A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation

被引:0
|
作者
Thore Zantop
Anne Kathleen Eggers
Volker Musahl
Andre Weimann
Joachim Hassenpflug
Wolf Petersen
机构
[1] Christian-Albrechts-University Kiel,Department of Orthopaedic Surgery
[2] University of Pittsburgh,Department of Orthopedic Surgery
[3] Westfälische Wilhelms-University Münster,Department of Trauma, Hand and Reconstructive Surgery
关键词
Meniscus refixation; Meniscus Arrow; Biodegradable implants; Contour Arrow; Bucket handle tear;
D O I
暂无
中图分类号
学科分类号
摘要
All-inside repair devices have been developed to overcome the disadvantages of conventional suture techniques (such as vein and nerve damage and increased OR time). The Contour Meniscus Arrow is a second generation of the first biodegradable all-inside implant, the Meniscus Arrow. The aim of this study was to compare the biomechanical properties of the Contour Meniscus Arrow to the first-generation Meniscus Arrow and vertical or horizontal suture techniques. In fresh frozen bovine menisci, initial fixation strength, stiffness and failure mode of four different meniscus refixation techniques (Meniscus Arrow, Contour Meniscus Arrow, vertical and horizontal 2–0 Ethibond suture techniques) were evaluated in a computer-based material-testing machine at a rate of 12.5 mm/s. Vertical meniscus sutures showed the highest initial fixation strength, followed by the horizontal suture technique and the Contour Arrow. The Meniscus Arrow showed inferior pull-out strength. Subjecting the different refixation techniques to cyclic testing decreased the fixation strength in all groups. The modified Meniscus Anchor (Contour Arrow) provides biomechanical properties that are superior (pull-out strength) or similar (stiffness) compared to the first biodegradable all-inside implant, the Meniscus Arrow. The pull-out strength of the Contour Arrow was comparable to the pull-out strength reported for horizontal meniscus sutures in the literature. These biomechanical characteristics of this new implant justify clinical use.
引用
收藏
页码:317 / 324
页数:7
相关论文
共 50 条
  • [1] A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation
    Zantop, T
    Eggers, AK
    Musahl, V
    Weimann, A
    Hassenpflug, J
    Petersen, W
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (04) : 317 - 324
  • [2] Biodegradable meniscus refixation devices: a biomechanical study
    Seil, R
    Rupp, S
    Jurecka, C
    Georg, T
    Kohn, D
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2003, 89 (01): : 35 - 43
  • [3] Root tear of the meniscus: biomechanical evaluation of an arthroscopic refixation technique
    Steffen B. Rosslenbroich
    J. Borgmann
    M. Herbort
    M. J. Raschke
    W. Petersen
    T. Zantop
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 111 - 115
  • [4] Root tear of the meniscus: biomechanical evaluation of an arthroscopic refixation technique
    Rosslenbroich, Steffen B.
    Borgmann, J.
    Herbort, M.
    Raschke, M. J.
    Petersen, W.
    Zantop, T.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (01) : 111 - 115
  • [5] Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors - Biomechanical evaluation of new meniscus refixation systems
    Zantop, T
    Eggers, AK
    Weimann, A
    Hassenpflug, J
    Petersen, W
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (04): : 863 - 869
  • [6] Refixation of the meniscus with the SD meniscal staple: a comparative biomechanical study on cadaver knees
    Schoettle, PB
    Fredrich, H
    Steinhauser, E
    Imhoff, AB
    UNFALLCHIRURG, 2003, 106 (02): : 114 - 120
  • [7] A Superolaterally Placed Anchor for Subscapularis "Leading-Edge" Refixation: A Biomechanical Study
    Dyrna, Felix
    Beitzel, Knut
    Pauzenberger, Leo
    Dwyer, Corey R.
    Obopilwe, Elifho
    Mazzocca, Augustus D.
    Imhoff, Andreas B.
    Braun, Sepp
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (05): : 1306 - +
  • [8] Suture anchor and transtibial pullout refixation of the posterior medial meniscus root tears restore tibiofemoral contact pressure and area to intact meniscus levels
    Itthipanichpong, Thun
    Choentrakool, Chitapoom
    Limskul, Danaithep
    Thamrongskulsiri, Napatpong
    Tanpowpong, Thanathep
    Virulsri, Chanyaphan
    Tangpornprasert, Pairat
    Kuptniratsaikul, Somsak
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024,
  • [9] Biomechanical test comparing the load to failure of the biodegradable meniscus arrow versus meniscal suture
    Song, EK
    Lee, KB
    ARTHROSCOPY, 1999, 15 (07): : 726 - 732
  • [10] Biodegradable implants in soft tissue refixation:: Experimental evaluation, clinical experience, and future needs
    Südkamp, NP
    Kääb, MJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 : 17 - 24