Evaluation criteria for film based intensity modulated radiation therapy quality assurance

被引:7
|
作者
Anjum, Muhammad Naeem [1 ,2 ]
Parker, William [2 ]
Ruo, Russell [2 ]
Afzal, Muhammad [1 ,3 ]
机构
[1] Islamia Univ Bahawalpur, Dept Phys, Bahawalpur, Pakistan
[2] McGill Univ, Ctr Hlth, Montreal Gen Hosp, Dept Med Phys, Montreal, PQ H3C 1A4, Canada
[3] Univ Dundee, Ninewells Hosp & Med Sch, Dept Med Phys, Dundee DD1 9SY, Scotland
来源
关键词
IMRT; Gafchromic (TM) EBT; gamma-Histograms; Film dosimetry; EBT FILM; RADIOTHERAPY; DOSIMETRY; CARCINOMA; CANCER; IMRT; IMPLEMENTATION; VERIFICATION; SENSITIVITY; DELIVERY;
D O I
10.1016/j.ejmp.2009.06.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to use different gamma histogram criteria for the comparison of planned dose with irradiated dose distribution and find that what percent of pixels passing a certain criteria imitate a good quality plan. The dose was calculated for 156 patients by inverse planning optimization using the Corvus treatment planning system. Gaf-3 chromic films in combination with 2571 0.6 cm(3) Farmer type ionization chamber and Farmer 2570/1 electrometer from NE Technology were used to measure the delivered dose in solid water phantom. All the measurements were performed on Varian CL21EX linear accelerator (Varian Medical. Systems, Palo Alto, CA) fitted with a Millennium 120 leaf collimator. In this study the mean value of the percent of passing pixels within the region of interest under the criterion of 3% DD and 3 mm DTA is 90.2 +/- 7.1% for head and neck cases and 92.2 +/- 5.8% for non-head and neck cases. If we choose the criteria of 3% DD and 3 mm DTA then 96.3% head and neck plans have the percent of passing pixels >= 75% and 95.1% non-head and neck plans have the percent of passing pixels >= 80%. It is evident from the results of this study that the criterion of 5% DD and 3 mm DTA with the percent of passing pixels >= 90 for non-head and neck cases while the percent of passing pixels >= 85 for head and neck cases endorse that a plan is good. The results of this study may be useful for other institutions which use verification software and EBT films for patient specific IMRT QA. (C) 2009 Associazione Itatiana di Fisica Medica. Published by Elsevier Ltd. All. rights reserved.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Towards automated quality assurance for intensity modulated radiation therapy: Film densitometry
    Low, DA
    Markman, J
    Dempsey, JF
    Mutic, S
    Klein, EE
    Grigereit, TE
    Purdy, JA
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 184 - 187
  • [2] Analysis of film registration techniques in intensity modulated radiation therapy quality assurance
    Harris, C.
    Ramsey, C.
    Seibert, R.
    Robison, B.
    Chase, D.
    Whitaker, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2331 - 2331
  • [3] Quality assurance of intensity-modulated radiation therapy
    Palta, Jatinder R.
    Li, Chihray
    Li, Jonathan G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S108 - S112
  • [4] Strategies for quality assurance of intensity modulated radiation therapy
    Benedek, Hunor
    Isacsson, Ulf
    Olevik-Dunder, Maria
    Westermark, Mathias
    Hallstrom, Per
    Olofsson, Jorgen
    Gustafsson, Magnus
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [5] Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy
    Ju, Sang Gyu
    Han, Youngyih
    Kum, Oyeon
    Cheong, Kwang-Ho
    Shin, Eun Hyuk
    Shin, Jung Suk
    Kim, Jin Sung
    Ahn, Yong Chan
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2925 - 2933
  • [6] Comparison of radiographic film, radiochromic film, and CR plates for intensity modulated radiation therapy quality assurance
    Harris, C.
    Ramsey, C.
    Seibert, R.
    Robison, B.
    Chase, D.
    Whitaker, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2429 - 2430
  • [7] Clinical applications and quality assurance of intensity modulated radiation therapy
    Grimm, SYL
    Ndlovu, A
    Cheng, CW
    Chow, M
    Wong, JR
    [J]. CANCER JOURNAL, 2001, 7 (06): : 547 - 547
  • [8] Quality assurance of helical tomotherapy intensity modulated radiation therapy
    Xu, Shouping
    Deng, Xiaowu
    Dai, Xiangkun
    Wang, Lianyuan
    Wang, Yunlai
    Xie, Chuanbin
    Ge, Ruigang
    Gong, Hanshun
    [J]. APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 447 - +
  • [9] A Survey of Quality Assurance in Intensity-Modulated Radiation Therapy in Japan
    Nakamura, M.
    Ono, T.
    Akimoto, M.
    Mukumoto, N.
    Ishihara, Y.
    Utsunomiya, S.
    Shiinoki, T.
    Miyabe, Y.
    Sato, S.
    Monzen, H.
    Hiraoka, M.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Design of an anthropomorphic intensity modulated radiation therapy quality assurance phantom
    Radford, DA
    Followill, DS
    Hanson, WF
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 197 - 200