Simulation-based comparative analysis of U-value of field measurement methods

被引:2
|
作者
Kim, Seon-In [1 ]
Choi, Jae-Sol [1 ]
Jo, Jae-Hun [1 ]
Joe, Jaewan [1 ]
Cho, Young-Hum [2 ]
Kim, Eui-Jong [1 ]
机构
[1] Inha Univ, Dept Architectural Engn, Incheon 22212, South Korea
[2] Yeungnam Univ, Sch Architecture, Gyongsan 38541, South Korea
基金
新加坡国家研究基金会;
关键词
Thermal transmittance (U-value); Building envelope; In-situ measurements; Heat flux meter (HFM); Infrared thermography (IRT); INFRARED THERMOGRAPHY; THERMAL PERFORMANCE; BUILDINGS; DIAGNOSIS;
D O I
10.1016/j.csite.2023.103433
中图分类号
O414.1 [热力学];
学科分类号
摘要
Accurate analysis of building energy performance necessitates methodologies that can diagnose the thermal performance of a building's envelope. The building envelope contains various uncertainties and poses difficulties in verifying the measurement results, making it crucial to ensure the reliability of the measurement method. This study used dynamic simulations to verify the accuracy and reproducibility of commonly used field measurement methods. The simulation data were applied to the heat flux meter (HFM) and infrared thermography (IRT) methods to calculate the thermal transmittance of the building envelope and confirm their suitability as a field measurement method. According to the accuracy verification results, the HFM and indoor IRT (IRTi) methods, which are less affected by the external environment, evaluated the actual thermal performance of the wall close to the theoretical value with average relative errors of 3.3% and 4.2%, respectively. In the reproducibility evaluation, the HFM method exhibited similar levels of deviation over time. Additionally, to reduce the deviation in the reproducibility of the thermal transmittance derived from the IRT method, the average method was applied for data analysis, leading to a decrease in the reproducibility deviation from 36.5% to 13.3% for IRTi and from 107.3% to 71.8% for IRT outdoors (IRTo).
引用
收藏
页数:13
相关论文
共 50 条
  • [1] An Analysis of U-Value as a Measure of Variability
    Xiuyan Kong
    James S. McEwan
    Lewis A. Bizo
    T. Mary Foster
    The Psychological Record, 2017, 67 : 581 - 586
  • [2] An Analysis of U-Value as a Measure of Variability
    Kong, Xiuyan
    McEwan, James S.
    Bizo, Lewis A.
    Foster, T. Mary
    PSYCHOLOGICAL RECORD, 2017, 67 (04): : 581 - 586
  • [3] Field measurement of U-value using multiple sensors at test chamber and EIFS building
    Sang-Tae, No
    Jeong, Jae-Weon
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2019, 18 (02) : 63 - 71
  • [4] U-value in situ measurement for energy diagnosis of existing buildings
    Ficco, Giorgio
    Iannetta, Fabio
    Ianniello, Elvira
    Alfano, Francesca Romana d'Ambrosio
    Dell'Isola, Marco
    ENERGY AND BUILDINGS, 2015, 104 : 108 - 121
  • [5] Dynamic U-value estimation and energy simulation for green roofs
    Kotsiris, G.
    Androutsopoulos, A.
    Polychroni, E.
    Nektarios, P. A.
    ENERGY AND BUILDINGS, 2012, 45 : 240 - 249
  • [6] In situ measurement of fa ades with a low U-value: Avoiding deviations
    Gaspar, Katia
    Casals, Miquel
    Gangolells, Marta
    ENERGY AND BUILDINGS, 2018, 170 : 61 - 73
  • [7] Calculation and comparative analysis of thermal transmittance (U-value) of Scottish houses from recent centuries
    Rezvani, Fahimeh
    Zabalza Bribian, Ignacio
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (07) : 873 - 886
  • [8] In situ measurement of the effect of facade greening on the U-value of the exterior wall
    Alsaad, Hayder
    Engelhardt, Miriam
    Voelker, Conrad
    BAUPHYSIK, 2022, 44 (04) : 211 - 219
  • [9] A comparison of standardized calculation methods for in situ measurements of facades U-value
    Gaspar, Katia
    Casals, Miquel
    Gangolells, Marta
    ENERGY AND BUILDINGS, 2016, 130 : 592 - 599
  • [10] Comparative study of simulation and experimentation for the U-value of double-glazed windows with inter-pane blinds
    Sharda, Anuranjan
    Kumar, Sudhir