Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

被引:33
|
作者
Cheung, Joo Yeon [1 ]
Kim, Yookyung [1 ]
Shim, Sung Shine [1 ]
Lim, Soo Mee [1 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Sch Med, Seoul 158710, South Korea
关键词
Biopsy; Cone beam CT; Fluoroscopy; Lung; SOLITARY PULMONARY NODULES; ASPIRATION BIOPSY; DIAGNOSTIC-ACCURACY; LUNG NODULES; COMPUTED-TOMOGRAPHY; GUIDANCE; LESIONS; PNEUMOTHORAX; SAFETY; MASSES;
D O I
10.3348/kjr.2011.12.1.89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). Materials and Methods: We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. Results: The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep (>= 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%; group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 +/- 4.0 minutes, 157.1 +/- 76.5 mGy) than in group B (9.0 +/- 3.5 minutes, 21.9 +/- 15.2 mGy) (p < 0.05). Conclusion: Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions (>= 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [1] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Nicola Rotolo
    Chiara Floridi
    Andrea Imperatori
    Federico Fontana
    Anna Maria Ierardi
    Monica Mangini
    Veronica Arlant
    Giuseppe De Marchi
    Raffaele Novario
    Lorenzo Dominioni
    Carlo Fugazzola
    Gianpaolo Carrafiello
    European Radiology, 2016, 26 : 381 - 389
  • [2] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Rotolo, Nicola
    Floridi, Chiara
    Imperatori, Andrea
    Fontana, Federico
    Ierardi, Anna Maria
    Mangini, Monica
    Arlant, Veronica
    De Marchi, Giuseppe
    Novario, Raffaele
    Dominioni, Lorenzo
    Fugazzola, Carlo
    Carrafiello, Gianpaolo
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 381 - 389
  • [3] Multidetector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses
    Strocchi, S.
    Colli, V.
    Conte, L.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 162 - 165
  • [4] Fluoroscopy-Guided Percutaneous Transthoracic Needle Lung Biopsy with the Aid of Planning Cone-Beam CT: Diagnostic Accuracy and Complications
    Cho, Sang Hyun
    Yoon, Hyun Jung
    Lee, Young
    Kim, Injoong
    Gil, Je Ryung
    Kim, Yeo Jin
    DIAGNOSTICS, 2024, 14 (21)
  • [5] C-Arm Cone-Beam CT-Guided Transthoracic Lung Core Needle Biopsy as a Standard Diagnostic Tool An Observational Study
    Jaconi, Marta
    Pagni, Fabio
    Vacirca, Francesco
    Leni, Davide
    Corso, Rocco
    Cortinovis, Diego
    Bidoli, Paolo
    Bono, Francesca
    Cuttin, Maria S.
    Valente, Maria G.
    Pesci, Alberto
    Bedini, Vittorio A.
    Leone, Biagio E.
    MEDICINE, 2015, 94 (12) : e698
  • [6] Cone Beam CT-Guided Endobronchial Biopsy Assisted by Augmented Fluoroscopy
    Pritchett, Michael
    Radaelli, Alessandro
    Schampaert, Stephanie
    van der Bom, Imramsjah
    CHEST, 2017, 152 (04) : 887A - 887A
  • [7] Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT
    Ren, Q.
    Zhou, Y.
    Yan, M.
    Zheng, C.
    Zhou, G.
    Xia, X.
    CLINICAL RADIOLOGY, 2022, 77 (05) : E394 - E399
  • [8] Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety
    Choi, M. J.
    Kim, Y.
    Hong, Y. S.
    Shim, S. S.
    Lim, S. M.
    Lee, J. K.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014): : E182 - E187
  • [9] CT/fluoroscopy-guided transthoracic needle biopsy: Sensitivity and complication rate in 98 procedures
    Muehlstaedt, M
    Bruening, R
    Diebold, J
    Mueller, A
    Helmberger, T
    Reiser, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (02) : 191 - 196
  • [10] C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules
    Hwang, Hye Sun
    Chung, Myung Jin
    Lee, Ju Won
    Shin, Sung Wook
    Lee, Kyung Soo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : W400 - W407