Fixation and Wear With a Contemporary Acetabular Component and Cross-Linked Polyethylene at Minimum 10-Year Follow-Up

被引:24
|
作者
Bedard, Nicholas A. [1 ]
Callaghan, John J. [1 ,2 ]
Stefl, Michael D. [3 ]
Willman, Tyler J. [1 ]
Liu, Steve S. [1 ]
Goetz, Devon D. [4 ]
机构
[1] Univ Iowa, Iowa City, IA USA
[2] VA Med Ctr, Iowa City, IA USA
[3] Univ So Calif, Los Angeles, CA USA
[4] Des Moines Orthopaed Surg, W Des Moines, IA USA
来源
JOURNAL OF ARTHROPLASTY | 2014年 / 29卷 / 10期
关键词
cementless acetabular component; wear; cross-linked polyethylene; outcomes; activity level; TOTAL HIP-ARTHROPLASTY; FEMORAL COMPONENTS; PATIENTS YOUNGER; REPLACEMENT; THA; CHARNLEY; CEMENT; OSTEOARTHRITIS; STEM; AGE;
D O I
10.1016/j.arth.2014.05.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Long term total hip arthroplasty follow-up has demonstrated bearing surface wear and failure of fixation as the major modes of failure. The purpose of this study was to evaluate the minimum 10 year results of a third generation cementless acetabular component using moderately cross-linked polyethylene liners. 150 primary THAs were evaluated clinically for need for revision and activity evaluated using accelerometers, WOMAC, Tegner and UCLA activity-level scores. Radiographs were evaluated for wear, osteolysis and loosening. We compared this cohort to three of our previously reported cohorts. The only revision was unrelated to liner wear and all acetabular components were bone ingrown. There were no cases of acetabular osteolysis and one case of femoral osteolysis. Average steps per year were 1.59 million. Mean steady state wear rate averaged 0.04 mm/year. At 10-years, excellent fixation and low wear were demonstrated using a cementless acetabular construct and moderately cross-linked polyethylene liner. Level of evidence: Therapeutic study, Level III (retrospective comparative study-prospective cohort with historical control). (c) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1961 / 1969
页数:9
相关论文
共 50 条
  • [31] Cementation of Cross-linked Polyethylene Liner Into Well-Fixed Acetabular Shells Mean 6-Year Follow-Up Study
    Wang, Jung-Pan
    Chen, Wei-Ming
    Chen, Cheng-Fong
    Chiang, Chao-Ching
    Huang, Ching-Kuei
    Chen, Tain-Hsiung
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 420 - 424
  • [32] Custom Triflange Acetabular Implants: Average 10-Year Follow-Up
    Meding, John B.
    Meding, Lindsey K.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S201 - S205
  • [33] Crosslinked Polyethylene Demonstrates Substantially Improved Performance at Minimum 10-Year Follow-up Compared to Conventional Polyethylene
    Hopper, Robert H., Jr.
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (03) : 318 - 320
  • [34] 10-YEAR FOLLOW-UP
    MARKOWITZ, NR
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (02): : 177 - 177
  • [35] Ex vivo wear of conventional and cross-linked polyethylene acetabular liners
    Muratoglu, OK
    Wannomae, K
    Christensen, S
    Rubash, HE
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 158 - 164
  • [36] Wear of Third-Generation Cross-Linked Polyethylene in Primary Total Hip Arthroplasty: A 10-Year Analysis
    Jalali, Omid
    Fiske, Joseph
    Dejardin, Michael G.
    Scudday, Travis S.
    Barnett, Steven L.
    Gorab, Robert S.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (05): : 1335 - 1340
  • [37] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty for Osteonecrosis of the Femoral Head: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 526 - 530
  • [39] Proximal row carpectomy: A minimum 10-year follow-up study
    Jebson, PJL
    Hayes, EP
    Engber, WD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2003, 28A (04): : 561 - 569
  • [40] Anterior lumbar interbody fusion - A minimum 10-year follow-up
    Penta, M
    Fraser, RD
    SPINE, 1997, 22 (20) : 2429 - 2434