Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

被引:33
|
作者
Cheung, Joo Yeon [1 ]
Kim, Yookyung [1 ]
Shim, Sung Shine [1 ]
Lim, Soo Mee [1 ]
机构
[1] Ewha Womans Univ, Dept Radiol, Sch Med, Seoul 158710, South Korea
关键词
Biopsy; Cone beam CT; Fluoroscopy; Lung; SOLITARY PULMONARY NODULES; ASPIRATION BIOPSY; DIAGNOSTIC-ACCURACY; LUNG NODULES; COMPUTED-TOMOGRAPHY; GUIDANCE; LESIONS; PNEUMOTHORAX; SAFETY; MASSES;
D O I
10.3348/kjr.2011.12.1.89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). Materials and Methods: We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. Results: The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep (>= 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%; group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 +/- 4.0 minutes, 157.1 +/- 76.5 mGy) than in group B (9.0 +/- 3.5 minutes, 21.9 +/- 15.2 mGy) (p < 0.05). Conclusion: Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions (>= 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose.
引用
收藏
页码:89 / 96
页数:8
相关论文
共 50 条
  • [21] Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver
    Cornelis, F.
    Takaki, H.
    Laskhmanan, M.
    Durack, J. C.
    Erinjeri, J. P.
    Getrajdman, G. I.
    Maybody, M.
    Sofocleous, C. T.
    Solomon, S. B.
    Srimathveeravalli, G.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (05) : 1252 - 1260
  • [22] CT fluoroscopy-guided robotically-assisted lung biopsy
    Xu, Sheng
    Fichtinger, Gabor
    Taylor, Russell H.
    Banovac, Filip
    Cleary, Kevin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [23] Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
    Kwang Nam Jin
    Chang Min Park
    Jin Mo Goo
    Hyun Ju Lee
    Youkyung Lee
    Jung Im Kim
    So Young Choi
    Hyo-Cheol Kim
    European Radiology, 2010, 20 : 2108 - 2115
  • [24] Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems
    Jin, Kwang Nam
    Park, Chang Min
    Goo, Jin Mo
    Lee, Hyun Ju
    Lee, Youkyung
    Kim, Jung Im
    Choi, So Young
    Kim, Hyo-Cheol
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2108 - 2115
  • [25] MR fluoroscopy-guided transthoracic fine-needle aspiration biopsy: Feasibilitty
    Sakarya, ME
    Unal, O
    Ozbay, B
    Uzun, K
    Kati, I
    Ozen, S
    Etlik, O
    RADIOLOGY, 2003, 228 (02) : 589 - 592
  • [26] CT-guided transthoracic fine-needle aspiration versus transbronchial fluoroscopy-guided needle aspiration in pulmonary nodules
    Shankar, S
    Gulati, M
    Gupta, D
    Rajwanshi, A
    Suri, S
    ACTA RADIOLOGICA, 1998, 39 (04) : 395 - 399
  • [27] Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy
    Inaba, Yohei
    Hitachi, Shin
    Watanuki, Munenori
    Chida, Koichi
    TOMOGRAPHY, 2022, 8 (01) : 438 - 446
  • [28] CT-guided percutaneous lung biopsy: Comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients
    Grand, David Justin
    Atalay, Michael A.
    Cronan, John J.
    Mayo-Smith, William W.
    Dupuy, Damian E.
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E133 - E136
  • [29] Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules
    Hirose, T
    Mori, K
    Machida, S
    Tominaga, K
    Yokoi, K
    Adachi, M
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2000, 30 (06) : 259 - 262
  • [30] Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications
    Hong, Wonju
    Yoon, Soon Ho
    Goo, Jin Mo
    Park, Chang Min
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (07) : 1203 - 1212