Energy Conservation Opportunities in an Industrial Boiler System

被引:18
|
作者
Kaya, Durmus [1 ]
Eyidogan, Muharrem [2 ]
机构
[1] Energy Syst & Environm Res Inst, TUBITAK MRC, TR-41470 Gebze, Turkey
[2] Kocaeli Univ, Dept Mech Educ, TR-41380 Kocaeli, Turkey
来源
JOURNAL OF ENERGY ENGINEERING-ASCE | 2010年 / 136卷 / 01期
关键词
Steam boiler; Energy efficiency; Energy savings; Exergy analysis;
D O I
10.1061/(ASCE)0733-9402(2010)136:1(18)
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, an experimental study has been performed for a natural gas fueled boiler operating at 42,000-kPa pressure and 713.15-K temperature with a nominal capacity of 33.33 kg/s to find improvement in the boiler efficiency. Temperature, pressure, velocity, and gas emissions measurements have been made and energy, mass balances, and exergy analysis have been formed. Then, efficiency of boiler, potential energy saving options and saving quantities, investment costs, and payback period for normal operating conditions have been calculated. From the measured data, the boiler and exergetic efficiency were calculated as 88.28 and 36.7%, respectively. It is seen that the main efficiency losses are leakage of air in the rotary type air heaters, operation of the boiler at high excess air/fuel ratios, operation of the boiler under the rated load, surface thermal losses, and high flue gas temperatures. The largest part of the boiler efficiency losses is due to the air leakage in the rotary type air heater. Due to air leakages, the load of the induced-draft fan increases and prevents the boiler to reach its normal boiler capacity. It has been calculated that if air leakage in rotary type air heater is reduced to acceptable limits (10%) in practice, boiler steam production capacity will be increased by 34.2% from 24.44 to 32.8 kg/s. Implementation cost is required only for reducing air leakages in the rotary type air heater and surface thermal losses. The investment cost for reducing air leakage in the rotary type air heater to the acceptable limits (10%) is between $600,000 and $700,000. Under these circumstances, the payback period of this investment cost is about 15 months.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 50 条
  • [21] Opportunities for energy conservation in existing hospitals
    Dussault, Joseph
    Nelson, Jack
    [J]. Engineered Systems, 2014, 31 (06): : 44 - 53
  • [22] OPPORTUNITIES AND STRATEGIES FOR ENERGY-CONSERVATION
    BORETSKY, M
    [J]. TECHNOLOGY REVIEW, 1977, 79 (08): : 56 - 62
  • [23] Energy conservation opportunities in the textile industry
    Lazic, Branislava
    Popovic, Biljana
    [J]. TEKSTIL, 2011, 60 (12): : 659 - 665
  • [24] DEVELOPMENT OF THE CHILLED WATER SYSTEM ANALYSIS TOOL FOR ASSESSING ENERGY CONSERVATION OPPORTUNITIES
    Gaudani, Ghanshyam
    Quintal, Alex
    Kosanovic, Dragoljub
    [J]. PROCEEDINGS OF THE ASME 7TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2013, 2014,
  • [25] CONSERVING ENERGY IN INDUSTRIAL BOILER WATER-SYSTEMS
    BEARDSLEY, ML
    [J]. PLANT ENGINEERING, 1983, 37 (19) : 68 - 70
  • [26] Scheduling and energy - Industrial challenges and opportunities
    Merkert, Lennart
    Harjunkoski, Iiro
    Isaksson, Alf
    Saynevirta, Simo
    Saarela, Antti
    Sand, Guido
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2015, 72 : 183 - 198
  • [27] A few problems related to boiler in energy conservation design standard
    Fang, XM
    Zhang, WJ
    Wang, W
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 653 - 659
  • [28] Conservation of energy: Industrial pumping systems
    Joshi, Prakash
    [J]. Chemical Engineering World, 2002, 37 (12): : 148 - 150
  • [29] Energy conservation in industrial refrigeration systems
    Briley, GC
    [J]. ASHRAE JOURNAL, 2003, 45 (06) : 46 - 47
  • [30] INDUSTRIAL POLICY ON ENERGY-CONSERVATION
    LUCKMAN, CG
    [J]. CIM BULLETIN, 1977, 70 (779): : 98 - 98