Management of comminuted patellar fracture with non-absorbable suture cerclage and Nitinol patellar concentrator

被引:16
|
作者
Lue, Tan Hong [1 ]
Feng, Liu Wei [2 ]
Jun, Wang Ming [1 ]
Yin, Li Wu [1 ]
机构
[1] Luoyang Orthoped Traumatol Hosp, Dept Orthoped Surg, Luoyang 471002, Peoples R China
[2] Jiangsu Univ, Changzhou Wujin Hosp, Dept Orthoped Surg, Changzhou 213002, Peoples R China
关键词
Patellar fracture; Comminuted fracture; Non-absorbable suture cerclage; Nitinol patellar concentrator; BRAIDED POLYESTER SUTURE; FIXATION;
D O I
10.1016/j.injury.2014.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To evaluate the effectiveness and safety of a fixation technique for comminuted patellar fracture using non-absorbable suture cerclage and nickel-titanium patellar concentrator (Ni-Ti PC). Methods: Twenty-nine consecutive patients with displaced comminuted patellar fractures accepted internal fixation procedure using Ni-Ti PC augmented with different types of non-absorbable suture cerclage. During follow-up, the clinical grading scales of Bostman, including range of movement, pain, work, atrophy, assistance in walking, effusion, giving way, and stair-climbing, were used to evaluate the clinical results. Complications including implant loosening, fragment displacement, bone nonunion, infection, breakage of the implants, painful hardware, and post-traumatic osteoarthritis were also assessed. Results: Patients were followed up for a mean period of 27 months. The bone union radiographically occurred approximately 2.5 months without implant loosening and fragment displacement. According to Bostman method, satisfactory results were obtained, and the mean score at final follow-up was 28 (range 20-30) points. Twenty-two patients with excellent results had mean score of 29.8 +/- 0.5 (range 28-30) and seven patients with good results had mean score of 22.7 +/- 3.14 (range 20-27). No postoperative complications, such as infection, dislocation, breakage of the implants, painful hardware, and post-traumatic osteoarthritis, were observed. Conclusion: Ni-Ti PC fixation with non-absorbable suture cerclage is a feasible approach for comminuted patellar fractures. Firm fixation with this technique resulted in satisfactory outcomes without obvious complications. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1974 / 1979
页数:6
相关论文
共 50 条
  • [31] LAYER CLOSURE OF LAPAROTOMY WOUNDS WITH ABSORBABLE AND NON-ABSORBABLE SUTURE MATERIALS
    IRVIN, TT
    KOFFMAN, CG
    DUTHIE, HL
    [J]. BRITISH JOURNAL OF SURGERY, 1976, 63 (10) : 793 - 796
  • [32] Transverse patellar fracture fixation with tape cerclage in a patient with a history of complicated contralateral patellar fracture fixation with metallic hardware
    Monaco, Edoardo
    Caperna, Ludovico
    Relli, Silvia Ca Rda
    Carrozzo, Alessandro
    Annibaldi, Alessandro
    Marzilli, Fabio
    Bruni, Giorgio
    Ferretti, Andrea
    [J]. INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2020, 10 (06): : 307 - 313
  • [33] Can multiple miniplates improve the treatment of comminuted patellar fracture?
    Yoo, Seung Jin
    Ok, Seungwoo
    Lee, Jaeryun
    Choi, Sungwook
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [34] Can multiple miniplates improve the treatment of comminuted patellar fracture?
    Seung Jin Yoo
    Seungwoo Ok
    Jaeryun Lee
    Sungwook Choi
    [J]. BMC Musculoskeletal Disorders, 24
  • [35] Surgical treatment of comminuted die-punch patellar fracture
    Sun, YQ
    Stephen, M
    Meinhard, BP
    [J]. ORTHOPEDICS, 2001, 24 (10) : 947 - 950
  • [36] Management and Outcome of Elderly Patients With Patellar Fracture Treated With Novel Modified Cerclage Wiring
    Li, Lin
    Zhang, Qing
    Tao, Fulin
    Wang, Dawei
    Dong, Jinlei
    Zhou, Dongsheng
    Song, Wenhao
    [J]. GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2023, 14
  • [37] Patellar Fracture Fixation With Cannulated Compression Screws and FiberTape Cerclage
    Posner, Andrew D.
    Hutchinson, Ian
    Zimmerman, Joseph
    [J]. ARTHROSCOPY TECHNIQUES, 2021, 10 (06): : E1447 - E1453
  • [38] JEJUNAL CARCINOMA ASSOCIATED WITH NON-ABSORBABLE SUTURE MATERIAL
    LEINHARDT, DJ
    SMART, PJ
    HOWAT, JMT
    [J]. POSTGRADUATE MEDICAL JOURNAL, 1988, 64 (755) : 716 - 717
  • [39] Modified Tension Band Wiring Using Only Non-Absorbable Braided Polyblend Sutures for the Treatment of Patellar Fractures
    Itro, Annalisa
    De Cicco, Annalisa
    Conza, Gianluca
    Schiavo, Luca
    Garofalo, Niccolo
    Braile, Adriano
    Nappi, Francesco
    Toro, Giuseppe
    [J]. SURGICAL TECHNIQUES DEVELOPMENT, 2024, 13 (02): : 227 - 236
  • [40] Periprosthetic Patellar Fracture Fixation Using Suture Anchors
    Maniar, Rajesh N.
    Nayak, Ravi M.
    Vatchha, Shahrookh
    Singhi, Tushar
    [J]. ORTHOPEDICS, 2013, 36 (11) : E1470 - E1473