Probabilistic finite element analysis of the uncemented hip replacement-effect of femur characteristics and implant design geometry

被引:72
|
作者
Dopico-Gonzalez, Carolina [1 ]
New, Andrew M. [1 ]
Browne, Martin [1 ]
机构
[1] Univ Southampton, Sch Engn Sci, Bioengn Res Grp, Southampton SO9 5NH, Hants, England
关键词
Total hip replacement; Finite element analysis; Probability analysis; HUMAN TRABECULAR BONE; PROXIMAL FEMUR; FEMORAL ANTEVERSION; MECHANICAL-PROPERTIES; COMPUTED-TOMOGRAPHY; FRACTURE PREDICTION; YIELD STRAIN; MODELS; PROSTHESES; STEM;
D O I
10.1016/j.jbiomech.2009.09.039
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the present study, a probabilistic finite element tool was assessed using an uncemented total hip replacement model. Fully bonded and frictional interfaces were investigated for combinations of three proximal femurs and two implant designs, the Proxima short stem and the IPS hip stem prostheses. The Monte Carlo method was used with two performance indicators: the percentage of bone volume that exceeded specified strain limits and the maximum nodal micromotion. The six degrees of freedom of bone-implant relative position, magnitude of the hip contact force (L), and spatial direction of L were the random variables. The distal portion of the proximal femurs was completely constrained and some of the main muscle forces acting in the hip were applied. The coefficients of the linear approximation between the random variables and the output were used as the sensitivity values. In all cases, bone-implant position related parameters were the most sensitive parameters. The results varied depending on the femur, the implant design and the interface conditions. Values of maximum nodal micromotion agreed with results from previous studies, confirming the robustness of the implemented computational tool. It was demonstrated that results from a single model study should not be generalised to the entire population of femurs and that bone variability is an important factor that should be investigated in such analyses. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:512 / 520
页数:9
相关论文
共 50 条
  • [21] Finite element method to evaluate effects of hip implant geometry on bone cement stress distribution
    Son, Yang W.
    Wentz, Douglas H.
    Levine, Danny L.
    Johnson, Todd S.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 693 - 694
  • [22] Patient specific parametric geometric modelling and finite element analysis of cementless hip prosthesis This paper proposes a framework for subject-specific cementless hip implant design and virtual assembly analysis of the instantiated stem with femur model using finite element method
    George, Subin P.
    Kumar, Gurunathan Saravana
    VIRTUAL AND PHYSICAL PROTOTYPING, 2013, 8 (01) : 65 - 83
  • [23] Effect of Implant Design on Stress Distribution: A Finite Element Study
    Houshmand B.
    Ardakani M.T.
    Moscowchi A.
    Oskoui I.Z.
    Journal of Long-Term Effects of Medical Implants, 2022, 32 (04) : 39 - 45
  • [24] Bone Ingrowth Around an Uncemented Femoral Implant Using Mechanoregulatory Algorithm: A Multiscale Finite Element Analysis
    Mathai, Basil
    Gupta, Sanjay
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [25] Application of probabilistic finite element analysis for crane hook design
    Vinodh, S.
    Ravikumar, R.
    JOURNAL OF ENGINEERING DESIGN AND TECHNOLOGY, 2012, 10 (02) : 255 - 275
  • [26] Finite element analysis of a stemmed hip prosthesis to reduce stress shielding in the proximal femur
    Bliss, Oliver
    Swadener, J. Greg
    Pearce, Gillian
    Zidane, Iham F.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2023, 17 (01) : 9349 - 9359
  • [27] Finite element analysis of mechanical behavior of SMP hip joint implanted in femur bone
    Kulkarni, M.S.
    Sathe, S.R.
    Sharma, K.C.
    Sancheti, K.H.
    Trends in Biomaterials and Artificial Organs, 2009, 23 (01): : 10 - 15
  • [28] Influence of Implant Length, Diameter, and Geometry on Stress Distribution: A Finite Element Analysis
    Anitua, Eduardo
    Tapia, Raul
    Luzuriaga, Felipe
    Orive, Gorka
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2010, 30 (01) : 89 - 95
  • [29] Influence of PEEK Coating on Hip Implant Stress Shielding: A Finite Element Analysis
    Anguiano-Sanchez, Jesica
    Martinez-Romero, Oscar
    Siller, Hector R.
    Diaz-Elizondo, Jose A.
    Flores-Villalba, Eduardo
    Rodriguez, Ciro A.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [30] Probabilistic design of a newly designed cemented hip prosthesis using finite element method
    Kayabasi, Oguz
    Ekici, Bulent
    MATERIALS & DESIGN, 2008, 29 (05) : 963 - 971