Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction

被引:0
|
作者
Doll, J [1 ]
Zaers, J [1 ]
Trojan, H [1 ]
Bellemann, ME [1 ]
Adam, LE [1 ]
Haberkorn, U [1 ]
Brix, G [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Forsch Schwerpunkt Radiol Diagnost & Therapie, D-69120 Heidelberg, Germany
来源
NUKLEARMEDIZIN-NUCLEAR MEDICINE | 1998年 / 37卷 / 02期
关键词
positron emission tomography; 3D data acquisition; iterative image reconstruction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the recent past, several algorithms have been developed in order to transform 3D sinograms acquired at volume PET systems into 2D data sets. These methods offer the possibility to combine the high sensitivity of the 3D measurement with the advantages of iterative 2D image reconstruction. The purpose of our study was the assessment of this approach by using phantom measurements and patient examinations. Methods: The experiments were performed at the latest-generation whole-body PET system ECAT EXACT HR(+). For 2D data acquisition, a collimator of thin tungsten septa was positioned in the field-of-view. Prior to image reconstruction, the measured 3D data were sorted into 2D sinograms by using the Fourier rebinning (FORE) algorithm developed by M. Defrise. The standard filtered backprojection (FBP) method and an optimized ML/EM algorithm with overrelaxation for accelerated convergence were employed for image reconstruction, The spatial resolution of both methods as well as the convergence and noise properties of the ML/EM algorithm were studied in phantom measurements. Furthermore, patient data were acquired in the 2D mode as well as in the 3D mode and reconstructed with both techniques. Results: At the same spatial resolution, the WL/EM-reconstructed images showed fewer and less prominent artefacts than the FBP-reconstructed images. The resulting improved detail conspicuousy was achieved for the data acquired in the 2D mode as well as in the 3D mode. The best image quality was obtained by iterative 2D reconstruction of 3D data sets which were previously rebinned into 2D sinograms with help of the FORE algorithm. The phantom measurements revealed that 50 iteration steps with the optimized ML/EM algorithm were sufficient to keep the relative quantitation error below 5%. Conclusion: Our measurements show that the image quality in 3D PET can be improved by using iterative reconstruction.techniques. The concept of 3D data acquisition and combining the FORE algorithm with 2D ML/EM reconstruction can readily be employed in clinical practice since the computation time is not considerably longer than that in iterative reconstruction of true 2D data.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 50 条
  • [1] Fast iterative image reconstruction of 3D PET data
    Kinahan, PE
    Michel, C
    Defrise, M
    Townsend, DW
    Sibomana, M
    Lonneux, M
    Newport, DF
    Luketich, JD
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1918 - 1922
  • [2] Model-based normalization for iterative 3D PET image reconstruction
    Bai, B
    Li, Q
    Holdsworth, CH
    Asma, E
    Tai, YC
    Chatziioannou, A
    Leahy, RM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2773 - 2784
  • [3] Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction
    Oliver S. Grosser
    Christian Wybranski
    Dennis Kupitz
    Maciej Powerski
    Konrad Mohnike
    Maciej Pech
    Holger Amthauer
    Jens Ricke
    [J]. European Radiology, 2017, 27 : 3625 - 3634
  • [4] Improvement of image quality and dose management in CT fluoroscopy by iterative 3D image reconstruction
    Grosser, Oliver S.
    Wybranski, Christian
    Kupitz, Dennis
    Powerski, Maciej
    Mohnike, Konrad
    Pech, Maciej
    Amthauer, Holger
    Ricke, Jens
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (09) : 3625 - 3634
  • [5] Direct 3D PET Image Reconstruction into MR Image Space
    Gravel, Paul
    Verhaeghe, Jeroen
    Reader, Andrew J.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3955 - 3962
  • [6] A fully 3D iterative image reconstruction algorithm incorporatin data corrections
    Iatrou, M
    Ross, SG
    Manjeshwar, RM
    Stearns, CW
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2493 - 2497
  • [7] Image compression for quality 3D reconstruction
    Salih, Omar M.
    Rasheed, Mohammed H.
    Siddeq, Mohammed M.
    Rodrigues, Marcos A.
    [J]. JOURNAL OF KING SAUD UNIVERSITY-COMPUTER AND INFORMATION SCIENCES, 2022, 34 (05) : 2271 - 2287
  • [8] From 2D PET to 3D PET: Issues of Data Representation and Image Reconstruction
    Gundlich, Brigitte
    Musmann, Patrick
    Weber, Simone
    Nix, Oliver
    Semmler, Wolfhard
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (01): : 31 - 46
  • [9] 3D Image Acquisition and Reconstruction Explained with Online Animations
    Kesner, A.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3699 - 3699
  • [10] High Speed Image Acquisition System for 3D Reconstruction
    Hu, Yanlang
    Li, Ying
    Zhang, Yanning
    Zhou, Quan
    Liu, Juanni
    Wei, Jiayuan
    [J]. ELEVENTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING (ICGIP 2019), 2020, 11373