DEVELOPMENT OF THE CHILLED WATER SYSTEM ANALYSIS TOOL FOR ASSESSING ENERGY CONSERVATION OPPORTUNITIES

被引:0
|
作者
Gaudani, Ghanshyam [1 ]
Quintal, Alex [1 ]
Kosanovic, Dragoljub [1 ]
机构
[1] Univ Massachusetts, Dept Mech & Ind Engn, Ind Assessment Ctr, Amherst, MA 01003 USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Chilled water systems constitute a major portion of energy consumption in air conditioning systems of the large buildings and process cooling of the manufacturing plants. These systems do not operate optimally in most of the cases because of the operating parameters set and/or the components used. The Chilled water system analysis tool software (CWSAT) is developed as a primary screening tool for energy evaluation. This tool quantifies the energy usage of the various chilled water systems and typical measures that can be applied to these systems to conserve energy. The tool requires minimum number of inputs to analyze the component-wise energy consumption and incurred overall cost. Both air-cooled and water-cooled systems can be analyzed with this tool; however, this paper focuses on water-cooled systems. The tool uses weather data of the chilled water system location and loading schedules to calculate the chilled water system energy consumption. The Air-Conditioning and Refrigeration Institute (ARI) standard 550/590 typical loading schedule is also incorporated for the chiller(s) loading. The tool is capable of comparing economics by analyzing the energy consumption and relevant cost of the existing system and the new system with cost reduction opportunities considered like: (1) increase chilled water temperature set point, (2) lowering the condenser cooing water supply temperature set point, (3) replace chiller(s), (4) Apply variable speed control to chilled and/or condenser water pumps, (5) upgrade cooling tower fan speed control, (6) Use free cooling when possible for water-cooled systems. The savings can be calculated separately for each cost reduction opportunity or can be combined. The economics comparison can be a primary decision criterion for further detailed engineering and cost analysis related with system changes. The comparison between actual system energy consumption and CWSAT results are also shown.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] ENERGY-CONSERVATION WITH CHILLED-WATER STORAGE
    FIORINO, D
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1993, 35 (05): : 22 - &
  • [2] ENERGY-CONSERVATION IN HOT AND CHILLED WATER-SYSTEMS
    RISHEL, JB
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (05): : 59 - 59
  • [3] Analysis on energy-saving of natural cooling chilled water system
    Fang, Zhen
    Hu, Chuntao
    Liu, Qian
    He, Ping
    [J]. 2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 289 - 294
  • [4] Energy analysis for retrofit of chilled water plants
    Anzoategui, FJ
    [J]. ENERGY ENGINEERING, 1996, 93 (02) : 12 - 29
  • [5] Experimental study on energy conservation of variable chilled water temperature with DDC
    Zhou, Cong
    Zou, Hong
    Chen, Jianbo
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1389 - 1396
  • [6] Energy Conservation Opportunities in an Industrial Boiler System
    Kaya, Durmus
    Eyidogan, Muharrem
    [J]. JOURNAL OF ENERGY ENGINEERING-ASCE, 2010, 136 (01): : 18 - 25
  • [7] Energy analysis of chilled water system configurations using simulation-based optimization
    Ali, Muzaffar
    Vukovic, Vladimir
    Sahir, Mukhtar Hussain
    Fontanella, Giuliano
    [J]. ENERGY AND BUILDINGS, 2013, 59 : 111 - 122
  • [8] Energy analysis and conservation opportunities in spray dryers
    Patel, S. K.
    Bade, M. H.
    [J]. IDS'2018: 21ST INTERNATIONAL DRYING SYMPOSIUM, 2018, : 139 - 146
  • [9] Energy audit and analysis of chilled water system for air conditioning of commercial buildings in Shanghai
    Wang, CQ
    Long, WD
    Ding, WT
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 123 - 127
  • [10] Wind energy development and wildlife conservation: Challenges and opportunities
    Kuvlesky, William P., Jr.
    Brennan, Leonard A.
    Morrison, Michael L.
    Boydston, Kathy K.
    Ballard, Bart M.
    Bryant, Fred C.
    [J]. JOURNAL OF WILDLIFE MANAGEMENT, 2007, 71 (08): : 2487 - 2498