Custom Triflange Acetabular Implants: Average 10-Year Follow-Up

被引:7
|
作者
Meding, John B. [1 ]
Meding, Lindsey K. [1 ]
机构
[1] Ctr Hip & Knee Surg, 1199 Hadley Rd, Mooresville, IN 46158 USA
来源
JOURNAL OF ARTHROPLASTY | 2023年 / 38卷 / 07期
关键词
triflange acetabular implants; revision total hip arthroplasty; acetabular bone loss; pelvic discontinuity; Paprosky 3A and 3B; TOTAL HIP-ARTHROPLASTY; PELVIC DISCONTINUITY; BONE LOSS; COMPONENTS; RECONSTRUCTION; MANAGEMENT; FIXATION; DEFECTS; CAGES;
D O I
10.1016/j.arth.2023.03.035
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. Methods: Between 2008 and March 2015, 42 revision total hip arthroplasties (41 patients) were performed at our institution with a custom triflange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision total hip arthroplasties was 10 years (range, 6 to 13 years). Results: At the final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of four dislocations necessitating revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. Conclusion: Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S201 / S205
页数:5
相关论文
共 50 条
  • [1] Custom Triflange Acetabular Components for Large Acetabular Defects: Minimum 10-Year Follow-up
    Moore, K. David
    McClenny, Michelle D.
    Wills, Bradley W.
    ORTHOPEDICS, 2018, 41 (03) : E316 - E320
  • [2] Use of constrained acetabular components for hip instability: An average 10-year follow-up study
    Bremner, BRB
    Goetz, DD
    Callaghan, JJ
    Capello, WN
    Johnston, RC
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 131 - 137
  • [3] A 10-year follow-up study of contraceptive Norplant implants
    Du, MK
    Chow, LP
    Zheng, HM
    Chen, CHC
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2000, 68 (03) : 249 - 256
  • [4] 10-YEAR FOLLOW-UP
    MARKOWITZ, NR
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (02): : 177 - 177
  • [5] Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study
    Moon, Jun-Ki
    Ryu, Jaejoon
    Kim, Yeesuk
    Yang, Jae-Hyuk
    Hwang, Kyu-Tae
    Kim, Young-Ho
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2019, 139 (08) : 1149 - 1160
  • [6] Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study
    Jun-Ki Moon
    Jaejoon Ryu
    Yeesuk Kim
    Jae-Hyuk Yang
    Kyu-Tae Hwang
    Young-Ho Kim
    Archives of Orthopaedic and Trauma Surgery, 2019, 139 : 1149 - 1160
  • [7] AZOOR - A 10-year follow-up
    Smith-Hansen, Pia
    Gazieva, Lola
    Ilginis, Tomas
    ACTA OPHTHALMOLOGICA, 2016, 94 (05) : e379 - e380
  • [8] CHYLURIA - 10-YEAR FOLLOW-UP
    YU, HHY
    NGAN, H
    LEONG, CH
    BRITISH JOURNAL OF UROLOGY, 1978, 50 (02): : 126 - 133
  • [9] Bilateral Total Hip and Knee Arthroplasties: Average 10-Year Follow-Up
    Meding, John B.
    Faris, Philip M.
    Davis, Ken E.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3328 - 3332
  • [10] Radial head replacement with a bipolar system: an average 10-year follow-up
    Sershon, Robert A.
    Luchetti, Timothy J.
    Cohen, Mark S.
    Wysocki, Robert W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : E38 - E44