Using a Lithium Glass Scintillator to Record Neutron Radiation

被引:0
|
作者
S. G. Fedorov
机构
[1] All-Russia Research Institute of Physicotechnical and Radio Measurements (VNIIFTRI),
[2] National Research Nuclear University MEPhI (Moscow Engineering Physics Institute),undefined
来源
Measurement Techniques | 2019年 / 61卷
关键词
neutron radiation sources; gamma radiation sources; scintillation detectors; lithium glass; spherical moderators; thermal neutrons;
D O I
暂无
中图分类号
学科分类号
摘要
Studies have been performed to improve the accuracy of energy measurements of neutron fields and to improve the spectrometric analysis of neutron radiation fields using scintillation detectors. The use of a scintillation detector based on 6Li2O lithium glasses of various diameters and thicknesses for recording neutron radiation energy, 0.4–15·106 eV, is considered. The main characteristics of this scintillation detector and the results of measurements obtained with it are compared with the characteristics and results of measurements of the scintillator using LiI (Eu). Spherical moderators with diameters of 70–300 mm were used for scintillation detector operation.
引用
收藏
页码:1234 / 1237
页数:3
相关论文
共 50 条
  • [1] USING A LITHIUM GLASS SCINTILLATOR TO RECORD NEUTRON RADIATION
    Fedorov, S. G.
    MEASUREMENT TECHNIQUES, 2019, 61 (12) : 1234 - 1237
  • [2] GLASS SCINTILLATOR FOR NEUTRON DETECTION
    BISHAY, AM
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1961, 44 (05) : 231 - 233
  • [3] A Monte Carlo Model of the Neutron Detector Based on Lithium-Glass Scintillator
    Kuzmin, E. S.
    Bokuchava, G. D.
    Zimin, I. Yu
    Kruglov, A. A.
    Kuchinskiy, N. A.
    Malyshev, V. L.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2021, 64 (02) : 195 - 201
  • [4] A Monte Carlo Model of the Neutron Detector Based on Lithium-Glass Scintillator
    E. S. Kuzmin
    G. D. Bokuchava
    I. Yu. Zimin
    A. A. Kruglov
    N. A. Kuchinskiy
    V. L. Malyshev
    Instruments and Experimental Techniques, 2021, 64 : 195 - 201
  • [5] Low-energy neutron flux measurement using a resonance absorption filter surrounding a lithium glass scintillator
    Ghal-Eh, N.
    Koohi-Fayegh, R.
    Hamidi, S.
    RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (06) : 917 - 920
  • [6] Thermal neutron detection with the lithium borate scintillator
    Forschungszentrum Juelich GmbH, Juelich, Germany
    IEEE Transactions on Nuclear Science, 2000, 47 (3 II) : 948 - 951
  • [7] Thermal neutron detection with the lithium berate scintillator
    Engels, R
    Reinartz, R
    Schelten, J
    Czirr, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 948 - 951
  • [8] Thermal neutron detection with the lithium berate scintillator
    Engels, R
    Reinartz, R
    Schelten, J
    Czirr, B
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 682 - 685
  • [9] Lithium Glass Scintillator Neutron Detector as an Improved Alternative to the Standard 3He Proportional Counter
    Popov, Vladimir
    Degtiarenko, Pavel
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1819 - 1822
  • [10] Lithium indium diselenide: A new scintillator for neutron imaging
    Lukosi, Eric
    Herrera, Elan
    Hamm, Daniel
    Lee, Kyung-Min
    Wiggins, Brenden
    Trtik, Pavel
    Penumadu, Dayakar
    Young, Stephen
    Santodonato, Louis
    Bilheux, Hassina
    Burger, Arnold
    Matei, Liviu
    Stowe, Ashley C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 830 : 140 - 149