Response of a lithium gadolinium borate scintillator in monoenergetic neutron fields

被引:13
|
作者
Williams, AM [1 ]
Beeley, PA
Spyrou, NM
机构
[1] HMS Sultan, Nucl Dept, Gosport PO12 3BY, Hants, England
[2] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
关键词
D O I
10.1093/rpd/nch382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate estimation of neutron dose requires knowledge of the neutron energy distribution in the working environment. Existing neutron spectrometry systems, Bonner spheres for example, are large and bulky, and require long data acquisition times. A portable system that could indicate the approximate neutron energy spectrum in a short time would be extremely useful in radiation protection. A composite scintillator, consisting of lithium gadolinium borate crystals in a plastic scintillator matrix, produced by Photogenics is being tested for this purpose. A prototype device based on this scintillator and digital pulse processing electronics has been calibrated using quasi-monoenergetic neutron fields at the low-scatter facility of the UK National Physical Laboratory (NPL). Energies selected were 144, 250, 565, 1400, 2500 and 5000 keV, with correction for scattered neutrons being made using the shadow cone technique. Measurements were also made in the NPL thermal neutron field. Pulse distributions collected with the digitiser in capture-gated mode are presented, and detection efficiency and energy resolution derived. For comparison, neutron spectra were also collected using the commercially available Microspec N-Probe from Bubble Technology Industries, which consists of an NE213 scintillator and a He-3 proportional counter.
引用
收藏
页码:497 / 502
页数:6
相关论文
共 50 条
  • [21] Photon spectra in NPL standard monoenergetic neutron fields
    Roberts, N. J.
    Bennett, A.
    Cheema, S. S.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1685 - 1688
  • [22] Analysis of the response of innovative neutron detectors with monoenergetic neutron beams
    Romei, C.
    Ciolini, R.
    Di Fulvio, A.
    Mirzajani, N.
    Selici, S.
    Souza, S. O.
    Piotto, M.
    Esposito, J.
    Colautti, P.
    d'Errico, F.
    MULTIDISCIPLINARY APPLICATIONS OF NUCLEAR PHYSICS WITH ION BEAMS (ION BEAMS '12), 2013, 1530 : 82 - 86
  • [23] A HIGH EFFICIENCY, GADOLINIUM LOADED MINERAL OIL SCINTILLATOR FOR NEUTRON DETECTION
    CLARK, GE
    MORRISON, RC
    OLAUGHLI.JW
    BURKHOLDER, HR
    NUCLEAR INSTRUMENTS & METHODS, 1970, 84 (01): : 67 - +
  • [24] Lithium indium diselenide: A new scintillator for neutron imaging
    Lukosi, Eric
    Herrera, Elan
    Hamm, Daniel
    Lee, Kyung-Min
    Wiggins, Brenden
    Trtik, Pavel
    Penumadu, Dayakar
    Young, Stephen
    Santodonato, Louis
    Bilheux, Hassina
    Burger, Arnold
    Matei, Liviu
    Stowe, Ashley C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 : 140 - 149
  • [25] Lithium Aluminate Crystals as Scintillator for Thermal Neutron Detection
    Fujimoto, Yutaka
    Kamada, Kei
    Yanagida, Takayuki
    Kawaguchi, Noriaki
    Kurosawa, Shunsuke
    Totsuka, Daisuke
    Fukuda, Kentaro
    Watanabe, Kenichi
    Yamazaki, Atsushi
    Yokota, Yuui
    Yoshikawa, Akira
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2252 - 2255
  • [26] USING A LITHIUM GLASS SCINTILLATOR TO RECORD NEUTRON RADIATION
    Fedorov, S. G.
    MEASUREMENT TECHNIQUES, 2019, 61 (12) : 1234 - 1237
  • [27] Using a Lithium Glass Scintillator to Record Neutron Radiation
    S. G. Fedorov
    Measurement Techniques, 2019, 61 : 1234 - 1237
  • [28] Experimental characterization of the LUPIN Rem counter in monoenergetic neutron fields
    Cirillo, Andrea
    Caresana, Marco
    EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (08):
  • [29] Characterization of bonner sphere systems at monoenergetic and thermal neutron fields
    Lacoste, V
    Gressier, V
    Pochat, JL
    Fernández, F
    Bakali, M
    Bouassoule, T
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 529 - 532
  • [30] Characterization of Monoenergetic Low Energy Neutron Fields with the μTPC Detector
    Golabek, C.
    Billard, J.
    Grignon, C.
    Bosson, G.
    Bourrion, O.
    Guillaudin, O.
    Lebreton, L.
    Mayet, F.
    Petit, M.
    Richer, J-P
    Santos, D.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412