Computed Tomography-Based Stiffness Measures of Trabecular Bone Microstructure: Cadaveric Validation and In Vivo Application

被引:4
|
作者
Guha, Indranil [1 ]
Zhang, Xialiou [1 ]
Rajapakse, Chamith S. [2 ,3 ]
Letuchy, Elena M. [4 ]
Chang, Gregory [5 ]
Janz, Kathleen F. [6 ]
Torner, James C. [4 ]
Levy, Steven M. [4 ,7 ]
Saha, Punam K. [1 ,8 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Dept Orthoped Surg, Philadelphia, PA 19104 USA
[4] Univ Iowa, Dept Epidemiol, Iowa City, IA USA
[5] NYU, Dept Radiol, Grossman Sch Med, 560 1st Ave, New York, NY 10016 USA
[6] Univ Iowa, Dept Hlth & Human Physiol, Iowa City, IA USA
[7] Univ Iowa, Dept Prevent & Community Dent, Iowa City, IA USA
[8] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
关键词
ANSYS SOFTWARE; ASH DENSITY; BODY SIZE AND COMPOSITION; COMPRESSIVE AND SHEAR LOADING; CT IMAGING; MICROSTRUCTURE; NONLINEAR FEA; OSTEOPOROSIS; TB STIFFNESS; TRABECULAR BONE; VON MISES STRESS; YOUNG'S MODULUS; FINITE-ELEMENT-ANALYSIS; MINERAL DENSITY; LEAN MASS; MECHANICAL-PROPERTIES; DISTAL RADIUS; FAT MASS; HR-PQCT; COMPUTATIONAL BIOMECHANICS; CANCELLOUS BONE; STRENGTH;
D O I
10.1002/jbm4.10627
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Osteoporosis causes bone fragility and elevates fracture risk. Applications of finite element (FE) analysis (FEA) for assessment of trabecular bone (Tb) microstructural strength at whole-body computed tomography (CT) imaging are limited due to challenges with Tb microstructural segmentation. We present a nonlinear FEA method for distal tibia CT scans evading binary segmentation of Tb microstructure, while accounting for bone microstructural distribution. First, the tibial axis in a CT scan was aligned with the FE loading axis. FE cubic mesh elements were modeled using image voxels, and CT intensity values were calibrated to ash density defining mechanical properties at individual elements. For FEA of an upright volume of interest (VOI), the bottom surface was fixed, and a constant displacement was applied at each vertex on the top surface simulating different loading conditions. The method was implemented and optimized using the ANSYS software. CT-derived computational modulus values were repeat scan reproducible (intraclass correlation coefficient [ICC] >= 0.97) and highly correlated (r >= 0.86) with the micro-CT (mu CT)-derived values. FEA-derived von Mises stresses over the segmented Tb microregion were significantly higher (p < 1 x 10(-11)) than that over the marrow space. In vivo results showed that both shear and compressive modulus for males were higher (p < 0.01) than for females. Effect sizes for different modulus measures between males and females were moderate-to-high (>= 0.55) and reduced to small-to-negligible (<0.40) when adjusted for pure lean mass. Among body size and composition attributes, pure lean mass and height showed highest (r is an element of [0.45 0.56]) and lowest (r is an element of [0.25 0.39]) linear correlation, respectively, with FE-derived modulus measures. In summary, CT-based nonlinear FEA provides an effective surrogate measure of Tb microstructural stiffness, and the relaxation of binary segmentation will extend the scope for FEA in human studies using in vivo imaging at relatively low-resolution. (c) 2022 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Metaversion can reliably predict humeral head version: A computed tomography-based validation study
    Athwal, George S.
    MacDermid, Joy C.
    Goel, Danny P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (08) : 1145 - 1149
  • [42] Microstructure of the hyoid bone based on micro-computed tomography findings
    Wang, Xing
    Wang, Chaoqun
    Zhang, Shaojie
    Wang, Wei
    Li, Xiaohe
    Gao, Shang
    Li, Kun
    Chen, Jie
    Wang, Haiyan
    Chen, Lianxiang
    Shi, Jun
    Liu, Xiaoling
    Li, Zhi-Jun
    MEDICINE, 2020, 99 (44) : E22246
  • [43] Multidetector Computed Tomography-Based Microstructural Analysis Reveals Reduced Bone Mineral Content and Trabecular Bone Changes in the Lumbar Spine after Transarterial Chemoembolization Therapy for Hepatocellular Carcinoma
    Takasu, Miyuki
    Yamagami, Takuji
    Nakamura, Yuko
    Komoto, Daisuke
    Kaichi, Yoko
    Tani, Chihiro
    Date, Shuji
    Kiguchi, Masao
    Awai, Kazuo
    PLOS ONE, 2014, 9 (10):
  • [44] The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure
    Tjong, Willy
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Majumdar, Sharmila
    MEDICAL PHYSICS, 2012, 39 (04) : 1893 - 1903
  • [45] Quantifications of Mandibular Trabecular Bone Microstructure Using Cone Beam Computed Tomography for Age Estimation: A Preliminary Study
    Tabassum, Arshiya
    Singh, Mansharan Kaur Chainchel
    Ibrahim, Norliza
    Ramanarayanan, Subramaniam
    Yusof, Mohd Yusmiaidil Putera Mohd
    BIOLOGY-BASEL, 2022, 11 (10):
  • [46] Computed tomography-based skeletal segmentation for quantitative PET metrics of bone involvement in multiple myeloma
    Takahashi, Maria E. S.
    Mosci, Camila
    Souza, Edna M.
    Brunetto, Sergio Q.
    de Souza, Carmino
    Pericole, Fernando V.
    Lorand-Metze, Irene
    Ramos, Celso D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (04) : 377 - 382
  • [47] Combining Computed Tomography-Based Bone Density Assessment with FRAX Screening in Men with Prostate Cancer
    McDonald, Andrew M.
    Jones, Joseph A.
    Cardan, Rex A.
    Saag, Kenneth S.
    Mayhew, David L.
    Fiveash, John B.
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (04) : 430 - 435
  • [48] Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact
    Meagher, Matthew J.
    Parwani, Rachna N.
    Virdi, Amarjit S.
    Sumner, Dale R.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (03) : 979 - 986
  • [49] Classification of bone flap resorption after cranioplasty: a proposal for a computed tomography-based scoring system
    Tommi K. Korhonen
    Niina Salokorpi
    Pasi Ohtonen
    Petri Lehenkari
    Willy Serlo
    Jaakko Niinimäki
    Sami Tetri
    Acta Neurochirurgica, 2019, 161 : 473 - 481
  • [50] Computed Tomography-Based Bone Density Assessment for Men With Prostate Cancer: Not Ready for Prime Time
    Schousboe, John T.
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (04) : 407 - 408