Critical flow venturis (CFVs) can be used to measure flow under transient pressure and flow conditions with uncertainties of 0.13% or less (95% confidence level). Blow-down tests transferred 630 g of nitrogen during a 100 s interval from an unregulated gas cylinder (initially at 10 MPa) through a heat exchanger and a CFV into a known collection volume. Fast pressure and temperature sensors were used to calculate the CFV flow. The integrated CFV mass flows, integral (m) over dot dt, averaged 0.04% smaller than the mass Delta rho V of the collected gas. The heat exchanger was essential to the excellent agreement; without it, the percentage difference between integral (m) over dot dt and Delta rho V was -0.38%. We conclude that even under transient conditions, a properly instrumented CFV can be used as a reference flowmeter to evaluate other flowmeter types or to test gaseous fuel dispensers in the field.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Adsorption under transient conditions
    Ciprian, J
    Maurer, S
    Ruppel, W
    Wegerle, U
    CHEMIE INGENIEUR TECHNIK, 2005, 77 (1-2) : 61 - 64
  • [42] Experimental investigation of debris damming loads under transient supercritical flow conditions
    Stolle, Jacob
    Takabatake, Tomoyuki
    Nistor, Ioan
    Mikami, Takahito
    Nishizaki, Shinsaku
    Hamano, Go
    Ishii, Hidenori
    Shibayama, Tomoya
    Goseberg, Nils
    Petriu, Emil
    COASTAL ENGINEERING, 2018, 139 : 16 - 31
  • [43] Operation of Natural Gas Pipeline Networks With Storage Under Transient Flow Conditions
    Hari, Sai Krishna Kanth
    Sundar, Kaarthik
    Srinivasan, Shriram
    Zlotnik, Anatoly
    Bent, Russell
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2022, 30 (02) : 667 - 679
  • [44] Bromide and herbicide transport under steady-state and transient flow conditions
    Meyer-Windel, S
    Lennartz, B
    Widmoser, P
    EUROPEAN JOURNAL OF SOIL SCIENCE, 1999, 50 (01) : 23 - 33
  • [45] APPARATUS FOR SIMULTANEOUS TEMPERATURE AND HEAT-FLOW MEASUREMENTS UNDER TRANSIENT CONDITIONS
    LECLERCQ, D
    THERY, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (03): : 374 - 380
  • [46] Head and flux variability in heterogeneous unsaturated soils under transient flow conditions
    Ferrante, M
    Yeh, TCJ
    WATER RESOURCES RESEARCH, 1999, 35 (05) : 1471 - 1479
  • [47] Head and flux variability in heterogeneous unsaturated soils under transient flow conditions
    Ferrante, Marco
    Yeh, T.-C. Jim
    Water Resources Research, 35 (05): : 1471 - 1479
  • [48] PERFORMANCE OF INWARD RADIAL FLOW TURBINE UNDER UNSTEADY FLOW CONDITIONS.
    Miyashita, Takeshi
    Tomita, Tetsuya
    Ishihara, Daiji
    Ishikawajima-Harima Giho/IHI Engineering Review, 1974, 7 (01): : 10 - 22
  • [49] A simple model of axial flow cyclone performance under laminar flow conditions
    Maynard, A.D., 1600, Elsevier Science Ltd, Exeter (31):
  • [50] Investigation of the mixed flow turbine performance under inlet pulsating flow conditions
    Hamel, Mohammed
    Abidat, Miloud
    Litim, Sid Ali
    COMPTES RENDUS MECANIQUE, 2012, 340 (03): : 165 - 176