Experimental study on the performance of an epithermal neutron flux monitor for BNCT

被引:14
|
作者
Guan, Xingcai [1 ]
Manabe, Masanobu [2 ]
Tamaki, Shingo [2 ]
Liu, Shuangtong [1 ]
Sato, Fuminobu [2 ]
Murata, Isao [2 ]
Wang, Tieshan [1 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Tianshui South Rd 222, Lanzhou 730000, Gansu, Peoples R China
[2] Osaka Univ, Div Sustainable Energy & Environm Engn, Grad Sch Engn, Yamada Oka 2-1, Suita, Osaka 5650871, Japan
关键词
Epithermal neutron; Neutron flux monitor; BNCT neutron source; OKTAVIAN;
D O I
10.1016/j.apradiso.2016.04.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The performance of an epithermal neutron (0.5 eV < E-n < 10 keV) flux monitor designed for boron neutron capture therapy (BNCT) was experimentally studied by using a prototype monitor in an appropriate neutron field at the intense deuterium-tritium neutron source facility OKTAVIAN of Osaka University, Japan. It was convinced from the experimental results that the developed monitor worked well and the epithermal neutron fluxes in BNCT neutron sources can be measured within 5% by the monitor. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [31] Rhodium self-powered neutron detector as a suitable on-line thermal neutron flux monitor in BNCT treatments
    Miller, Marcelo E.
    Sztejnberg, Manuel L.
    Gonzalez, Sara J.
    Thorp, Silvia I.
    Longhino, Juan M.
    Estryk, Guillermo
    MEDICAL PHYSICS, 2011, 38 (12) : 6502 - 6512
  • [32] Energy optimization of epithermal neutron beams for accelerator-based BNCT
    Bisceglie, E
    Colangelo, P
    Colonna, N
    Maggipinto, G
    Paticchio, V
    Raso, G
    Santorelli, P
    Variale, V
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 523 - 528
  • [33] Simulation study of accelerator based quasi-mono-energetic epithermal neutron beams for BNCT
    Adib, M.
    Habib, N.
    Bashter, I. I.
    El-Mesiry, M. S.
    Mansy, M. S.
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 98 - 102
  • [34] Determination of an RBE for an epithermal neutron beam for BNCT from microdosimetric measurements
    Green, S
    Gainey, M
    Wojnecki, C
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1181 - 1185
  • [35] MCNP design of thermal and epithermal neutron beam for BNCT at the Isfahan MNSR
    Monshizadeh, M.
    Kasesaz, Y.
    Khalafi, H.
    Hamidi, S.
    PROGRESS IN NUCLEAR ENERGY, 2015, 83 : 427 - 432
  • [36] Effective dose evaluation for BNCT treatment in the epithermal neutron beam at THOR
    Wang, J. N.
    Huang, C. K.
    Tsai, W. C.
    Liu, Y. H.
    Jiang, S. H.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1850 - 1853
  • [37] Intercomparison of three epithermal neutron-based clinical trials of BNCT
    Hideghéty, K
    Sauerwein, W
    Busse, P
    Harling, O
    Zamenhof, R
    Chanana, A
    Coderre, J
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 99 - 103
  • [38] Performance evaluation of a 71Ga(n,γ)72Ga reaction-based epithermal neutron flux detector at an AB-BNCT device
    Guan, Xingcai
    Wu, Huangxin
    Bai, Rui
    Wu, Guanghua
    Yang, Wenliang
    Guo, Wuliang
    Wang, Haixi
    Wang, Yongquan
    Du, Junliang
    Zhang, Lu
    Gu, Long
    APPLIED RADIATION AND ISOTOPES, 2024, 207
  • [39] FAST-NEUTRON AND EPITHERMAL-NEUTRON FLUX MEASUREMENT
    LAVI, N
    FISHELZON, Z
    NUCLEAR INSTRUMENTS & METHODS, 1974, 116 (01): : 123 - 124
  • [40] Performance testing of the neutron flux monitors from 10 keV to 1 MeV developed for BNCT: A preliminary study
    Guan, Xingcai
    Manabe, Masanobu
    Tamaki, Shingo
    Sato, Fuminobu
    Murata, Isao
    Wang, Tieshan
    APPLIED RADIATION AND ISOTOPES, 2017, 125 : 119 - 123