
  • [50] Evaluation of bacterial contamination rate of the anterior chamber during phacoemulsification surgery using an automated microbial detection system
    Ibrahim Kocak
    Funda Kocak
    Bahri Teker
    Ali Aydin
    Faruk Kaya
    Hakan Baybora
    International Journal of Ophthalmology, 2014, (04) : 686 - 688