Field measurement of U-value using multiple sensors at test chamber and EIFS building

被引:1
|
作者
Sang-Tae, No [1 ]
Jeong, Jae-Weon [2 ]
机构
[1] Korea Natl Univ Transportat, Sch Architecture, Chungju, South Korea
[2] Hanyang Univ, Dept Architectural Engn, Seoul, South Korea
关键词
Heat flux sensor; U-value; Chamber test; EIFS;
D O I
10.1080/13467581.2019.1596810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this study is to analyse the heat flux difference and examine applicability of the heat flux sensor along with various sensor attachment methods. Using multiple sensors and various tapes, a KS F 2278 thermal test was performed in hot/cold chamber conditions with standard panel specimen. The measured heat flux values of sensors were stable. But values of sensors were smaller than the heat flux result of KS F 2278. Thus, thermal resistance of attachment tape on a sensor should be considered during on site U-value measuring process. This study also examined the differences between measured U-value and design U-value by attaching the different sensors in the same area using multiple heat flux sensors. All cases are shown to the same patterns on each heat flux and U-value graph, but U-values with regard to various sensors have shown some differences to the designed values. Using in-situ measurement, the EIFS wall was found to be difficult to measure accurately due to the small level of heat flux.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 50 条
  • [41] Performance Evaluation of a Guarded Hot Box U-value Measurement Facility under Different Software Based Temperature Control Strategies
    Ghosh, Amrita
    Ghosh, Supratik
    Neogi, Subhasis
    4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 : 448 - 454
  • [42] Automated data-processing technique: 2D Map for identifying the distribution of the U-value in building elements by quantitative internal thermography
    Tejedor, Blanca
    Barreira, Eva
    Almeida, Ricardo M. S. F.
    Casals, Miquel
    AUTOMATION IN CONSTRUCTION, 2021, 122
  • [43] Application of the Heat Flow Meter Method and Extended Average Method to Improve the Accuracy of In Situ U-Value Estimations of Highly Insulated Building Walls
    Lee, Ye-Ji
    Moon, Ji-Hoon
    Choi, Doo-Sung
    Ko, Myeong-Jin
    SUSTAINABILITY, 2024, 16 (13)
  • [44] Long-Range Wireless System for U-Value Assessment Using a Low-Cost Heat Flux Sensor
    Lazaro, Marc
    Lazaro, Antonio
    Gonzalez, Benito
    Villarino, Ramon
    Girbau, David
    SENSORS, 2022, 22 (19)
  • [45] Reference Value Measurement Algorithms for PMU Field Test and Calibration
    Xu S.
    Liu H.
    Bi T.
    Lao Y.
    Liu, Hao (hliu@ncepu.edu.cn), 1600, Chinese Society for Electrical Engineering (40): : 3452 - 3461
  • [46] RCS Measurement Accuracy in the U/VHF Range: Measurement of the Electromagnetic Field Decrease Rate in an Indoor Anechoic Chamber
    Massaloux, P.
    Maze-Merceur, G.
    2013 7TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2013, : 3322 - 3324
  • [47] Vibration measurement of a steel building with viscoelastic dampers using acceleration sensors
    Li, Liang
    Ohkubo, Takaaki
    Matsumoto, Shinya
    MEASUREMENT, 2021, 171
  • [48] Vibration measurement of SRC office building using MEMS acceleration sensors
    Hamamoto T.
    Choi J.
    Tomioka A.
    AIJ Journal of Technology and Design, 2019, 25 (60) : 731 - 734
  • [49] Detection of people and tracking test bed using multiple sensors
    Yamazaki, Tatsuya
    Kayama, Kentaro
    Igi, Seiji
    MUE: 2007 INTERNATIONAL CONFERENCE ON MULTIMEDIA AND UBIQUITOUS ENGINEERING, PROCEEDINGS, 2007, : 135 - 140
  • [50] A 3D RFID Static Test System Using a Spherical Near-Field Antenna Measurement Chamber
    Lee, Yuan-Hung
    Tsai, Meng-Ying
    Yang, Chang-Fa
    Lin, Ike
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2013, 61 (01) : 362 - 370