Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time

被引:81
|
作者
Chee, F [1 ]
Fernando, T
van Heerden, PV
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Crawley, WA 6009, Australia
[2] Sir Charles Gairdner Hosp, Intens Care Unit, Nedlands, WA 6009, Australia
关键词
artificial pancreas; closed-loop glucose control; intravenous insulin infusion; sliding scale; subcutaneous blood glucose monitoring;
D O I
10.1109/TITB.2003.808509
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A study was conducted to determine if continuous subcutaneous glucose monitoring (from MiniMed CGMS) could be used in real-time to control blood sugar level (BSL) in patients with critical illness. A closed-loop control system was constructed to use CGMS in a real-time manner, coupled with. a proportional integral (PI) control algorithm based on a sliding scale approach, for automatic intravenous infusion of insulin to patients. A total of five subjects with high BSL (> 10 mmol/L) participated in formal studies of the closed-loop control system. Subjects were recruited from critically ill patients in the intensive care unit (ICU) after informed consent was obtained. Error grid analysis showed that 64.6% of the BSL readings as determined in real time using CGMS sensor, when compared to conventional BSL measurements on blood drawn from an arterial line, was clinically accurate (i.e., < 20% deviation from glucometer value). In the five patients who underwent closed-loop control, the controller managed to control only one patient's glycaemia without any manual intervention. Manual intervention was required due to the real-time sensor reading deviating more than 20% from the glucometer value, and also as a safety mechanism. Test on equality of mean and variance for BSL attained prior to, during, and post trial showed that the controller's performance was comparable to manual control. We conclude that the automatic sliding scale approach of closed-loop BSL control is feasible in patients in intensive care. More work is needed in the refinement of the algorithm and the improvement of real-time sensor accuracy.
引用
收藏
页码:43 / 53
页数:11
相关论文
共 50 条
  • [1] Experience with the Continuous Glucose Monitoring System (CGMS®) in critically ill patients
    Goldberg, P
    Inzucchi, S
    Siegel, M
    Halickman, J
    Cooper, D
    Sherwin, R
    DIABETES, 2003, 52 : A94 - A94
  • [2] Closed-loop control of blood glucose levels in critically ill patients
    Chee, F
    Fernando, T
    van Heerden, PV
    ANAESTHESIA AND INTENSIVE CARE, 2002, 30 (03) : 295 - 307
  • [3] ACCURACY AND RELIABILITY OF A SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING SYSTEM (CGMS) IN CRITICALLY ILL PATIENTS
    Brunner, R.
    Kitzberger, R.
    Miehsler, W.
    Herkner, H.
    Madl, C.
    Holzinger, U.
    INTENSIVE CARE MEDICINE, 2010, 36 : S171 - S171
  • [4] THE IMPACT OF REAL TIME CONTINUOUS GLUCOSE MONITORING ON GLUCOSE VARIABILITY IN CRITICALLY ILL PATIENTS
    Brunner, R.
    Kitzberger, R.
    Miehsler, W.
    Madl, C.
    Holzinger, U.
    INTENSIVE CARE MEDICINE, 2010, 36 : S331 - S331
  • [5] Impact of real-time continuous glucose monitoring on glucose variability in critically ill patients
    R Brunner
    R Kitzberger
    W Miehsler
    V Fuhrmann
    C Madl
    U Holzinger
    Critical Care, 14 (Suppl 1):
  • [6] Continuous glucose monitoring and closed-loop systems
    Hovorka, R
    DIABETIC MEDICINE, 2006, 23 (01) : 1 - 12
  • [7] THE IMPACT OF CONTINUOUS GLUCOSE MONITORING SYSTEMS ON GLUCOSE CONTROL IN CRITICALLY ILL PATIENTS
    Lu, Meizhu
    Kang, Yan
    Guo, Jun
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [8] Glucose control in non-critically ill inpatients with diabetes: towards closed-loop
    Thabit, H.
    Hovorka, R.
    DIABETES OBESITY & METABOLISM, 2014, 16 (06): : 500 - 509
  • [9] Real-Time Continuous Glucose Monitoring in Critically Ill Patients A prospective randomized trial
    Holzinger, Ulrike
    Warszawska, Joanna
    Kitzberger, Reinhard
    Wewalka, Marlene
    Miehsler, Wolfgang
    Herkner, Harald
    Madl, Christian
    DIABETES CARE, 2010, 33 (03) : 467 - 472
  • [10] Continuous post-operative blood glucose monitoring and control using a closed-loop system in patients undergoing hepatic resection
    Okabayashi, Takehiro
    Hnazaki, Kazuhiro
    Nishimori, Isao
    Sugimoto, Takeki
    Maeda, Hiromichi
    Yatabe, Tomoaki
    Dabanaka, Ken
    Kobayashi, Michiya
    Yamashita, Koichi
    DIGESTIVE DISEASES AND SCIENCES, 2008, 53 (05) : 1405 - 1410