Management of comminuted patellar fracture with non-absorbable suture cerclage and Nitinol patellar concentrator

被引:15
|
作者
Lue, Tan Hong [1 ]
Feng, Liu Wei [2 ]
Jun, Wang Ming [1 ]
Yin, Li Wu [1 ]
机构
[1] Luoyang Orthoped Traumatol Hosp, Dept Orthoped Surg, Luoyang 471002, Peoples R China
[2] Jiangsu Univ, Changzhou Wujin Hosp, Dept Orthoped Surg, Changzhou 213002, Peoples R China
关键词
Patellar fracture; Comminuted fracture; Non-absorbable suture cerclage; Nitinol patellar concentrator; BRAIDED POLYESTER SUTURE; FIXATION;
D O I
10.1016/j.injury.2014.10.008
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To evaluate the effectiveness and safety of a fixation technique for comminuted patellar fracture using non-absorbable suture cerclage and nickel-titanium patellar concentrator (Ni-Ti PC). Methods: Twenty-nine consecutive patients with displaced comminuted patellar fractures accepted internal fixation procedure using Ni-Ti PC augmented with different types of non-absorbable suture cerclage. During follow-up, the clinical grading scales of Bostman, including range of movement, pain, work, atrophy, assistance in walking, effusion, giving way, and stair-climbing, were used to evaluate the clinical results. Complications including implant loosening, fragment displacement, bone nonunion, infection, breakage of the implants, painful hardware, and post-traumatic osteoarthritis were also assessed. Results: Patients were followed up for a mean period of 27 months. The bone union radiographically occurred approximately 2.5 months without implant loosening and fragment displacement. According to Bostman method, satisfactory results were obtained, and the mean score at final follow-up was 28 (range 20-30) points. Twenty-two patients with excellent results had mean score of 29.8 +/- 0.5 (range 28-30) and seven patients with good results had mean score of 22.7 +/- 3.14 (range 20-27). No postoperative complications, such as infection, dislocation, breakage of the implants, painful hardware, and post-traumatic osteoarthritis, were observed. Conclusion: Ni-Ti PC fixation with non-absorbable suture cerclage is a feasible approach for comminuted patellar fractures. Firm fixation with this technique resulted in satisfactory outcomes without obvious complications. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1974 / 1979
页数:6
相关论文
共 50 条
  • [21] Split Fracture: A Complication of Cerclage Wiring of Acute Patellar Fracture
    Lo, Cho Yau
    Lui, Tun Hing
    Sit, Yan Kit
    [J]. ARCHIVES OF TRAUMA RESEARCH, 2014, 3 (03)
  • [22] ABSORBABLE OR NON-ABSORBABLE SUTURE MATERIALS FOR CLOSURE OF THE DURA MATER
    VALLFORS, B
    HANSSON, HA
    SVENSSON, J
    [J]. NEUROSURGERY, 1981, 9 (04) : 407 - 413
  • [23] Absorbable versus non-absorbable suture in carpal tunnel decompression
    Erel, E
    Pleasance, PI
    Ahmed, O
    Hart, NB
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (02): : 157 - 158
  • [24] Arthroscopic Assessment for Patellar Injuries and Novel Suture Repair of Patellar Fracture in a Cat
    Cusack, Lara
    Johnson, Matthew
    [J]. JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2013, 49 (04) : 267 - 272
  • [25] The clinical outcome of the reduction of the patellar inferior pole fracture with wire cerclage through a generated bone hole, in combination with patellar concentrator: a retrospective comparative study
    Rong Chen
    Hong Cao
    Zhibo Sun
    Liangbo Jiang
    Xiangwei Li
    Lin Zhao
    Xinghui Liu
    [J]. Journal of Orthopaedic Surgery and Research, 17
  • [26] The clinical outcome of the reduction of the patellar inferior pole fracture with wire cerclage through a generated bone hole, in combination with patellar concentrator: a retrospective comparative study
    Chen, Rong
    Cao, Hong
    Sun, Zhibo
    Jiang, Liangbo
    Li, Xiangwei
    Zhao, Lin
    Liu, Xinghui
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [27] A COMPARISON OF SYNTHETIC ABSORBABLE SUTURE WITH SYNTHETIC NON-ABSORBABLE SUTURE FOR CONSTRUCTION OF TRACHEAL ANASTOMOSES
    GIBBONS, JA
    PENISTON, RL
    RAFLO, CP
    DIAMOND, SS
    AARON, BL
    [J]. CHEST, 1981, 79 (03) : 340 - 342
  • [28] COMPARISON OF SYNTHETIC ABSORBABLE SUTURE WITH SYNTHETIC NON-ABSORBABLE SUTURE FOR CONSTRUCTION OF TRACHEAL ANASTAMOSES
    GIBBONS, JA
    PENISTON, RL
    RAFLO, CP
    DIAMOND, SS
    AARON, BL
    [J]. CHEST, 1979, 76 (03) : 352 - 352
  • [29] Butala technique: polyglactin 910 suture repair of comminuted patellar fractures
    Butala, Rajendaprasad R.
    Khedekar, Ravindra G.
    Nagara, Michael P. na
    Arora, Manit
    Yadav, Siddhartha
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2016, 27 (01): : 113 - 116
  • [30] The Effect of Absorbable and Non-absorbable Scleral Suture on Strabismus Surgery in the Rabbits
    Shin, Dong-Hoon
    Ryu, Won Yeol
    Jung, Jae Ho
    [J]. CURRENT EYE RESEARCH, 2020, 45 (10) : 1252 - 1256