Performance of critical flow venturis under transient conditions

被引:8
|
作者
Wright, John D. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
blow-down test; critical flow venturi; critical nozzle; fuel dispenser; transient flow;
D O I
10.1088/0957-0233/21/5/055404
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Critical flow venturis (CFVs) can be used to measure flow under transient pressure and flow conditions with uncertainties of 0.13% or less (95% confidence level). Blow-down tests transferred 630 g of nitrogen during a 100 s interval from an unregulated gas cylinder (initially at 10 MPa) through a heat exchanger and a CFV into a known collection volume. Fast pressure and temperature sensors were used to calculate the CFV flow. The integrated CFV mass flows, integral (m) over dot dt, averaged 0.04% smaller than the mass Delta rho V of the collected gas. The heat exchanger was essential to the excellent agreement; without it, the percentage difference between integral (m) over dot dt and Delta rho V was -0.38%. We conclude that even under transient conditions, a properly instrumented CFV can be used as a reference flowmeter to evaluate other flowmeter types or to test gaseous fuel dispensers in the field.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] TRANSIENT FILM BOILING UNDER TRANSIENT CONDITIONS RELATED TO VAPOR EXPLOSION (EFFECTS OF TRANSIENT FLOW AND FRAGMENTATION UNDER A SHOCK PRESSURE)
    INOUE, A
    TAKAHASHI, K
    TAKAHASHI, M
    MATSUZAKI, M
    NUCLEAR ENGINEERING AND DESIGN, 1995, 155 (1-2) : 55 - 66
  • [22] Flow transient critical heat flux in a narrow rectangular channel under downward flow
    Kim, Huiyung
    Kang, Jinhoon
    Ahn, Taehwan
    Jeong, Jae Jun
    Yun, Byongjo
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 159
  • [23] PERFORMANCE OF A ROTATING BIOLOGICAL CONTACTOR UNDER TRANSIENT LOADING CONDITIONS
    FILION, MP
    MURPHY, KL
    STEPHENSON, JP
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1979, 51 (07): : 1925 - 1933
  • [24] Performance of three algorithms for frequency measurement under transient conditions
    Sorrentino, Elmer
    Carvalho, Raul
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (10) : 1191 - 1196
  • [25] Transient hovering performance of hummingbirds under conditions of maximal loading
    Chai, P
    Chen, JSC
    Dudley, R
    JOURNAL OF EXPERIMENTAL BIOLOGY, 1997, 200 (05): : 921 - 929
  • [26] Performance of a rotating biological contactor under transient loading conditions
    Filion, M.P.
    Murphy, K.L.
    Stephenson, J.P.
    Journal of the Water Pollution Control Federation, 1979, 51 (07): : 1925 - 1933
  • [27] Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL
    Meehan, Nicholas A.
    Seo, Seok Bin
    Howard, Trevor K.
    Brown, Nicholas R.
    NUCLEAR TECHNOLOGY, 2023, 209 (08) : 1164 - 1188
  • [28] Critical conditions of transient stability
    Yorino N.
    Popov E.
    Yura N.
    Rokubako R.
    Nakamura Y.
    Sasaki Y.
    Zoka Y.
    Sugiyama H.
    IEEJ Transactions on Power and Energy, 2019, 139 (05): : 349 - 355
  • [29] Theoretical prediction model of transient performance for a mixed flow pump under fast start-up conditions
    Liu, Ming
    Han, Yadong
    Tan, Lei
    Lu, Yangping
    Ma, Can
    Gou, Jinlan
    PHYSICS OF FLUIDS, 2023, 35 (02)
  • [30] Lagrangian analysis of transport in heterogeneous formations under transient flow conditions
    Dagan, G
    Bellin, A
    Rubin, Y
    WATER RESOURCES RESEARCH, 1996, 32 (04) : 891 - 899