Performance of critical flow venturis under transient conditions

被引:8
|
作者
Wright, John D. [1 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
关键词
blow-down test; critical flow venturi; critical nozzle; fuel dispenser; transient flow;
D O I
10.1088/0957-0233/21/5/055404
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Critical flow venturis (CFVs) can be used to measure flow under transient pressure and flow conditions with uncertainties of 0.13% or less (95% confidence level). Blow-down tests transferred 630 g of nitrogen during a 100 s interval from an unregulated gas cylinder (initially at 10 MPa) through a heat exchanger and a CFV into a known collection volume. Fast pressure and temperature sensors were used to calculate the CFV flow. The integrated CFV mass flows, integral (m) over dot dt, averaged 0.04% smaller than the mass Delta rho V of the collected gas. The heat exchanger was essential to the excellent agreement; without it, the percentage difference between integral (m) over dot dt and Delta rho V was -0.38%. We conclude that even under transient conditions, a properly instrumented CFV can be used as a reference flowmeter to evaluate other flowmeter types or to test gaseous fuel dispensers in the field.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Thermal boundary layers in critical flow venturis
    Wright, John D.
    Kang, Woong
    Johnson, Aaron N.
    Khromchenko, Vladimir B.
    Moldover, Michael R.
    Zhang, Liang
    Mickan, Bodo
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 81
  • [2] The effect of vibrational relaxation on the discharge coefficient of critical flow venturis
    Johnson, AN
    Wright, JD
    Nakao, S
    Merkle, CL
    Moldover, MR
    FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (04) : 315 - 327
  • [3] Performance of ABR flow control schemes under varying network conditions with transient analysis
    Hou, YT
    Yin, NY
    Panwar, SS
    NETWORKS: THE NEXT MILLENNINUM - THE IEEE SINGAPORE INTERNATIONAL CONFERENCE ON NETWORKS 1997, IEEE SICON'97, 1997, : 33 - 52
  • [4] Energy and momentum under critical flow conditions
    Di Nucci, C.
    Spena, A. Russo
    JOURNAL OF HYDRAULIC RESEARCH, 2011, 49 (01) : 127 - 130
  • [5] Energy and momentum under critical flow conditions
    Castro-Orgaz, Oscar
    Vicente Giraldez, Juan
    Luis Ayuso, Jose
    JOURNAL OF HYDRAULIC RESEARCH, 2008, 46 (06) : 844 - 848
  • [6] A study of turbulence under conditions of transient flow in a pipe
    He, S
    Jackson, JD
    JOURNAL OF FLUID MECHANICS, 2000, 408 : 1 - 38
  • [7] Bubble deformation in magma under transient flow conditions
    Ohashi, Masatoshi
    Ichihara, Mie
    Toramaru, Atsushi
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2018, 364 : 59 - 75
  • [8] Flow monitoring and permeability measurement under constant and transient flow conditions
    Heardman, E
    Lekakou, C
    Bader, MG
    COMPOSITES SCIENCE AND TECHNOLOGY, 2004, 64 (09) : 1239 - 1249
  • [9] Performance of Fully Grouted Piezometers under Transient Flow Conditions: Field Study and Numerical Results
    Marefat, Vahid
    Duhaime, Francois
    Chapuis, Robert P.
    Le Borgne, Vincent
    GEOTECHNICAL TESTING JOURNAL, 2019, 42 (02): : 433 - 456
  • [10] DIFFUSIONAL SAMPLER PERFORMANCE UNDER TRANSIENT EXPOSURE CONDITIONS
    EINFELD, W