DEVELOPMENT OF THE CHILLED WATER SYSTEM ANALYSIS TOOL FOR ASSESSING ENERGY CONSERVATION OPPORTUNITIES

被引:0
|
作者
Gaudani, Ghanshyam [1 ]
Quintal, Alex [1 ]
Kosanovic, Dragoljub [1 ]
机构
[1] Univ Massachusetts, Dept Mech & Ind Engn, Ind Assessment Ctr, Amherst, MA 01003 USA
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Chilled water systems constitute a major portion of energy consumption in air conditioning systems of the large buildings and process cooling of the manufacturing plants. These systems do not operate optimally in most of the cases because of the operating parameters set and/or the components used. The Chilled water system analysis tool software (CWSAT) is developed as a primary screening tool for energy evaluation. This tool quantifies the energy usage of the various chilled water systems and typical measures that can be applied to these systems to conserve energy. The tool requires minimum number of inputs to analyze the component-wise energy consumption and incurred overall cost. Both air-cooled and water-cooled systems can be analyzed with this tool; however, this paper focuses on water-cooled systems. The tool uses weather data of the chilled water system location and loading schedules to calculate the chilled water system energy consumption. The Air-Conditioning and Refrigeration Institute (ARI) standard 550/590 typical loading schedule is also incorporated for the chiller(s) loading. The tool is capable of comparing economics by analyzing the energy consumption and relevant cost of the existing system and the new system with cost reduction opportunities considered like: (1) increase chilled water temperature set point, (2) lowering the condenser cooing water supply temperature set point, (3) replace chiller(s), (4) Apply variable speed control to chilled and/or condenser water pumps, (5) upgrade cooling tower fan speed control, (6) Use free cooling when possible for water-cooled systems. The savings can be calculated separately for each cost reduction opportunity or can be combined. The economics comparison can be a primary decision criterion for further detailed engineering and cost analysis related with system changes. The comparison between actual system energy consumption and CWSAT results are also shown.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Energy Efficiency Analysis of All-Variable Chilled Water based Air-Conditioning System
    Beniwal, Ravi
    Srivastava, Prateek
    [J]. INTERNATIONAL CONFERENCE ON TRENDS IN MATERIAL SCIENCE AND INVENTIVE MATERIALS (ICTMIM 2020), 2020, 2259
  • [22] Performance analysis of a chilled water system with various pumping schemes
    Tirmizi, Syed A.
    Gandhidasan, P.
    Zubair, Syed M.
    [J]. APPLIED ENERGY, 2012, 100 : 238 - 248
  • [23] Thermoeconomic and thermoenvironmental analysis of the chilled water system in a shopping mall
    Abreu, Renata Portela
    Correia, Victor Hugo Lobo
    Lourenco, Atilio Barbosa
    Marques, Adriano da Silva
    Carvalho, Monica
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 134 : 304 - 311
  • [24] The chilled water storage analysis for a university building cooling system
    Boonnasa, Somkiat
    Namprakai, Pichai
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (11-12) : 1396 - 1408
  • [25] Research on energy saving control of chilled water system of central air conditioning system
    Ju, Li Zhuang
    Cai, Lv
    Jie, Mei
    [J]. PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 2875 - 2878
  • [26] Assessing Energy Performance and Environmental Impact of Low GWP Vapor Compression Chilled Water Systems
    Mansouri, Rami
    Bisulandu, Baby-Jean Robert Mungyeko
    Ilinca, Adrian
    [J]. ENERGIES, 2023, 16 (12)
  • [27] DEVELOPMENT OF SELF-ASSESSMENT TOOL FOR ENERGY-CONSERVATION
    SAXENA, U
    MODEPALLE, R
    [J]. ENERGY ENGINEERING, 1994, 91 (03) : 57 - 65
  • [28] Energy Performance and Controllability Study of Different Control Strategies in Chilled Water System
    Li, Dan
    Nie, Jinzhe
    Li, Deying
    Zhang, Shuai
    [J]. 10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 650 - 657
  • [29] A chilled-water thermal energy storage system in a high rise building
    Yu, H
    Watanabe, T
    Akashi, Y
    Nishiyama, N
    Cui, J
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 502 - 507
  • [30] Energy use and economic comparison of chilled-water pumping system alternatives
    Bahnfleth, William P.
    Peyer, Eric B.
    [J]. ASHRAE TRANSACTIONS 2006, VOL 112, PT 2, 2006, 112 : 198 - +