Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis

被引:106
|
作者
Jorba-Garcia, Adria [1 ]
Gonzalez-Barnadas, Albert [1 ,2 ]
Camps-Font, Octavi [1 ,2 ]
Figueiredo, Rui [1 ,2 ,3 ]
Valmaseda-Castellon, Eduard [1 ,2 ]
机构
[1] Univ Barcelona, Fac Med & Hlth Sci, Barcelona, Spain
[2] IDIBELL Inst, Barcelona, Spain
[3] Univ Barcelona UB, Fac Med & Ciencies Salut, Campus Bellvitge,2a Planta,Despatx 2-9, E-08907 Barcelona, Spain
关键词
Dynamic computer-assisted surgery; Navigation systems; Computer-guided implantology; Dental implants; NAVIGATION SYSTEM; DENTAL IMPLANTS; SURGICAL COMPLICATIONS; AUGMENTED REALITY; CLINICAL-TRIAL; SURGERY; DENTISTRY; GUIDE; EXPERIENCE; FRAME;
D O I
10.1007/s00784-021-03833-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To assess the accuracy of dynamic computer-aided implant surgery (dCAIS) systems when used to place dental implants and to compare its accuracy with static computer-aided implant surgery (sCAIS) systems and freehand implant placement. Materials and Methods An electronic search was made to identify all relevant studies reporting on the accuracy of dCAIS systems for dental implant placement. The following PICO question was developed: "In patients or artificial models, is dental implant placement accuracy higher when dCAIS systems are used in comparison with sCAIS systems or with freehand placement? The main outcome variable was angular deviation between the central axes of the planned and final position of the implant. The data were extracted in descriptive tables, and a meta-analysis of single means was performed in order to estimate the deviations for each variable using a random-effects model. Results Out of 904 potential articles, the 24 selected assessed 9 different dynamic navigation systems. The mean angular and entry 3D global deviations for clinical studies were 3.68 degrees (95% CI: 3.61 to 3.74; I-2 = 99.4%) and 1.03 mm (95% CI: 1.01 to 1.04; I-2 = 82.4%), respectively. Lower deviation values were reported in in vitro studies (mean angular deviation of 2.01 degrees (95% CI: 1.95 to 2.07; I-2 = 99.1%) and mean entry 3D global deviation of 0.46 mm (95% CI: 0.44 to 0.48 ; I-2 = 98.5%). No significant differences were found between the different dCAIS systems. These systems were significantly more accurate than sCAIS systems (mean difference (MD): -0.86 degrees; 95% CI: -1.35 to -0.36) and freehand implant placement (MD: -4.33 degrees; 95% CI: -5.40 to -3.25). Conclusion dCAIS systems allow highly accurate implant placement with a mean angular of less than 4 degrees. However, a 2-mm safety margin should be applied, since deviations of more than 1 mm were observed. dCAIS systems increase the implant placement accuracy when compared with freehand implant placement and also seem to slightly decrease the angular deviation in comparison with sCAIS systems.
引用
收藏
页码:2479 / 2494
页数:16
相关论文
共 50 条
  • [31] Computer-aided detection mammography for breast cancer screening: systematic review and meta-analysis
    Noble, Meredith
    Bruening, Wendy
    Uhl, Stacey
    Schoelles, Karen
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2009, 279 (06) : 881 - 890
  • [32] Computer-aided diagnosis of esophageal cancer and neoplasms in endoscopic images: a systematic review and meta-analysis of diagnostic test accuracy
    Bang, Chang Seok
    Lee, Jae Jun
    Baik, Gwang Ho
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (05) : 1006 - +
  • [33] Computer-Aided Diagnosis of Diminutive Colorectal Polyps in Endoscopic Images: Systematic Review and Meta-analysis of Diagnostic Test Accuracy
    Bang, Chang Seok
    Lee, Jae Jun
    Baik, Gwang Ho
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (08)
  • [34] Diagnostic Accuracy of Artificial Intelligence and Computer-Aided Diagnosis for the Detection and Characterization of Colorectal Polyps: Systematic Review and Meta-analysis
    Nazarian, Scarlet
    Glover, Ben
    Ashrafian, Hutan
    Darzi, Ara
    Teare, Julian
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (07)
  • [35] Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies
    Bover-Ramos, Fernando
    Vina-Almunia, Jose
    Cervera-Ballester, Juan
    Penarrocha-Diago, Miguel
    Garcia-Mira, Berta
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 101 - 115
  • [36] Computer-aided diagnosis in predicting the invasion depth of early colorectal cancer: a systematic review and meta-analysis of diagnostic test accuracy
    Jiawei Bai
    Kai Liu
    Li Gao
    Xin Zhao
    Shaohua Zhu
    Ying Han
    Zhiguo Liu
    Surgical Endoscopy, 2023, 37 : 6627 - 6639
  • [37] Computer-aided diagnosis in predicting the invasion depth of early colorectal cancer: a systematic review and meta-analysis of diagnostic test accuracy
    Bai, Jiawei
    Liu, Kai
    Gao, Li
    Zhao, Xin
    Zhu, Shaohua
    Han, Ying
    Liu, Zhiguo
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (09): : 6627 - 6639
  • [38] Diagnostic Accuracy of Computer-Aided Detection During Active Case Finding for Pulmonary Tuberculosis in Africa: A Systematic Review and Meta-analysis
    Scott, Alex J.
    Perumal, Tahlia
    Hohlfeld, Ameer
    Oelofse, Suzette
    Kuehn, Louie
    Swanepoel, Jeremi
    Geric, Coralie
    Ahmad Khan, Faiz
    Esmail, Aliasgar
    Ochodo, Eleanor
    Engel, Mark
    Dheda, Keertan
    OPEN FORUM INFECTIOUS DISEASES, 2024, 11 (02):
  • [39] Computer-aided technology for fabricating removable partial denture frameworks: A systematic review and meta-analysis
    Pordeus, Mariana Domingues
    Santiago, Joel Ferreira
    Venante, Helena Sandrini
    da Costa, Rodrigo Moreira Bringel
    Chocano, Ana Paula Chappuis
    Porto, Vinicius Carvalho
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 331 - 340
  • [40] Accuracy Comparison between Robot-Assisted Dental Implant Placement and Static/Dynamic Computer-Assisted Implant Surgery: A Systematic Review and Meta-Analysis of In Vitro Studies
    Jain, Saurabh
    Sayed, Mohammed E.
    Ibraheem, Wael I.
    Ageeli, Abrar A.
    Gandhi, Sumir
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqarni, Hatem
    Alshehri, Abdullah Hasan
    Huthan, Halah Mohammed
    Alami, Atheer
    Al Wadei, Mohammed Hussain Dafer
    Aljabri, Yahya
    MEDICINA-LITHUANIA, 2024, 60 (01):