Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data

被引:0
|
作者
Werling, A [1 ]
Bublitz, O [1 ]
Doll, J [1 ]
Adam, LE [1 ]
Brix, G [1 ]
机构
[1] German Canc Res Ctr, D-6900 Heidelberg, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In positron emission tomography (PET), scatter correction is generally performed prior to image reconstruction using a more or less exact model of the scatter processes. Those models require estimates of the correct emission and attenuation distribution in the imaged object, neglecting the fact that these estimates already contain scattered events, since they are computed from uncorrected data. The purpose of this work was to bypass this problem by incorporating scatter characteristics directly into the process of iterative image reconstruction. This could be achieved by an optimized implementation of the Single Scatter Simulation (SSS) algorithm which results in a significant speedup of the scatter estimation procedure. The scatter simulation was then included into the forward projection step of maximum likelihood image reconstruction. Results demonstrate that this approach leads to a more exact estimation of the scatter component which can not be obtained by a simple sequential data processing strategy.
引用
收藏
页码:1158 / 1162
页数:3
相关论文
共 50 条
  • [21] High-resolution image reconstruction and its fast algorithm
    Pei, Shengwei
    Du, Minghui
    INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE FOR MODELLING, CONTROL & AUTOMATION JOINTLY WITH INTERNATIONAL CONFERENCE ON INTELLIGENT AGENTS, WEB TECHNOLOGIES & INTERNET COMMERCE, VOL 1, PROCEEDINGS, 2006, : 8 - +
  • [23] LINEAR-ARRAY IMPLEMENTATION OF THE EM ALGORITHM FOR PET IMAGE-RECONSTRUCTION
    RAJAN, K
    PATNAIK, LM
    RAMAKRISHNA, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1439 - 1444
  • [24] Fast Iterative Algorithm for the Reconstruction of Multishot Non-Cartesian Diffusion Data
    Mani, Merry
    Jacob, Mathews
    Magnotta, Vincent
    Zhong, Jianhui
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 1086 - 1094
  • [25] High throughput CUDA implementation of accurate geometric modelling for iterative reconstruction of PET data
    Markiewicz, P. J.
    Thielemans, K.
    Ehrhardt, M. J.
    Jiao, J.
    Burgos, N.
    Atkinson, D.
    Arridge, S. R.
    Hutton, B. F.
    Ourselin, S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [26] Improvements in Image Quality When Using Patient Outline Constraints with a Generalized Scatter PET Reconstruction Algorithm
    Sun, Hongyan
    Pistorius, Stephen
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3083 - 3089
  • [27] Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction
    Doll, J
    Zaers, J
    Trojan, H
    Bellemann, ME
    Adam, LE
    Haberkorn, U
    Brix, G
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1998, 37 (02): : 62 - 67
  • [28] Iterative PET image reconstruction using cascaded data consistency generative adversarial network
    Du, Qianqian
    Ren, Xueting
    Wang, Jiawen
    Qiang, Yan
    Yang, Xiaotang
    Kazihise, Ntikurako Guy-Fernand
    IET IMAGE PROCESSING, 2020, 14 (15) : 3989 - 3999
  • [29] Attenuation and scatter correction of list-mode data driven iterative and analytic image reconstruction algorithms for rotating 3D PET systems
    Reader, AJ
    Erlandsson, K
    Ott, RJ
    Flower, MA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2218 - 2226
  • [30] Iterative multiresolution algorithm for image reconstruction from the magnitude of its Fourier transform
    Rabadi, WA
    Myler, HR
    Weeks, AR
    OPTICAL ENGINEERING, 1996, 35 (04) : 1015 - 1024