Corneal endothelial damage in phacoemulsification using an anterior chamber maintainer compared with using an ophthalmic viscosurgical device

被引:3
|
作者
Mayali, Huseyin [1 ]
Baser, Esin Fatma [2 ]
Kurt, Emin [1 ]
Ilker, Suleyman Sami [1 ]
机构
[1] Manisa Celal Bayar Univ, Dept Ophthalmol, Manisa, Turkey
[2] Karsiyaka Eye Hosp, Dept Ophthalmol, Izmir, Turkey
来源
关键词
INTRAOCULAR-LENS IMPLANTATION; VISCOELASTIC SUBSTANCES; CATARACT-SURGERY; CELL LOSS; HEALON5; PROTECTION; THICKNESS; PRESSURE; DENSITY;
D O I
10.1097/j.jcrs.0000000000000493
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the effects of phacoemulsification surgery (PE) using an anterior chamber maintainer (ACM) and conventional PE using an ophthalmic viscosurgical device (OVD) on corneal endothelial cells. Setting: Department of Ophthalmology, Celal Bayar University, Manisa, Turkey. Design: Prospective randomized controlled trial. Methods: Eyes in the OVD group (n = 50) underwent conventional PE, whereas eyes in the ACM group (n = 50) underwent PE using an ACM. Endothelial cell density (ECD), coefficient of variation (CV), hexagonality (HEX), and noncontact central corneal thickness (CCT) measurements were performed by specular microscopy before and at 1 month, 3 months, and 6 months after PE. Results: This study included 100 eyes of 97 patients undergoing PE. The mean age was 64.7 ? 10.6 years in the OVD group, 64.0 ? 12.6 years in the ACM group (P > .05). The groups did not differ significantly in preoperative ECD, CV, HEX, and CCT or total PE time (P > .05 for all). ECD was significantly lower in the ACM group compared with the OVD group at postoperative 1 month, 3 months, and 6 months (P = .002, P = .002, and P = .001, respectively). Similarly, ECD loss compared with preoperative value was greater in the ACM group at all postoperative timepoints (P = .003, P = .001, and P = .001, respectively). CV increased and HEX decreased in both groups postoperatively (P > .05 for both). CCT showed a transient increase of less than 10 mm at postoperative 1 month in both groups (P = .296). Conclusions: PE with ACM was associated with greater corneal ECD loss compared with conventional PE. ACM should not be used during PE in patients with limited corneal endothelial reserve. J Cataract Refract Surg 2021; 47:612?617 Copyright ? 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [1] Comparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial
    Nayak, B. K.
    Jain, Elesh Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2009, 57 (02) : 99 - 103
  • [2] Corneal endothelial cell coating during phacoemulsification using a new dispersive hyaluronic acid ophthalmic viscosurgical device
    Kretz, Florian T. A.
    Limberger, I-Joo
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1879 - 1884
  • [3] Effect of continuous ultrasonic phacoemulsification with anterior chamber maintainer on corneal endothelial damage in hard nuclear cataract
    Chen, Guangsheng
    Wang, Dongmei
    Du, Yi
    Huang, Hongbo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (03) : 198 - 201
  • [4] Corneal endothelial cell loss and intraocular pressure following phacoemulsification using a new viscous-cohesive ophthalmic viscosurgical device
    Wood, Keren
    Pessach, Yuval
    Kovalyuk, Natalya
    Lifshitz, Michal
    Winter, Halit
    Pikkel, Joseph
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [5] Advances in Understanding the Mechanism of Ophthalmic Viscosurgical Device Retention in the Anterior Chamber or on the Corneal Surface during Ocular Surgery
    Watanabe, Ippei
    Yoshioka, Keiji
    Takahashi, Katsuya
    Hoshi, Hirotaka
    Nagata, Mayumi
    Matsushima, Hiroyuki
    Suzuki, Kiyoshi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2021, 69 (06) : 595 - 599
  • [6] Effects of Combinations of Ophthalmic Viscosurgical Devices and Suction Flow Rates on the Corneal Endothelial Cell Damage Incurred during Phacoemulsification
    Kunishige, Tomoyuki
    Takahashi, Hiroshi
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [7] Comparison of Corneal Endothelial Cell Changes after Phacoemulsification using Different Viscosurgical Devices
    Zhang, Hongyan
    Li, Mozhu
    Song, Xudong
    Song, Hongxin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] USING AN ANTERIOR-CHAMBER MAINTAINER TO CONTROL INTRAOCULAR-PRESSURE DURING PHACOEMULSIFICATION
    BLUMENTHAL, M
    ASSIA, EI
    CHEN, V
    AVNI, I
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 93 - 96
  • [9] Fluid Temperature at the Corneal Endothelium during Phacoemulsification: Comparison of an Ophthalmic Viscosurgical Device and Balanced Salt Solution Using the Finite Element Method
    Reepolmaha, Somporn
    Limtrakarn, Wiroj
    Uthaisang-Tanechpongtamb, Wanlaya
    Dechaumphai, Pramote
    OPHTHALMIC RESEARCH, 2010, 43 (04) : 173 - 178
  • [10] Protective effect of different ophthalmic viscosurgical devices on corneal endothelial cells during phacoemulsification: Rabbit model
    Ben-Eliahu, Shmuel
    Tal, Kfir
    Milstein, Asher
    Levin-Harrus, Tal
    Ezov, Nati
    Kleinmann, Guy
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (11): : 1972 - 1975