Experimental study on the performance of an epithermal neutron flux monitor for BNCT

被引:14
|
作者
Guan, Xingcai [1 ]
Manabe, Masanobu [2 ]
Tamaki, Shingo [2 ]
Liu, Shuangtong [1 ]
Sato, Fuminobu [2 ]
Murata, Isao [2 ]
Wang, Tieshan [1 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Tianshui South Rd 222, Lanzhou 730000, Gansu, Peoples R China
[2] Osaka Univ, Div Sustainable Energy & Environm Engn, Grad Sch Engn, Yamada Oka 2-1, Suita, Osaka 5650871, Japan
关键词
Epithermal neutron; Neutron flux monitor; BNCT neutron source; OKTAVIAN;
D O I
10.1016/j.apradiso.2016.04.003
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The performance of an epithermal neutron (0.5 eV < E-n < 10 keV) flux monitor designed for boron neutron capture therapy (BNCT) was experimentally studied by using a prototype monitor in an appropriate neutron field at the intense deuterium-tritium neutron source facility OKTAVIAN of Osaka University, Japan. It was convinced from the experimental results that the developed monitor worked well and the epithermal neutron fluxes in BNCT neutron sources can be measured within 5% by the monitor. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [21] Monte Carlo study of the beam shaping assembly optimization for providing high epithermal neutron flux for BNCT based on D–T neutron generator
    Shuang Hang
    Xiaobin Tang
    Diyun Shu
    Yuanhao Liu
    Changran Geng
    Chunhui Gong
    Haiyan Yu
    Da Chen
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 310 : 1289 - 1298
  • [22] MCNP study for epithermal neutron irradiation of an isolated liver at the Finnish BNCT facility
    Kotiluoto, P
    Auterinen, I
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 781 - 785
  • [23] BNCT EPITHERMAL NEUTRON BEAM MAPPING BY USING INDIRECT NEUTRON RADIOGRAPHY
    Liu, Yuan-Hao
    Huang, Chun-Kai
    Tsai, Pi-En
    Chen, Ang-Yu
    Liu, Hong-Ming
    Lee, Shih-Chung
    Jiang, Shiang-Huei
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 354 - 358
  • [24] Performance improvement of neutron flux monitor at KSTAR
    Kim, Y. -K.
    Lee, S. -K.
    Kang, B. -H.
    Son, J. -B.
    Kim, G. -D.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [25] Monte Carlo study of the beam shaping assembly optimization for providing high epithermal neutron flux for BNCT based on D-T neutron generator
    Hang, Shuang
    Tang, Xiaobin
    Shu, Diyun
    Liu, Yuanhao
    Geng, Changran
    Gong, Chunhui
    Yu, Haiyan
    Chen, Da
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 310 (03) : 1289 - 1298
  • [26] Effects of neutron collimation, beam size, and spectrum on in-phantom performance of realistic epithermal neutron beams for BNCT
    Kiger, WS
    Sakamoto, S
    Harling, K
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1187 - 1193
  • [27] Proton accelerator-based epithermal neutron beams for BNCT
    Palamara, F
    Mattioda, F
    Varone, R
    Giusti, V
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 283 - 288
  • [28] Feasibility of an epithermal neutron source for BNCT based on RFQ accelerator
    Terlizzi, R
    Colonna, N
    Bisceglie, E
    Colangelo, P
    Marrone, S
    Rainò, A
    Tagliente, G
    Variale, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 210 - 213
  • [29] Experimental investigation of filtered epithermal photoneutron beams for BNCT
    Nigg, DW
    Mitchell, HE
    Harker, YD
    Harmon, JF
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A477 - A482
  • [30] MISMATCH OF THERMAL AND EPITHERMAL NEUTRON FLUX
    CADY, KB
    KIROUAC, GJ
    MCINERNE.JJ
    NUCLEAR SCIENCE AND ENGINEERING, 1967, 29 (02) : 299 - &