Using Body Mass Index to Predict Needle Length in Fluoroscopy-Guided Lumbar Punctures

被引:10
|
作者
Nayate, A. P. [1 ]
Nasrallah, I. M. [1 ]
Schmitt, J. E. [1 ]
Mohan, S. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Div Neuroradiol, 3400 Spruce St,110 Donner Bldg, Philadelphia, PA 19104 USA
关键词
COMPUTED-TOMOGRAPHY; OBESITY; DISTANCE; SPACE; SKIN;
D O I
10.3174/ajnr.A4579
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The authors evaluated patients who underwent oblique interlaminar-approach fluoroscopy-guided lumbar punctures and had cross-sectional imaging of the lumbar spine within 1 year of the lumbar puncture to devise a formula for the appropriate needle length based on BMI. They determined the formula to predict the needle length as Skin-Canal Distance (inches) = 0.077 x BMI + 0.88. BACKGROUND AND PURPOSE: Predicting the appropriate needle length to use in oblique interlaminar-approach fluoroscopy-guided lumbar punctures in patients with a large body mass index is difficult. Using the wrong needle length can lead to an increased radiation dose and patient discomfort. We hypothesized that body mass index could help determine the appropriate needle length to use in patients. MATERIALS AND METHODS: We randomly selected patients who underwent oblique interlaminar-approach fluoroscopy-guided lumbar punctures and had cross-sectional imaging of the lumbar spine within 1 year of imaging (n = 50). The distance from the skin to the midlumbar spinal canal (skin-canal distance) at the level of the lumbar puncture was measured by using an oblique angle of 8.6 degrees, which is an average of angles most often used to perform the procedure. A formula was devised using the skin-canal distance and body mass index to predict the appropriate needle length, subsequently confirmed in 45 patients. RESULTS: The body mass index and skin-canal distance were significantly higher (P < .001) in patients who underwent fluoroscopy-guided lumbar puncture with 5- or 7-inch needles (n = 22) than in patients requiring 3.5-inch needles (n = 28). Using linear regression, we determined the formula to predict the needle length as Skin-Canal Distance (inches) = 0.077 x Body Mass Index + 0.88. We found a strong correlation (P < .001) between the predicted and actual skin canal distance in 45 patients, and our formula better predicted the skin-canal distance than others. CONCLUSIONS: We designed a formula that uses body mass index to predict the appropriate needle length in oblique interlaminar-approach fluoroscopy-guided lumbar punctures and validated it by demonstrating a strong correlation between the predicted and actual skin-canal distance.
引用
收藏
页码:572 / 578
页数:7
相关论文
共 50 条
  • [41] Efficacy of Fluoroscopy-Guided Cutting Needle Lung Biopsy in Patients with Diffuse Infiltrative Lung Disease
    Choi, Soo Jeon
    Shin, Eun Ah
    Kim, Joung Sook
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2011, 70 (01) : 43 - 50
  • [42] Optimal Angle of Needle Insertion for Fluoroscopy-Guided Transforaminal Epidural Injection of L5
    Ra, In-Hoo
    Min, Woo-Kie
    PAIN PRACTICE, 2015, 15 (05) : 393 - 399
  • [43] Fluoroscopy-Guided Lumbar Drainage of Cerebrospinal Fluid for Patients in Whom a Blind Beside Approach Is Difficult
    Chee, Choong Guen
    Lee, Guen Young
    Lee, Joon Woo
    Lee, Eugene
    Kang, Heung Sik
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (04) : 860 - 865
  • [44] Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy
    Cheung, Joo Yeon
    Kim, Yookyung
    Shim, Sung Shine
    Lim, Soo Mee
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (01) : 89 - 96
  • [45] Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections
    Viola, Ronald J.
    Nguyen, Giao B.
    Yoshizumi, Terry T.
    Stinnett, Sandra S.
    Hoang, Jenny K.
    Kranz, Peter G.
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (05) : 525 - 532
  • [46] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Nicola Rotolo
    Chiara Floridi
    Andrea Imperatori
    Federico Fontana
    Anna Maria Ierardi
    Monica Mangini
    Veronica Arlant
    Giuseppe De Marchi
    Raffaele Novario
    Lorenzo Dominioni
    Carlo Fugazzola
    Gianpaolo Carrafiello
    European Radiology, 2016, 26 : 381 - 389
  • [47] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Rotolo, Nicola
    Floridi, Chiara
    Imperatori, Andrea
    Fontana, Federico
    Ierardi, Anna Maria
    Mangini, Monica
    Arlant, Veronica
    De Marchi, Giuseppe
    Novario, Raffaele
    Dominioni, Lorenzo
    Fugazzola, Carlo
    Carrafiello, Gianpaolo
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 381 - 389
  • [48] Fluoroscopy-Guided Metallic Foreign Body Removal: A Report of Three Cases and Literature Review
    AlBilasi, Thamer M.
    AlDhawi, Lama F.
    AlOlaywi, Ahmed N.
    Al Mutairy, Alyaa S.
    AlGhamdi, Fareed R.
    Alamry, Saleh S.
    AlZhrani, Hatem A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (06)
  • [49] Simple Fluoroscopy-Guided Transforaminal Lumbar Puncture: Safety and Effectiveness of a Coaxial Curved-Needle Technique in Patients with Spinal Muscular Atrophy and Complex Spines
    Jacobson, J. P.
    Cristiano, B. C.
    Hoss, D. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (01) : 183 - 188
  • [50] Fluoroscopy-Guided Transfacet Lumbar Epidural Steroid Injection for Symptomatic Synovial Cyst Treatment: A Case Report
    Al-Saidi, Ibrahim
    Pascoe, Maeve
    Tabbaa, Kutaiba
    A & A PRACTICE, 2020, 14 (11): : e01312