Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis

被引:106
|
作者
Jorba-Garcia, Adria [1 ]
Gonzalez-Barnadas, Albert [1 ,2 ]
Camps-Font, Octavi [1 ,2 ]
Figueiredo, Rui [1 ,2 ,3 ]
Valmaseda-Castellon, Eduard [1 ,2 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Barcelona, Spain
[2] IDIBELL Inst, Barcelona, Spain
[3] Univ Barcelona UB, Fac Med & Ciencies Salut, Campus Bellvitge,2a Planta,Despatx 2-9, E-08907 Barcelona, Spain
关键词
Dynamic computer-assisted surgery; Navigation systems; Computer-guided implantology; Dental implants; NAVIGATION SYSTEM; DENTAL IMPLANTS; SURGICAL COMPLICATIONS; AUGMENTED REALITY; CLINICAL-TRIAL; SURGERY; DENTISTRY; GUIDE; EXPERIENCE; FRAME;
D O I
10.1007/s00784-021-03833-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To assess the accuracy of dynamic computer-aided implant surgery (dCAIS) systems when used to place dental implants and to compare its accuracy with static computer-aided implant surgery (sCAIS) systems and freehand implant placement. Materials and Methods An electronic search was made to identify all relevant studies reporting on the accuracy of dCAIS systems for dental implant placement. The following PICO question was developed: "In patients or artificial models, is dental implant placement accuracy higher when dCAIS systems are used in comparison with sCAIS systems or with freehand placement? The main outcome variable was angular deviation between the central axes of the planned and final position of the implant. The data were extracted in descriptive tables, and a meta-analysis of single means was performed in order to estimate the deviations for each variable using a random-effects model. Results Out of 904 potential articles, the 24 selected assessed 9 different dynamic navigation systems. The mean angular and entry 3D global deviations for clinical studies were 3.68 degrees (95% CI: 3.61 to 3.74; I-2 = 99.4%) and 1.03 mm (95% CI: 1.01 to 1.04; I-2 = 82.4%), respectively. Lower deviation values were reported in in vitro studies (mean angular deviation of 2.01 degrees (95% CI: 1.95 to 2.07; I-2 = 99.1%) and mean entry 3D global deviation of 0.46 mm (95% CI: 0.44 to 0.48 ; I-2 = 98.5%). No significant differences were found between the different dCAIS systems. These systems were significantly more accurate than sCAIS systems (mean difference (MD): -0.86 degrees; 95% CI: -1.35 to -0.36) and freehand implant placement (MD: -4.33 degrees; 95% CI: -5.40 to -3.25). Conclusion dCAIS systems allow highly accurate implant placement with a mean angular of less than 4 degrees. However, a 2-mm safety margin should be applied, since deviations of more than 1 mm were observed. dCAIS systems increase the implant placement accuracy when compared with freehand implant placement and also seem to slightly decrease the angular deviation in comparison with sCAIS systems.
引用
收藏
页码:2479 / 2494
页数:16
相关论文
共 50 条
  • [41] Accuracy of a Computer-Aided Implant Surgical Technique
    Cassetta, Michele
    Stefanelli, Luigi V.
    Giansanti, Matteo
    Di Mambro, Alfonso
    Calasso, Sabrina
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2013, 33 (03) : 317 - 326
  • [42] Advancing accuracy in guided implant placement: A comprehensive meta-analysis Meta-Analysis evaluation of the accuracy of available implant placement Methods
    Takacs, Anna
    Hardi, Eszter
    Cavalcante, Bianca Golzio Navarro
    Szabo, Bence
    Kispelyi, Barbara
    Joob-Fancsaly, Arpad
    Mikulas, Krisztina
    Varga, Gabor
    Hegyi, Peter
    Kivovics, Marton
    JOURNAL OF DENTISTRY, 2023, 139
  • [43] Accuracy of computer-aided image analysis in the diagnosis of odontogenic cysts: A systematic review
    Vieira Bittencout, Marcos Alan
    de Sa Mafra, Pedro Henrique
    Julia, Roxanne Silva
    Nassif Travencolo, Bruno Augusto
    Jayme Silva, Pedro Urquiza
    Blumenberg, Cauane
    dos Santos Silva, Virginia Kelma
    Paranhos, Luiz Renato
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2021, 26 (03): : E368 - E378
  • [44] Influence of clinical and technical parameters on accuracy of guided implant placement. Systematic review and meta-analysis
    Kasradze, D.
    Segalyte, E.
    Kubilius, R.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 198 - 219
  • [45] The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis
    Putra, Ramadhan Hardani
    Yoda, Nobuhiro
    Astuti, Eha Renwi
    Sasaki, Keiichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (01) : 29 - 39
  • [46] Computer-aided manufacturing technologies for guided implant placement
    Neugebauer, Joerg
    Stachulla, Gerhard
    Ritter, Lutz
    Dreiseidler, Timo
    Mischkowski, Robert A.
    Keeve, Erwin
    Zoeller, Joachim E.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (01) : 113 - 129
  • [47] Computer-Aided Diagnosis of Gastrointestinal Protruded Lesions Using Wireless Capsule Endoscopy: A Systematic Review and Diagnostic Test Accuracy Meta-Analysis
    Kim, Hye Jin
    Gong, Eun Jeong
    Bang, Chang Seok
    Lee, Jae Jun
    Suk, Ki Tae
    Baik, Gwang Ho
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (04):
  • [48] Computer-Aided Diagnosis of Gastrointestinal Ulcer and Hemorrhage Using Wireless Capsule Endoscopy: Systematic Review and Diagnostic Test Accuracy Meta-analysis
    Bang, Chang Seok
    Lee, Jae Jun
    Baik, Gwang Ho
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (12)
  • [49] Three-Dimensional Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery: A Systematic Review
    Lo Russo, Lucio
    Pierluigi, Mariani
    Zhurakivska, Khrystyna
    Digregorio, Chiara
    Lo Muzio, Eleonora
    Laino, Luigi
    PROSTHESIS, 2023, 5 (03): : 809 - 825
  • [50] Immediate implant placement in compromised sockets: A systematic review and meta-analysis
    Amid, Reza
    Kadkhodazadeh, Mahdi
    Moscowchi, Anahita
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (03): : 307 - 317