Probabilistic finite element analysis of the uncemented hip replacement-effect of femur characteristics and implant design geometry

被引:72
|
作者
Dopico-Gonzalez, Carolina [1 ]
New, Andrew M. [1 ]
Browne, Martin [1 ]
机构
[1] Univ Southampton, Sch Engn Sci, Bioengn Res Grp, Southampton SO9 5NH, Hants, England
关键词
Total hip replacement; Finite element analysis; Probability analysis; HUMAN TRABECULAR BONE; PROXIMAL FEMUR; FEMORAL ANTEVERSION; MECHANICAL-PROPERTIES; COMPUTED-TOMOGRAPHY; FRACTURE PREDICTION; YIELD STRAIN; MODELS; PROSTHESES; STEM;
D O I
10.1016/j.jbiomech.2009.09.039
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In the present study, a probabilistic finite element tool was assessed using an uncemented total hip replacement model. Fully bonded and frictional interfaces were investigated for combinations of three proximal femurs and two implant designs, the Proxima short stem and the IPS hip stem prostheses. The Monte Carlo method was used with two performance indicators: the percentage of bone volume that exceeded specified strain limits and the maximum nodal micromotion. The six degrees of freedom of bone-implant relative position, magnitude of the hip contact force (L), and spatial direction of L were the random variables. The distal portion of the proximal femurs was completely constrained and some of the main muscle forces acting in the hip were applied. The coefficients of the linear approximation between the random variables and the output were used as the sensitivity values. In all cases, bone-implant position related parameters were the most sensitive parameters. The results varied depending on the femur, the implant design and the interface conditions. Values of maximum nodal micromotion agreed with results from previous studies, confirming the robustness of the implemented computational tool. It was demonstrated that results from a single model study should not be generalised to the entire population of femurs and that bone variability is an important factor that should be investigated in such analyses. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:512 / 520
页数:9
相关论文
共 50 条
  • [1] A computational tool for the probabilistic finite element analysis of an uncemented total hip replacement considering variability in bone-implant version angle
    Dopico-Gonzalez, Carolina
    New, Andrew M.
    Browne, Martin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (01) : 1 - 9
  • [2] Probabilistic analysis of an uncemented total hip replacement
    Dopico-Gonzalez, Carolina
    New, Andrew M.
    Browne, Martin
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) : 470 - 476
  • [3] Biomechanical Analysis of Hip Replacement Stem Design: A Finite Element Analysis
    Azbari, Zahra Shamsipour
    Rad, Mohadese Rajaei
    Nahvinejad, Amirreza
    Gilakjani, Hasan Asadi
    Khorsandi, Mohammad
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 305 - 309
  • [4] Musculoskeletal-based finite element analysis of femur after total hip replacement
    Meena, Vijay K.
    Kumar, Mohit
    Pundir, Amit
    Singh, Suman
    Goni, Vijay
    Kalra, Parveen
    Sinha, Ravindra K.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (06) : 553 - 560
  • [5] Mechanics of the canine femur with two types of hip replacement stems - Finite element analysis
    Shahar, R
    Banks-Sills, L
    Eliasy, R
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2003, 16 (03) : 145 - 152
  • [6] Design and Analysis of Customized Hip Implant Using Finite Element Method
    Priya, M. Anu
    Snekhalatha, U.
    Mahalakshmi, R.
    Dhivya, T.
    Gupta, Nilkantha
    ARTIFICIAL INTELLIGENCE AND EVOLUTIONARY COMPUTATIONS IN ENGINEERING SYSTEMS, 2020, 1056 : 515 - 525
  • [7] Effect of the surface geometry of uncemented acetabular cups on primary stability in a model of uncemented total hip replacement in dogs
    Pollet, Valentine
    Viguier, Eric
    Cachon, Thibaut
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2023, 84 (09)
  • [8] Validation of a three dimensional finite element model of a femur with a customized hip implant.
    Couteau, B
    Labey, L
    Hobatho, MC
    Vander Sloten, J
    Arlaud, JY
    Brignola, JC
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 147 - 154
  • [9] Finite element stress analysis of the femur with implant utilizing computed tomography
    Chu, Tai-Ming
    Chag, Wei-Chun
    Linden, Martin
    Robbins, Steven G.
    Biomedical Engineering Applications, Basis Communications, 1997, 9 (01): : 36 - 40
  • [10] Effect of elbow implant design parameters on loosening: A finite element analysis
    Heidari, Milad
    Rahmanivahid, Pooyan
    Sharifi, Sayyed Nabi Al-Din
    Hashemi, Mehdi
    Mohammadian, Erfan
    Akbari, Amir
    Razaviyan, Zahrapanah
    REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2020, 36 (01):