A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams

被引:12
|
作者
Pinto, M. [1 ]
Pimpinella, M. [1 ]
Quini, M. [1 ]
D'Arienzo, M. [1 ]
Astefanoaei, I. [2 ]
Loreti, S. [3 ]
Guerra, A. S. [1 ]
机构
[1] Ctr Ric ENEA Casaccia, Ist Nazl Metrol Radiaz Ionizzanti, Via Anguillarese 301, I-00123 Rome, Italy
[2] Al I Cuza Iasi Univ, Fac Phys, Carpath Ctr, 1 Carol I Blvd, RO-700506 Iasi, Romania
[3] Ctr Ric ENEA Frascati, Dipartimento Fus & Tecnol Sicurezza Nucl, Lab Tecnol Nucl, Via E Fermi 45, I-00044 Frascati, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 04期
关键词
graphite calorimetry; calorimetry; medium-energy x-rays; reference dosimetry; primary standard; x-ray dosimetry; HEAT DEFECT; IONIZATION CHAMBERS; LNE-LNHB; DOSIMETRY; KV; UNCERTAINTIES; ABSORPTION; RADIATION; STANDARDS;
D O I
10.1088/0031-9155/61/4/1738
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI) has designed and built a graphite calorimeter that, in a water phantom, has allowed the determination of the absorbed dose to water in medium-energy x-rays with generating voltages from 180 to 250 kV. The new standard is a miniaturized three-bodies calorimeter, with a disc-shaped core of 21 mm diameter and 2 mm thickness weighing 1.134 g, sealed in a PMMA waterproof envelope with air-evacuated gaps. The measured absorbed dose to graphite is converted into absorbed dose to water by means of an energy-dependent conversion factor obtained from Monte Carlo simulations. Heat-transfer correction factors were determined by FEM calculations. At a source-to-detector distance of 100 cm, a depth in water of 2 g cm(-2), and at a dose rate of about 0.15 Gy min(-1), results of calorimetric measurements of absorbed dose to water, D-w, were compared to experimental determinations, D-wK, obtained via an ionization chamber calibrated in terms of air kerma, according to established dosimetry protocols. The combined standard uncertainty of D-w and D-wK were estimated as 1.9% and 1.7%, respectively. The two absorbed dose to water determinations were in agreement within 1%, well below the stated measurement uncertainties. Advancements are in progress to extend the measurement capability of the new in-water-phantom graphite calorimeter to other filtered medium-energy x-ray qualities and to reduce the D-w uncertainty to around 1%. The new calorimeter represents the first implementation of in-water-phantom graphite calorimetry in the kilovoltage range and, allowing independent determinations of D-w, it will contribute to establish a robust system of absorbed dose to water primary standards for medium-energy x-ray beams.
引用
收藏
页码:1738 / 1764
页数:27
相关论文
共 50 条
  • [31] Calorimetric determination of the absorbed dose to water for medium-energy x-rays with generating voltages from 70 to 280 kV
    Krauss, A.
    Bueermann, L.
    Kramer, H-M
    Selbach, H-J
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (19): : 6245 - 6268
  • [32] Investigation of an absorbed dose to water formalism for a miniature low-energy x-ray source
    Watson, Peter
    Seuntjens, Jan
    MEDICAL PHYSICS, 2016, 43 (08) : 4960 - 4960
  • [33] Impact of X-ray energy on absorbed dose assessed with Monte Carlo simulations in a mouse tumor and in nearest organs irradiated with kilovoltage X-ray beams
    Hamdi, M.
    Mimi, M.
    Bentourkia, M.
    CANCER RADIOTHERAPIE, 2017, 21 (03): : 190 - 198
  • [34] CENTAURUS X-3 - NEW LOW-ENERGY AND MEDIUM-ENERGY X-RAY OBSERVATIONS
    LONG, K
    AGRAWAL, PC
    GARMIRE, G
    ASTROPHYSICAL JOURNAL, 1975, 197 (02): : L57 - L59
  • [35] Dependence of overall correction factor of a cylindrical ionization chamber on field size and depth in medium-energy x-ray beams
    Seuntjens, J
    Verhaegen, F
    MEDICAL PHYSICS, 1996, 23 (10) : 1789 - 1796
  • [36] Feasibility of the kQQ0 formalism for Farmer-type chambers in medium-energy kV x-ray beams
    Pinto, M.
    Pimpinella, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S705 - S705
  • [37] The medium-energy concentrator spectrometer on board the BeppoSAX X-ray astronomy satellite
    Boella, G
    Chiappetti, L
    Conti, G
    Cusumano, G
    DelSordo, S
    LaRosa, G
    Maccarone, MC
    Mineo, T
    Molendi, S
    Re, S
    Sacco, B
    Tripiciano, M
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1997, 122 (02): : 327 - 340
  • [38] PORTABLE CALORIMETER FOR X-RAY MEASUREMENTS OF FLUENCE AND FRONT SURFACE DOSE SIMULTANEOUSLY
    WOOD, DS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (06): : 908 - &
  • [39] VARIATIONS IN IONOMETRIC DOSE MEASUREMENTS IN HIGH-ENERGY X-RAY AND ELECTRON-BEAMS
    HOLT, JG
    FLEISCHMAN, RC
    BUFFA, A
    MEDICAL PHYSICS, 1981, 8 (04) : 560 - 561
  • [40] REPORT OF THE IPSM WORKING PARTY ON LOW-ENERGY AND MEDIUM-ENERGY X-RAY DOSIMETRY
    不详
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (08): : 1027 - 1038