Field measurement of U-value using multiple sensors at test chamber and EIFS building

被引:1
|
作者
Sang-Tae, No [1 ]
Jeong, Jae-Weon [2 ]
机构
[1] Korea Natl Univ Transportat, Sch Architecture, Chungju, South Korea
[2] Hanyang Univ, Dept Architectural Engn, Seoul, South Korea
关键词
Heat flux sensor; U-value; Chamber test; EIFS;
D O I
10.1080/13467581.2019.1596810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study is to analyse the heat flux difference and examine applicability of the heat flux sensor along with various sensor attachment methods. Using multiple sensors and various tapes, a KS F 2278 thermal test was performed in hot/cold chamber conditions with standard panel specimen. The measured heat flux values of sensors were stable. But values of sensors were smaller than the heat flux result of KS F 2278. Thus, thermal resistance of attachment tape on a sensor should be considered during on site U-value measuring process. This study also examined the differences between measured U-value and design U-value by attaching the different sensors in the same area using multiple heat flux sensors. All cases are shown to the same patterns on each heat flux and U-value graph, but U-values with regard to various sensors have shown some differences to the designed values. Using in-situ measurement, the EIFS wall was found to be difficult to measure accurately due to the small level of heat flux.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [1] Studying the impacts of test condition and nonoptimal positioning of the sensors on the accuracy of the in-situ U-value measurement
    Mobaraki, Behnam
    Pascual, Francisco Javier Castilla
    Garcia, Arturo Martinez
    Mascaraque, Miguel Angel Mellado
    Vazquez, Borja Frutos
    Alonso, Carmen
    HELIYON, 2023, 9 (07)
  • [2] Simulation-based comparative analysis of U-value of field measurement methods
    Kim, Seon-In
    Choi, Jae-Sol
    Jo, Jae-Hun
    Joe, Jaewan
    Cho, Young-Hum
    Kim, Eui-Jong
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 50
  • [3] In situ U-value measurement of building envelopes through continuous low-cost monitoring
    Mobaraki, Behnam
    Pascual, Francisco Javier Castilla
    Lozano-Galant, Fidel
    Lozano-Galant, Jose Antonio
    Soriano, Rocio Porras
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 43
  • [4] In-situ U-value measurements of typical building envelopes in a severe cold region of China: U-value variations and energy Implications
    Yu, Jiaqi
    Chang, Wen-Shao
    Zhang, Ruinan
    Dong, Yu
    Huang, Haoyu
    Wang, Tsung-Hsien
    ENERGY AND BUILDINGS, 2024, 324
  • [5] Wall assemblies U-value calculation in test buildings using constant power heating
    Ratnieks, Janis
    Jakovics, Andris
    Gendelis, Stanislays
    INTERNATIONAL SCIENTIFIC CONFERENCE ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2018, 2018, 147 : 207 - 213
  • [6] Managing the uncertainty of the U-value measurement using an auxiliary set along with a thermal camera
    Papadakos, Georgios
    Marinakis, Vangelis
    Konstas, Christos
    Doukas, Haris
    Papadopoulos, Agis
    ENERGY AND BUILDINGS, 2021, 242
  • [7] Experimental and numerical study of a novel composite building wall U-value
    Nath, Biswajit
    Roy, Sujit
    Das, Biplab
    Ehyaei, M. A.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 53
  • [8] Analysis of Window Components Affecting U-Value Using Thermal Transmittance Test Results and Multiple Linear Regression Analysis
    No, Sang-Tae
    Seo, Jun-Sik
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [9] U-value in situ measurement for energy diagnosis of existing buildings
    Ficco, Giorgio
    Iannetta, Fabio
    Ianniello, Elvira
    Alfano, Francesca Romana d'Ambrosio
    Dell'Isola, Marco
    ENERGY AND BUILDINGS, 2015, 104 : 108 - 121
  • [10] A New Method of Pixel-Level In Situ U-Value Measurement for Building Envelopes Based on Infrared Thermography
    Wang, Zihao
    Hou, Yu
    Soibelman, Lucio
    COMPUTING IN CIVIL ENGINEERING 2023-RESILIENCE, SAFETY, AND SUSTAINABILITY, 2024, : 697 - 704