Biomechanical investigation on refixation of tuberosities on shoulder prostheses

被引:0
|
作者
Fleischer, J. [1 ]
Schleyer, A. [2 ]
Nassutt, R. [3 ]
Grundei, H. [3 ]
Grittner, U. [4 ]
Hopp, S. J. [5 ]
机构
[1] Marienkrankenhaus St Wendel, Klin Orthopadie & Unfallchirurg, D-66606 St Wendel, Germany
[2] FH Lubeck, Biomech Labor, Lubeck, Germany
[3] ESKA Implants AG, Abt Forsch & Entwicklung, Lubeck, Germany
[4] Charite Univ Med Berlin, Inst Biometrie & Klin Epidemiol, Berlin, Germany
[5] Univ Klinikum Saarlandes, Klin Unfall Hand & Wiederherstellungschirurg, Homburg, Germany
来源
UNFALLCHIRURG | 2010年 / 113卷 / 08期
关键词
Proximal humerus fracture; Shoulder endoprosthesis; Tuberosity refixation; Biomechanical tests; Suture materials; PROXIMAL HUMERUS; PRIMARY HEMIARTHROPLASTY; GREATER TUBEROSITY; PROGNOSTIC-FACTORS; FRACTURES; ARTHROPLASTY; HEAD; FIXATION; PART;
D O I
10.1007/s00113-010-1817-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Elderly patients suffering from complex, non-reconstructable fractures of the proximal humerus are commonly treated by primary implantation of a shoulder endoprosthesis. One of the most critical factors for success or failure of treatment is still the refixation of the tuberosities. Using sheep infraspinatus tendons with attached tuberosities three different suture materials were investigated. For 2 of the suture materials 4 tests were accomplished and 5 tests were carried out for the third suture material. A material testing machine was used to perform cyclic loading tests (20 mm/min, F-min = 50 N, F-max = 100 N, respectively after 50 cycles: F-max + 50 N until failure). The results showed large variations in the average maximum forces (152.4 N for suture 1, 219.9 N for suture 2 and 452.3 N for suture 3). All tests showed a high initial lengthening and caused incision-like defects in the bone or tendon and led to failure and high displacement of the tuberosities. Due to these results suture materials have a limited usefulness for refixation of tuberosities as an increased risk of obstruction for bony consolidation can result.
引用
收藏
页码:641 / 646
页数:6
相关论文
共 50 条
  • [21] Corrections Regarding "Investigation of Morphological and Biomechanical Properties of the Scapula for Shoulder Joint"
    Cini, Nilgun Tuncel
    Sak, Nazan Guner
    Babacan, Serdar
    Ari, Ilknur
    MEDENIYET MEDICAL JOURNAL, 2024, 39 (01): : 68 - 69
  • [22] BIOMECHANICAL STUDIES ON SHELL PROSTHESES
    GERNGROSS, H
    CLAES, L
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1982, 120 (04): : 406 - 406
  • [23] A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation
    Thore Zantop
    Anne Kathleen Eggers
    Volker Musahl
    Andre Weimann
    Joachim Hassenpflug
    Wolf Petersen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2004, 12 : 317 - 324
  • [24] Reverse shoulder arthroplasty for acute fractures in the elderly: is it worth reattaching the tuberosities?
    Boileau, Pascal
    Alta, Tjarco D.
    Decroocq, Lauryl
    Sirveaux, Francois
    Clavert, Philippe
    Favard, Luc
    Chelli, Mikael
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (03) : 437 - 444
  • [25] Complications of unconstrained shoulder prostheses
    Gonzalez, Jean-Francois
    Alami, Ghassan B.
    Baque, Francois
    Walch, Gilles
    Boileau, Pascal
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) : 666 - 682
  • [26] THE RADIOLOGY OF TOTAL SHOULDER PROSTHESES
    FELDMAN, F
    SEMINARS IN ROENTGENOLOGY, 1986, 21 (01) : 47 - 65
  • [27] A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation
    Zantop, T
    Eggers, AK
    Musahl, V
    Weimann, A
    Hassenpflug, J
    Petersen, W
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (04) : 317 - 324
  • [28] Root tear of the meniscus: biomechanical evaluation of an arthroscopic refixation technique
    Rosslenbroich, Steffen B.
    Borgmann, J.
    Herbort, M.
    Raschke, M. J.
    Petersen, W.
    Zantop, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 111 - 115
  • [29] UNCONSTRAINED TOTAL SHOULDER PROSTHESES
    COFIELD, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (173) : 97 - 108
  • [30] 3D optical measurement of relative displacement for the tuberosities in the shoulder prosthesis
    YAO XueFeng 1
    2 Beijing Jishuitan Hospital
    Science China(Physics,Mechanics & Astronomy), 2011, Mechanics & Astronomy)2011 (04) : 647 - 652